Electrical permit history — 45 N Stone Av

45 N Stone Av, Tucson — built 1975, with 86 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

45 N Stone Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1975 — 1970s commercial stock · 86 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2009 trade permit permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2009 trade permit permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onA newer 2019 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Automatic Fire Extingshing Sys - MODIFY EXISTING WET PIPE FIRE SPRINKLER SYSTEM.; Commercial Fire Sprinkler Systems - Modification of heads: 2”. Last permitted 2009 (17 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T09BU00546 — FIRE ALARM REPLACEMENT
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2020. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 39,865 sq ft (county building-footprint layer; capped at the parcel’s land area — a mapped structure crosses the lot line)
Usable for solar, planning estimate
≈ 27,900 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 310 kW — roughly 780 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 510,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$41,000–$66,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 1.5 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11712032B
Year constructed
1975 (assessor record)
Permitting authority
Tucson
Zoning
OCR-2
Property type
County Commercial Property
Building area
213,066 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2020. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2020. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 86 building permits for this parcel dated between 1997 and 2020. By category the work is addition / alteration (41), fire automatic extinguishing system (30), trade permit (11) and peddler permit (3). 69 of them carry a final inspection; the other 17 were issued, expired or are still open, which is not the same as work completed. There is 1 code-enforcement case recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11712032B. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All institutional and public property · Commercial property in 85701 · Commercial & industrial reports · Homes in 85701 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N STONE AV hold 1,157 City permits on record, 174 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (87 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2020T20CM06768Commercial Trade PermitComplete
2019T19FC00401Fire Automatic Extinguishing System PermitExpired
2017DP17-0250Development PackageSubmitted
2016T16OT01452Peddler PermitCanceled
2014T14CM05338Commercial Trade PermitCanceled
2013T13DV07455PEDDLERSNOVERIFY
2012T12OT00914Peddler PermitCanceled
2011T11OT01225Peddler PermitCanceled
2009T09OT01873Commercial Addition/Alteration PermitCanceled
2009T09BU00546Commercial Trade PermitComplete
2009T09BU00407Commercial Trade PermitComplete
2009T09BU00295Commercial Addition/Alteration PermitCanceled
2007T07BU00159Fire Automatic Extinguishing System PermitComplete
2007T06CM05897Commercial Addition/Alteration PermitComplete
2006T06CM05478Commercial Addition/Alteration PermitComplete
2005T05BU01858Fire Automatic Extinguishing System PermitComplete
2005T05CM03743Commercial Addition/Alteration PermitComplete
2004T04CM02429Commercial Addition/Alteration PermitComplete
2004T04BU01999Fire Automatic Extinguishing System PermitComplete
2004T04CM03101Commercial Addition/Alteration PermitComplete
2004T04BU01647Fire Automatic Extinguishing System PermitComplete
2004T04BU01437Fire Automatic Extinguishing System PermitComplete
2004T04CM02693Commercial Addition/Alteration PermitComplete
2004T04CM02696Commercial Addition/Alteration PermitComplete
2004T04CM02023Commercial Addition/Alteration PermitComplete
2004T04CM01175Commercial Addition/Alteration PermitComplete
2004T04CM01201Commercial Addition/Alteration PermitComplete
2002T02BU03077Fire Automatic Extinguishing System PermitComplete
2002T02CM05476Commercial Addition/Alteration PermitComplete
2002T02BU02943Fire Automatic Extinguishing System PermitComplete
2002T02CM04818Commercial Addition/Alteration PermitComplete
2001T01CM05559Commercial Addition/Alteration PermitComplete
2001T01EL02767Commercial Trade PermitComplete
2001T01BU02720Fire Automatic Extinguishing System PermitCanceled
2001T01BU02721Fire Automatic Extinguishing System PermitCanceled
2001T01CM04141Commercial Addition/Alteration PermitComplete
2001T01CM03854Commercial Addition/Alteration PermitComplete
2001T01BU01755Fire Automatic Extinguishing System PermitComplete
2001T01CM02126Commercial Addition/Alteration PermitComplete
2001T01BU00987Fire Automatic Extinguishing System PermitComplete
2001T01CM01493Commercial Addition/Alteration PermitComplete
2001T01BU00684Fire Automatic Extinguishing System PermitComplete
2001T01CM00575Commercial Addition/Alteration PermitWithdrawn
2001T00CM05127Commercial Addition/Alteration PermitComplete
2001T01BU00196Fire Automatic Extinguishing System PermitComplete
2001T01BU00183Fire Automatic Extinguishing System PermitComplete
2001T01CM00230Commercial Addition/Alteration PermitComplete
2001T00CM06067Commercial Addition/Alteration PermitComplete
2001T01CM00051Commercial Addition/Alteration PermitComplete
2000T00ME01176Commercial Trade PermitComplete
2000T00PL01744Commercial Trade PermitCanceled
2000T00BU01931Fire Automatic Extinguishing System PermitComplete
2000T00BU00783Fire Automatic Extinguishing System PermitComplete
2000T00CM00962Commercial Addition/Alteration PermitComplete
2000T00BU00450Fire Automatic Extinguishing System PermitComplete
1999T99CM05998Commercial Addition/Alteration PermitComplete
1999T99CM05956Commercial Addition/Alteration PermitComplete
1999T99BU03398Fire Automatic Extinguishing System PermitComplete
1999T99BU03358Fire Automatic Extinguishing System PermitComplete
1999T99BU03359Fire Automatic Extinguishing System PermitComplete
1999T99CM05652Commercial Addition/Alteration PermitComplete
1999T99CM05653Commercial Addition/Alteration PermitComplete
1999T99EL01624Commercial Trade PermitCanceled
1999T99BU01660Fire Automatic Extinguishing System PermitComplete
1999T99CM02461Commercial Addition/Alteration PermitComplete
1998T98BU02417Fire Automatic Extinguishing System PermitComplete
1998T98BU02261Fire Automatic Extinguishing System PermitComplete
1998T98CM03727Commercial Addition/Alteration PermitComplete
1998T98CM03629Commercial Addition/Alteration PermitComplete
1998T98BU02025Fire Automatic Extinguishing System PermitComplete
1998T98BU02026Fire Automatic Extinguishing System PermitComplete
1998T98CM03275Commercial Addition/Alteration PermitComplete
1998T98BU01759Fire Automatic Extinguishing System PermitComplete
1998T98BU01760Fire Automatic Extinguishing System PermitComplete
1998T98BU01677Fire Automatic Extinguishing System PermitComplete
1998T98CM02564Commercial Addition/Alteration PermitCanceled
1998T98CM02565Commercial Addition/Alteration PermitComplete
1998T98CM02454Commercial Addition/Alteration PermitComplete
1998T98CM02455Commercial Addition/Alteration PermitCanceled
1998T98CM02319Commercial Addition/Alteration PermitCanceled
1998T98BU00739Commercial Addition/Alteration PermitComplete
1998T98CM00973Commercial Addition/Alteration PermitComplete
1998T98CM00057Commercial Addition/Alteration PermitComplete
1997T97BU01857Commercial Trade PermitComplete
1997T97PL00502Commercial Trade PermitComplete
1997T97BU00600Fire Automatic Extinguishing System PermitComplete
1997T97BU00411Commercial Trade PermitCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11712032B — 86 City permits on file from 1997 to 2020 and 1 code enforcement case — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.