Electrical permit history — 234 E 22nd St

234 E 22nd St, Tucson — built 1958, with 25 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

234 E 22nd St

Built 1958 — 1950s commercial stock · last permitted panel/service work 2019 (finaled)

Parcel
11812051A
Built
1958 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Restaurant Sit Down
Parcel size
0.29 acres
Building area
4,750 sq ft (assessor record)
Sewer
Connection on file (2005) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2019 permit was finalized; the permit description states “N.492279 & N.492286 Transfer cable attachment, aerial service drops; Install cable tags; Remove old poles.”.

See the property

County aerial photograph centered on 234 E 22nd St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2019 (7 years ago). City inspection record: last recorded inspection 2019-07-08; no approved final is shown. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T19RW02132 — N.492279 & N.492286 Transfer cable attachment, aerial service drops; Install cable tags; Remove old poles.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2008 build permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyLikely dueLast permitted 2004 (22 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T04BU00206 — FIRE SPKR:INSTALL KITCHEN EXHAUST SYSTEM
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

  • Worth confirming

    There is an electrical reconnect permit from 2015. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2000-12-08$500,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2019-04-18 (T19RW02132) — N.492279 & N.492286 Transfer cable attachment, aerial service drops; Install cable tags; Remove old poles..

Permit history (25)

Permit history for this parcel — 8 of 25 records
DateRecordWhatStatusValue
2019-04-18finaledT19RW02132City permit recordROWN.492279 & N.492286 Transfer cable attachment, aerial service drops; Install cable tags; Remove old poles.Final
2018-08-08expired 2019-02-04T18CM06185City permit recordCOMBOOUTDOOR LIGHTING CODEExpired
2017-11-20finaledT17RW05146City permit recordROWEXCAVATE TO INSTALL A NEW 1" SERVICE, IN ASPHALT.Final
2017-10-13finaledT17CM07748City permit recordCOMBORESTAURANTC of o
2017-03-03finaledT17CM01720City permit recordCOMBORETAILC of o
2017-03-03finaledT17CM01722City permit recordCOMBORETAILC of o
2017-03-03finaledT17CM01723City permit recordCOMBOOFFICEC of o
2017-03-03finaledT17CM01725City permit recordCOMBORETAILC of o
Show 17 older records
Permit history for this parcel — remaining 17 records
DateRecordWhatStatusValue
2016-02-26finaledT16EX00583City permit recordEXCAV2 POLE REPLACEMENTS IN ALLEYFinal
2015-06-10finaledT15CM03927City permit recordCOMBORECONNECT ELECTRIC;COMMFinal
2014-06-18expired 2014-12-17T14CM03759City permit recordCOMBOELECTRIC RECONNECTS TO COMMExpired
2010-07-28expired 2011-02-13T10CM02087City permit recordCOMBORELOCATE HAND SINK/INSTALL 2 HAND SINKSClosed
2010-06-22expired 2010-12-19T10BU00993City permit recordBUILDFIRE HOOD SYSTEMClosed
2008-07-15expired 2009-11-30T08OT01693City permit recordC-OF-OC OF O:TORTILLA FACTORYClosed
2008-06-12T08AN00594City permit recordADDRNEWIssued
2008-05-02finaledT08PL00732City permit recordPLUMBRE-ROUTE GAS LINE (COMM)Final
2008-04-08finaledT08BU00681City permit recordBUILDKITCHEN EXHAUST HOOD FIRE SUPPRESSION SYSTEMFinal
2007-09-12finaledT07BU01949City permit recordBUILDEXHAUST HOODFinal
2005-02-15finaledT05OT00347City permit recordSIGNSIGN:8517 LA BUENA MEXICAN FOODFinal
2004-11-01T04AN01045City permit recordADDRNEWIssued
2004-09-14finaledT04OT01821City permit recordSIGNSIGN:7751Final
2004-06-09finaledT04CM02597City permit recordCOMBORESTAURANT & TORTILLA FACTORY / GENREAL REPAIR:FIRE DAMAGE T04VL00171C of o
2004-01-28finaledT04BU00206City permit recordBUILDFIRE SPKR:INSTALL KITCHEN EXHAUST SYSTEMFinal
2004-01-16expired 2004-09-11T04OT00087City permit recordC-OF-OC OF O:RESTAURANT:BAKERYWithdrwn
1999-10-14finaledT99ME01150City permit recordMECHPRESSURE VESSEL CERTIFICATE:TUC-23924,20010Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (10)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 10 records
DateRecordWhatStatus
2025-02-05CE-VIO0225-00534Code enforcement caseCode enforcement caseClosed - resolved
2015-07-14T15DV05089Code enforcement caseRefuseComplian
2014-11-05T14DV09234Code enforcement caseVegetationCourtcmp
2013-03-04T13DV01237Code enforcement caseRefuseComplian
2012-08-15T12DV07160Code enforcement caseVegetationNoverify
2011-03-24finaledT11FR00699Code enforcement caseFireComplete
2010-01-08finaledT10FR00044Code enforcement caseFireComplete
2006-04-18finaledT06FR00815Code enforcement caseCode enforcement caseComplete
Show 2 older records
Code enforcement history for this parcel — remaining 2 records
DateRecordWhatStatus
2004-10-29T04ZV00797Code enforcement caseCode enforcement caseComplian
2004-03-30T04VL00171Code enforcement caseFireComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11812051A — 25 permits on file from 1999 to 2019 (10 combo, 4 build, 2 row, 2 c-of-o) and 10 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).