Electrical permit history — 4124 S 6th Av

4124 S 6th Av, Tucson — built 1975, with 77 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

4124 S 6th Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1975 — 1970s commercial stock · last permitted panel/service work 2025 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2025 (1 year ago). The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0425-00804 — Electrical feeder upgrade to two existing 100 Amp panels "panel 8" and"panel 9". (Reference TC-COM-0225-00288 for plan set)
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2025 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2020. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2025. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 3,573 sq ft (county building-footprint layer, 2 structures)
Usable for solar, planning estimate
≈ 2,500 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 30 kW — roughly 80 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 49,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$4,000–$6,500 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 2.8 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
120072150
Year constructed
1975 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Retail Strip Center
Building area
3,276 sq ft
Service on record
City records show the 2025 permit was finalized; the permit description states “Electrical feeder upgrade to two existing 100 Amp panels "panel 8" and"panel 9". (Reference TC-COM-0225-00288 for plan set)” — an increase in capacity as described, not a confirmed installed rating.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permit with evidence of issuance is dated 2025. City records show the permit was finalized. The permit covers only the work described in that record.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permit with evidence of issuance is dated 2025. City records show the permit was finalized. The permit covers only the work described in that record.

What that reading rests on. The issuing offices hold 77 building permits for this parcel dated between 2005 and 2025. By category the work is addition / alteration (28), permanent sign (25), trade permit (17) and row permit - city cip/joc (2). 50 of them carry a final inspection; the other 27 were issued, expired or are still open, which is not the same as work completed. There are 6 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 120072150. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85714 · Commercial & industrial reports · Homes in 85714 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S 6TH AV hold 1,051 City permits on record, 200 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (83 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025recordROW Permit - City CIP/JOCComplete
2025recordRight-of-Way (ROW) Permit - UtilityNeeds Resubmittal
2025TC-COM-0425-00804Commercial Trade PermitComplete
2025TC-COM-0425-00805Commercial Trade PermitComplete
2025TC-COM-0425-00802Commercial Trade PermitComplete
2025TC-COM-0225-00288Commercial Addition/Alteration PermitComplete
2024recordROW Permit - City CIP/JOCInspections
2024TC-COM-1024-01896Commercial Trade PermitComplete
2024CE-VIO0624-02431FireClosed - Resolved
2024TC-COM-0424-00576Commercial Trade PermitIssued
2022T22CM00356Commercial Trade PermitComplete
2021T21CM05374Commercial Trade PermitComplete
2020T20CM04888Commercial Trade PermitComplete
2019T19CM00470Commercial Trade PermitComplete
2018T18CM08936Commercial Trade PermitComplete
2018T18OT01162Commercial New Building PermitCanceled
2017T17CM07782Commercial Addition/Alteration PermitCanceled
2016T16CM01408Residential Trade PermitComplete
2015T15DV09553SIGN VIOLATIONCOMPLIAN
2015T15OT00487Permanent Sign PermitCanceled
2015T15OT00488Permanent Sign PermitCanceled
2012T12OT00979Permanent Sign PermitCanceled
2012T12CM03699Commercial Trade PermitComplete
2012T12DV05170SIGN VIOLATIONCOMPLIAN
2012T12DV05171SIGN VIOLATIONCOMPLIAN
2012T12OT00447Permanent Sign PermitCanceled
2012T12DV01375SIGN VIOLATIONCOMPLIAN
2011T11OT00217Residential Addition/Alteration PermitComplete
2010T10OT01132Commercial Addition/Alteration PermitComplete
2010T09OT00835Commercial Addition/Alteration PermitWithdrawn
2009T09CM02524Commercial Addition/Alteration PermitCanceled
2009T09CM02298Commercial Addition/Alteration PermitWithdrawn
2009T09OT01663Commercial Addition/Alteration PermitComplete
2009T09DV01346COMMERCIAL ZONINGNOVERIFY
2009T09CM00567Commercial Trade PermitWithdrawn
2009C10-03-39 Zoning ComplianceEffectuated
2009T09PRE0010Pre-Application ConferenceCanceled
2009T09OT00498Permanent Sign PermitComplete
2008T08OT02705Commercial Addition/Alteration PermitComplete
2008T08OT02746Commercial Addition/Alteration PermitWithdrawn
2008T08OT02421Commercial Addition/Alteration PermitWithdrawn
2008T08OT02177Commercial Addition/Alteration PermitComplete
2008T08OT00541Commercial Addition/Alteration PermitComplete
2008T08OT00381Permanent Sign PermitComplete
2008T08OT00380Permanent Sign PermitComplete
2008T08OT00095Permanent Sign PermitComplete
2007T07OT02470Permanent Sign PermitComplete
2007T07OT01999Permanent Sign PermitComplete
2007T07OT01887Permanent Sign PermitComplete
2007T07OT01800Commercial Addition/Alteration PermitComplete
2007T07OT01780Commercial Addition/Alteration PermitComplete
2007T07OT01655Permanent Sign PermitComplete
2007T07OT01412Commercial Addition/Alteration PermitCanceled
2007T07OT01284Commercial Addition/Alteration PermitComplete
2007T07OT01162Commercial Addition/Alteration PermitComplete
2007T07OT00801Commercial Addition/Alteration PermitComplete
2007T07DV03089Permanent Sign PermitComplete
2007T07OT00207Commercial Addition/Alteration PermitComplete
2007T07OT00100Commercial Addition/Alteration PermitComplete
2006T06OT02661Commercial Addition/Alteration PermitComplete
2006T06OT02812Permanent Sign PermitComplete
2006T06CM04574Commercial Trade PermitComplete
2006T06CM04579Commercial Trade PermitCanceled
2006T06CM04980Commercial Trade PermitCanceled
2006T06CM04575Commercial Trade PermitWithdrawn
2006T06OT02290Commercial Addition/Alteration PermitComplete
2006T06OT02110Commercial Addition/Alteration PermitWithdrawn
2006T06OT02111Commercial Addition/Alteration PermitWithdrawn
2006T06OT02097Commercial Addition/Alteration PermitWithdrawn
2006T06OT02093Commercial Addition/Alteration PermitWithdrawn
2006T06OT02022Permanent Sign PermitComplete
2006T06OT01708Permanent Sign PermitComplete
2006T06OT01709Permanent Sign PermitComplete
2006T06OT01711Permanent Sign PermitComplete
2006T06OT01703Permanent Sign PermitComplete
2006T06OT01706Permanent Sign PermitComplete
2006T06OT01707Permanent Sign PermitCanceled
2006T06OT01702Permanent Sign PermitComplete
2006T06OT01704Permanent Sign PermitComplete
2006T06OT01705Permanent Sign PermitComplete
2006T06OT01710Permanent Sign PermitComplete
2005T02BU03011GradingCanceled
2005T02CM05501Commercial Addition/Alteration PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 120072150 — 77 City permits on file from 2005 to 2025 and 6 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.