Electrical permit history — 720 W Michigan Dr
720 W Michigan Dr, Tucson — built 1980, with 7 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
720 W Michigan Dr
Built 1980 — 1980s commercial stock · 7 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 720 W Michigan Dr (aztucsonelectricalsolutions.com/property/120022500/720-w-michigan-dr-tucson-az-85714) · Public records last checked 2026-08-16
- Parcel
- 120022500
- Built
- 1980 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-1
- Assessor use
- State School Prop
- Parcel size
- 5.66 acres
- Building area
- 81,146 sq ft (assessor record)
- Sewer
- Connection on file (1972) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 right-of-way (row) - utility permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 right-of-way (row) - utility permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-05-25 (TR-ROW-0526-00644) — The Tucson Police Department will be installing camera systems at 70 locations. An excel spreadsheet has been included with all the locations and pole numbers, as well as, a traffic control plan. TPD will be utilizing a TPD marked vehicle to assist with traffic safety. This permit will serge for streetlight(s): #7829 4232 S 12th Av #7734 598 W Irvington Rd #7837 4602 S 12th Av.
Permit history (7)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-05-25expires 2026-08-31 | TR-ROW-0526-00644City permit record | Right-of-Way (ROW)The Tucson Police Department will be installing camera systems at 70 locations. An excel spreadsheet has been included with all the locations and pole numbers, as well as, a traffic control plan. TPD will be utilizing a TPD marked vehicle to assist with traffic safety. This permit will serge for streetlight(s): #7829 4232 S 12th Av #7734 598 W Irvington Rd #7837 4602 S 12th Av | Issued | |
| 2026-05-14expires 2026-12-05 | TC-COM-0526-00717City permit record | Commercial Building125A MPU Overhead | Issued | |
| 2026-03-19finaled | TR-UTL-0326-00545City permit record | Right-of-Way (ROW) - UtilityFire Hydrant Repair | Complete | |
| 2021-04-16finaled | T21RW01823City permit record | Addition / alterationPOTHOLE AND TRENCH AT VARIOUS LOCATIONS ALONG MICHIGAN ST PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. TARP Project, COT Contract No. 181856, A9 Andrew Klos, 520-837-6685 05/10/2021 - PLAN ADDITION - R1 ADDITIONAL POTHOLING AND TRENCHING ADDED 05/25/2021 - PLAN ADDITION - R2 ADDED MCP FOR DISCHARGING WELL WATER AND START TIME CHANGE TO 5:30AM 06/04/2021 - PLAN ADDITION - R3 ADDED WEEKEND WORK 07/23/2021 - PLAN ADDITION - R4 ASPHALT PATCH WORK 07/29/2021- PLAN ADDITION - R5 REPLACING WATER LINE - JACK AND BORE PIT - POTHOLE AND TRENCHING ALONG MICHIGAN AT VARIOUS LOCATIONS FROM 19TH ST. TO LINDY AVE. - ASPHALT PATCH WORK. APPROXIMATLEY 2000' OF EXCAVATING | Final | |
| 2018-07-17finaled | T18CM05551City permit record | COMBOINSTALL COMMERCIAL PHOTOVOLTAIC SYSTEM AND RELATED MATERIALS | L of c | |
| 2000-03-02finaled | T00EL00532City permit record | ELECTELECTRIC:AIR MONITOR | Final | |
| 1999-12-20finaled | T99CM05882City permit record | COMBOCLASSROOM MODULAR:TD#14-18-46 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (1)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2005-01-25 | T05FR00107Code enforcement case | Code enforcement case | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 120022500 — 7 permits on file from 1999 to 2026 (2 combo, 1 right-of-way (row), 1 commercial building, 1 right-of-way (row) - utility) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
