Electrical permit history — 110 E Pennington St

110 E Pennington St, Tucson — built 2005, with 40 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

110 E Pennington St

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 2005 — 2000s commercial stock · HVAC 2007 (finaled)

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 special events fire permit - organizer permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service work shows in the record we read — unremarkable for a building of this age, whose service was sized to modern code at construction. The live question is spare capacity for new loads (EV charging, kitchen or process equipment), not the age of the gear. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalLikely dueLast permitted 2007 (19 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T07CM00193 — RELOCATE:HVAC UNITS
  • Fire alarm & life safetyFinaled permit foundA newer 2021 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Automatic Fire Extingshing Sys - Re-Pipe Existing Fire Suppression System.; Commercial Cooking Suppression - New System: 1”. Last permitted 2012 (14 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T12BU00998 — Add 4 fire sprinklers
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2012. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 1.4 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11712001A
Year constructed
2005 (assessor record)
Permitting authority
Tucson
Zoning
OCR-2
Property type
Municipal Commercial Property
Building area
240,047 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 40 building permits for this parcel dated between 1997 and 2026. By category the work is fire automatic extinguishing system (10), addition / alteration (6), trade permit (5) and permanent sign (3). 27 of them carry a final inspection; the other 13 were issued, expired or are still open, which is not the same as work completed. There are 2 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11712001A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All institutional and public property · Commercial property in 85701 · Commercial & industrial reports · Homes in 85701 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E PENNINGTON ST hold 201 City permits on record, 51 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (42 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026recordRight-of-Way (ROW) Permit - GeneralIssued
2025recordROW Permit - Special EventsComplete
2025recordROW Permit - General Emergency UseComplete
2024TC-COM-0723-01639Commercial Addition/Alteration PermitIssued
2024TD-DEV-0723-00320Development PackageIssued
2023SD-0723-00080Rio Nuevo Area (RNA)Fees Paid
2021T21OT00782Permanent Sign PermitComplete
2021T21FC00800Fire Automatic Extinguishing System PermitExpired
2019T19FO00252Special Events Fire Permit - OrganizerComplete
2019T19FC00106Fire Alarm System PermitExpired
2018T18DV07583EMERGENCYCOMPLIAN
2018T18DV01912SIGN VIOLATIONCOMPLIAN
2018recordRight-of-Way (ROW) Permit - GeneralComplete
2014T14OT00811Peddler PermitCanceled
2013T13OT01424Permanent Sign PermitCanceled
2012T12BU00998Fire Automatic Extinguishing System PermitComplete
2012T12CM04408Commercial Addition/Alteration PermitComplete
2012T12SA00240Zoning ComplianceApproved
2012T12CM03455Commercial Addition/Alteration PermitComplete
2012T12CM00904Commercial Trade PermitComplete
2007T07CM00193Commercial Trade PermitComplete
2006T06BU00113Commercial Trade PermitComplete
2005T05OT02956Permanent Sign PermitComplete
2005T05BU02439Fire Automatic Extinguishing System PermitComplete
2005T05CM03729Commercial Addition/Alteration PermitComplete
2005T05BU02008Fire Automatic Extinguishing System PermitComplete
2005T05SA00262Zoning ComplianceApproved
2005T05BU00957Fire Automatic Extinguishing System PermitComplete
2005T05CM00955Commercial Addition/Alteration PermitComplete
2005T05BU00123Fire Automatic Extinguishing System PermitComplete
2005T04CM04885Commercial New Building PermitComplete
2004T04CM03776Commercial New Building PermitComplete
2004T04CM03672Commercial New Building PermitComplete
2004T04BU02651GradingCanceled
2003T03BU03062Commercial DemolitionCanceled
2000T00ME00003Commercial Trade PermitComplete
1999T99BU00425Fire Automatic Extinguishing System PermitComplete
1999T99ME00229Commercial Trade PermitComplete
1998T98BU03083Fire Automatic Extinguishing System PermitComplete
1997T97BU01113Fire Automatic Extinguishing System PermitComplete
1997T97CM00175Commercial Addition/Alteration PermitCanceled
1997T97BU00351Fire Automatic Extinguishing System PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11712001A — 40 City permits on file from 1997 to 2026 and 2 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.