Electrical permit history — 88 E Broadway Bl

88 E Broadway Bl, Tucson — built 2009, with 76 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

88 E Broadway Bl

Build year not published — permits on file from 2009 · last permitted panel/service work 2025 (permitted, completion not confirmed)

Parcel
11717023E
Built
2009 (earliest permit on file)
Jurisdiction
Tucson
Zoning
OCR-2
Assessor use
Gas-Electric Transmission Operating Prop
Parcel size
2.38 acres
Sewer
Connection on file (1945, 2011, 2016) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2025 permit was issued; completion is not confirmed in the available record; the permit description states “Install new 200A service for 9 new electric vehicle chargers”.

See the property

County aerial photograph centered on 88 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2025 permit specifies this work (the permit description states “Install new 200A service for 9 new electric vehicle chargers”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Inspections. City inspection record: COT - LCEL - Electrical Final approved 2025-10-03. TC-COM-0525-00970 — Install new 200A service for 9 new electric vehicle chargers
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Hiller to install NAPCO cellular communicator required to monitor the fire alarm system.”. Last permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0724-00525 — Add 2 and relocate two sprinkler pendents for added offices.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth confirming

    A pool or spa was permitted in 2022. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    Solar was permitted here in 2011. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Era-based check

    A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-02-11 (TF-FCP-0226-00093) — Hiller to install NAPCO cellular communicator required to monitor the fire alarm system..

Permit history (76)

Permit history for this parcel — 8 of 76 records
DateRecordWhatStatusValue
2026-02-11expires 2026-09-27TF-FCP-0226-00093City permit recordFire ConstructionHiller to install NAPCO cellular communicator required to monitor the fire alarm system.Issued
2025-07-09finaledTR-UTL-0725-01099City permit recordRight-of-Way (ROW) - UtilityWO T152176 - TEP to install new xfmr on private property, vehicles to be parked in ROW.Complete
2025-05-12expired 2026-04-01TC-COM-0525-00970City permit recordCommercial BuildingInstall new 200A service for 9 new electric vehicle chargersInspections
2025-03-07expired 2026-06-08TC-COM-0325-00457City permit recordCommercial BuildingNEW ELECTRICAL HEATERS, GAS HEATER, AND TV MOUNTED TO EXISTING MOUNT. NO SITE WORK FOR THIS PERMIT.Inspections
2024-07-01finaledTF-FCP-0724-00525City permit recordFire ConstructionAdd 2 and relocate two sprinkler pendents for added offices.Complete
2024-06-25TF-FCP-0624-00495City permit recordFire ConstructionVOID-Submit under Permit#TF-FCP-0624-00445 - To Install 1 new speaker / Strobe for two remodeled officesVoid
2024-06-11finaledTF-FCP-0624-00445City permit recordFire ConstructionDOUBLE EXPEDITE - to remove existing strobes and will install 2 new strobes for two remodeled restroomsComplete
2024-05-30TD-DEV-0524-00166City permit recordPool / spaMiss Saigon Downtown, seeks to enhance its outdoor dining experience by constructing pergola structures in the outdoor patio area. The placement of the peroglas will span along the North side of the patio as well as the East side of the patio. The purpose of this structure is to provide our guests a more comfortable and private dining experience. The structures will also provide shade from the sun during the early morning and earlly evening hours. The design of this structure will add to the aesthetics of the existing remodel that Miss Saigon has recently finished to the interior space. The final piece to make this space a truely unique and one of a kind establishment in downtown Tucson.Withdrawn

68 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2009-03-31T09DV01561Housing code violationENVIRONMENTALrecorded before 2023NOVERIFY

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11717023E — 76 permits on file from 2010 to 2026 (9 combo, 8 row, 7 firecons, 6 fire construction) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.