Electrical permit history — 3386 S 6th Av

3386 S 6th Av, Tucson — built 1961, with 124 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

3386 S 6th Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1961 — 1960s commercial stock · last permitted panel/service work 2008 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2008 (18 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T08EL01723 — ELECTRIC:NEW SERVICE PANEL
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire automatic extinguishing system permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onLast permitted 2010 (16 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T10BU01351 — INSTALL:KITCHEN HOOD FIRE SUPPRESSION SYSTEM
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2008 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2013. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 2010. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2015. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 99,498 sq ft (county building-footprint layer, 3 structures)
Usable for solar, planning estimate
≈ 69,600 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 770 kW — roughly 1,930 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,270,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$102,000–$165,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 2.2 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11901076B
Year constructed
1961 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Community Shop Ctr Open Air
Building area
105,533 sq ft
Service on record
City records show the 2008 permit was finalized; the permit description states “ELECTRIC:NEW SERVICE PANEL ”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permit with evidence of issuance is dated 2025. The work was permitted, but final completion is not confirmed. The permit covers only the work described in that record.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permit with evidence of issuance is dated 2025. The work was permitted, but final completion is not confirmed. The permit covers only the work described in that record.

What that reading rests on. The issuing offices hold 124 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (38), addition / alteration (35), permanent sign (30) and fire automatic extinguishing system (8). 73 of them carry a final inspection; the other 51 were issued, expired or are still open, which is not the same as work completed. There are 5 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11901076B. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85713 · Commercial & industrial reports · Homes in 85713 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S 6TH AV hold 618 City permits on record, 145 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (129 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-COM-1126-01833Commercial Addition/Alteration PermitSubmitted - Online
2026TS-PRM-1126-00394Permanent Sign PermitIn Review
2025TS-PRM-0825-00333Permanent Sign PermitIssued
2025CE-VIO0325-00991RefuseClosed - Resolved
2024TC-COM-0924-01809Commercial Addition/Alteration PermitExpired
2024TS-PRM-0724-00315Permanent Sign PermitExpired
2024CE-VIO0624-02518Code enforcement caseClosed - Resolved
2024CE-VIO0624-02410Code enforcement caseClosed - Resolved
2024recordROW Permit - Development/BuildingComplete
2023TF-FCP-1123-01323Fire Automatic Extinguishing System PermitComplete
2023TS-PRM-0623-00390Permanent Sign PermitIssued
2023TS-PRM-0623-00375Permanent Sign PermitComplete
2023recordROW Permit - Development/BuildingComplete
2023TS-PRM-0223-00168Permanent Sign PermitComplete
2022T22CM02567Commercial Addition/Alteration PermitComplete
2022DP21-0303Development PackageIssued
2022T22OT00520Permanent Sign PermitExpired
2021T21PRE0071Pre-Application ConferenceCanceled
2020T20CM05097Commercial Trade PermitExpired
2019T19OT00054Permanent Sign PermitComplete
2018T18OT00635Permanent Sign PermitExpired
2017T17OT01040Permanent Sign PermitExpired
2017T17SA00169Zoning ComplianceComplete
2017T17CM00110Commercial Addition/Alteration PermitComplete
2016T16CM08047Commercial Addition/Alteration PermitComplete
2016T16CM08046Commercial Addition/Alteration PermitComplete
2016T16OT01341Permanent Sign PermitComplete
2016T16CM07256Commercial Addition/Alteration PermitWithdrawn
2015T15OT01365Permanent Sign PermitComplete
2015T15CM06685Commercial Trade PermitComplete
2015T15BU01089Commercial Fence/Wall PermitWithdrawn
2015T15OT01062Permanent Sign PermitComplete
2015T15DV05885SIGN VIOLATIONCOMPLIAN
2015T15BU00344Commercial Trade PermitComplete
2015T15OT00412Permanent Sign PermitComplete
2015T15OT00027Permanent Sign PermitComplete
2015T14CM07387Commercial Addition/Alteration PermitCanceled
2014T14CM05272Commercial Addition/Alteration PermitComplete
2014T14DV05769WORK WITHOUT PERMITS-COMMERCLNOVERIFY
2013T13CM03815Commercial Trade PermitComplete
2013T13OT00488Permanent Sign PermitCanceled
2013T12CFW0061Special Events Fire Permit - VendorComplete
2013T13CM02208Commercial Addition/Alteration PermitComplete
2012T12CFW0080Special Events Fire Permit - VendorComplete
2012T12CM06743Commercial Trade PermitComplete
2011T11PL01272Commercial Trade PermitWithdrawn
2011T11CFW0101Special Events Fire Permit - VendorCanceled
2011T11SA00152Zoning ComplianceComplete
2011T10CM01801Commercial Addition/Alteration PermitComplete
2010T10CM03454Commercial Addition/Alteration PermitComplete
2010T10PL01607Commercial Trade PermitCanceled
2010T10OT02052Commercial Addition/Alteration PermitComplete
2010T10OT01988Permanent Sign PermitCanceled
2010T10OT01823Permanent Sign PermitCanceled
2010T10OT01759Permanent Sign PermitCanceled
2010T10BU01351Commercial Trade PermitComplete
2010T10OT01760Permanent Sign PermitComplete
2010T10EL01922Commercial Trade PermitCanceled
2010T10CM01732Commercial Trade PermitComplete
2010T10CM00839Commercial Trade PermitComplete
2010T10OT01185Permanent Sign PermitComplete
2010T10CM00844Commercial Addition/Alteration PermitComplete
2010T10CM00845Commercial Addition/Alteration PermitComplete
2010T10CM00846Commercial Addition/Alteration PermitComplete
2010T10OT00913Permanent Sign PermitCanceled
2010T10OT00695Permanent Sign PermitComplete
2010T10CM00829Commercial Addition/Alteration PermitWithdrawn
2010T10OT00527Commercial Addition/Alteration PermitWithdrawn
2010T09OT02369Permanent Sign PermitCanceled
2010T10BU00192Commercial Trade PermitCanceled
2009T09CM03028Commercial Addition/Alteration PermitWithdrawn
2009T09CM01379Commercial Addition/Alteration PermitComplete
2009T09CM01380Commercial Addition/Alteration PermitComplete
2009T09CM01377Commercial Addition/Alteration PermitCanceled
2009T09CM01378Commercial Addition/Alteration PermitCanceled
2009T09BU01592Fire Automatic Extinguishing System PermitComplete
2009T09CM01822Commercial Addition/Alteration PermitComplete
2009T09CM00144Commercial Addition/Alteration PermitCanceled
2009T09OT01009Annual Portable Sign ComplianceCanceled
2009T09BU00483Commercial Addition/Alteration PermitComplete
2009T09BU00321Fire Automatic Extinguishing System PermitComplete
2009T09BU00326Commercial Trade PermitComplete
2009T09BU00318Fire Automatic Extinguishing System PermitComplete
2009T09OT00288Permanent Sign PermitComplete
2009T08CM03466Commercial Addition/Alteration PermitComplete
2008T08CM02990Commercial New Building PermitComplete
2008T08EL01723Commercial Trade PermitComplete
2008T08EL01722Commercial Trade PermitComplete
2008T08BU01437Commercial DemolitionComplete
2008T08EL00534Commercial Trade PermitCanceled
2007T07EL01869Commercial Trade PermitCanceled
2007T07OT02278Permanent Sign PermitComplete
2007T07ME00676Commercial Trade PermitCanceled
2007T07BU00824Fire Automatic Extinguishing System PermitCanceled
2007T07OT01413Permanent Sign PermitComplete
2007T07EL00879Commercial Trade PermitComplete
2007T07CM01238Commercial Addition/Alteration PermitCanceled
2007T07BU00661Fire Automatic Extinguishing System PermitWithdrawn
2007T07EL00500Commercial Trade PermitWithdrawn
2006T06EL02176Commercial Trade PermitWithdrawn
2006T06EL00547Commercial Trade PermitComplete
2004T03CM05368Commercial Addition/Alteration PermitWithdrawn
2004T04BU00934Fire Automatic Extinguishing System PermitComplete
2004T04EL00580Commercial Trade PermitComplete
2003T03BU02373Commercial Trade PermitComplete
2003T03CM04030Commercial Addition/Alteration PermitComplete
2003T03EL00529Commercial Trade PermitWithdrawn
2003T02CM04149Commercial Addition/Alteration PermitWithdrawn
2003T03BU00599Commercial Addition/Alteration PermitWithdrawn
2002T02EL02095Commercial Trade PermitCanceled
2002T02CM02884Commercial Trade PermitWithdrawn
2002T02OT00806Permanent Sign PermitComplete
2002T02OT00666Permanent Sign PermitComplete
2002T02BU01177Fire Automatic Extinguishing System PermitComplete
2002T02CM00444Commercial Addition/Alteration PermitComplete
2002T02EL00317Commercial Trade PermitComplete
2001T01EL02592Commercial Trade PermitComplete
2001T01OT00735Permanent Sign PermitWithdrawn
2001T01EL00594Commercial Trade PermitCanceled
2000T00EL02524Commercial Trade PermitCanceled
2000T00EL00772Commercial Trade PermitComplete
1999T99EL02776Commercial Trade PermitComplete
1999T99OT00053Commercial Addition/Alteration PermitComplete
1999T99EL00360Commercial Trade PermitComplete
1998T98EL01840Commercial Trade PermitComplete
1998T98EL01839Commercial Trade PermitWithdrawn
1998T98EL00341Commercial Trade PermitComplete
1997T97BU02313Commercial Addition/Alteration PermitComplete
1997T97EL01751Commercial Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11901076B — 124 City permits on file from 1997 to 2026 and 5 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-11-13.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.