Electrical permit history — 101 E Pennington St

101 E Pennington St, Tucson — built 1919, with 30 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

101 E Pennington St

Built 1919 — 1910s commercial stock · 30 permits on record; no permitted panel/service or HVAC work among them

Parcel
11711102A
Built
1919 (assessor record)
Jurisdiction
Tucson
Zoning
OCR-2
Assessor use
Restaurant Sit Down W/ Cocktail Lounge
Parcel size
0.15 acres
Building area
7,543 sq ft (assessor record)
Sewer
Connection on file (2012, 2014, 2017) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Downtown Tucson Historic District — National Register district — Contributing (City of Tucson)

See the property

County aerial photograph centered on 101 E Pennington St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0323-00472 — add 2 fire sprinklers to existing
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Most recent permit on record for this parcel: 2023-06-14 (TF-FCP-0623-00757) — VOID-Submit under Permit#TF-FCP-0323-00472-fire sprinkler add to building addition change.

Permit history (30)

Permit history for this parcel — 8 of 30 records
DateRecordWhatStatusValue
2023-06-14TF-FCP-0623-00757City permit recordAddition / alterationVOID-Submit under Permit#TF-FCP-0323-00472-fire sprinkler add to building addition changeVoid
2023-05-11TF-FCP-0523-00686City permit recordAddition / alterationVOID-PLEASE SUBMIT UNDER PERMIT#TF-FCP-0323-00472-fire sprinkler add to building addition change in work for permit TF-FCP-0323-00472Void
2023-03-13finaledTF-FCP-0323-00472City permit recordFire Constructionadd 2 fire sprinklers to existingComplete
2022-06-28finaledT22RW02338City permit recordROWWO# PRJ226823-1 Cox to Pull Approx 189' of new fiber through existing conduit for system tie. 99 E Pennington St is th physical address but do the fact that this address is not recognized in Permits Plus 101 E Pennington St is the alternate address. THIS PROJECT IS LOCATED IN AN ARCHAEOLOGICAL SENSITIVITY ZONE. AN ARCHAEOLOGICAL MONITOR HIRED BY THE PERMIT APPLICANT IS REQUIRED TO BE ON-SITE DURING ANY DIGGING, UNLESS A WAIVER IS ISSUED. MONITORING REPORTS ARE TO BE SUBMITTED TO HISTORIC PRESERVATION OFFICE, CITY OF TUCSON, P.O. BOX 27210, TUCSON, AZ 85726.** PLEASE CONTACT JODIE BROWN AT JODIE.BROWN@TUCSONAZ.GOV WITH ANY QUESTIONS. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.Final
2022-01-20completed 2022-10-28T22SA00024Design reviewRio Nuevo Area (RNA)REILLY BEER GARDEN UPPER DECKApproved
2021-11-29expired 2022-09-12DP21-0321City permit recordDevelopment PackageSite: Reilly Craft Pizza and Drink Beer Garden. New upper deck patio on existing building.Issued
2021-10-21expired 2024-01-23T21CM08315City permit recordCommercial BuildingNew upper Deck PatioIssued
2020-02-27finaledT20RW01237City permit recordROWN.677767 - JOB WILL REQUIRE ACCESS TO MH #2A-86 TO SPLICE FIBER ADDRESS ON APPLICATION IS 99 E PENNINGTON STFinal
Show 22 older records
Permit history for this parcel — remaining 22 records
DateRecordWhatStatusValue
2019-08-26expired 2020-09-05T19FC00678City permit recordFIRECONSRE-PIPE EXISTING FIRE SYSTEMWithdrwn
2019-03-21finaledT19RW01506City permit recordROWCENTURYLINK TO ACCESS MH #86 AND MH #2A D TO SPLICE FIBERSFinal
2018-08-31finaledT18RW03911City permit recordROWACCESS MANHOLE #86 TO SPLICE EXISTING FIBERSFinal
2014-12-02finaledT14BU01337City permit recordSPKLRFIRE SPRKFinal
2014-11-12finaledT14BU01247City permit recordBUILDFIRE ALARMFinal
2014-06-02finaledT14CM03304City permit recordCOMBOTOUGH LUCK BARFinal
2013-07-23finaledT13BU00862City permit recordBUILDFIRE ALARMFinal
2013-07-18finaledT13CM04363City permit recordAddition / alterationPATIO AND HISTORIC FACADE ALTERATIONSFinal
2013-04-09finaledT13BU00425City permit recordSPKLRFIRE SPRINKLERSFinal
2012-10-30finaledDP12-0197City permit recordDevelopment PackageSITE FOR ADDING BEER GARDEN TO RESTAURANTComplete
2012-07-12finaledT12BU00853City permit recordBUILDKITCHEN EXHAUST HOOD FIRE SUPPRESSIONFinal
2012-06-29finaledT12CM03884City permit recordCOMBORESIDENTIAL OR BUSINESSC of o
2012-06-29finaledT12CM03882City permit recordCOMBORESIDENTIAL OR COMMERCIALC of o
2012-06-20expired 2023-04-03T12BU00784City permit recordSPKLRInstall 52' of 2 1/2" undergroundClosed
2012-06-13finaledT12CM03444City permit recordCOMBOBEER GARDENC of o
2012-05-22finaledT12BU00647City permit recordBUILDFIRE ALARMFinal
2012-05-21finaledT12OT00783City permit recordFence / wallREPAIR PERMIT FOR EXSITING PROJECTING WALL SIGN PER GLENN MOYERFinal
2012-05-10expired 2012-09-07T12EX00224City permit recordEXCAVTRENCH/REPAIR 24LF CURB CUT, PAVEMENT CUT FOR PRIVATE SEWER, 250 LF TEP, AND 6LF GASClosed
2012-04-27expired 2012-06-26T12EX00179City permit recordEXCAVTRENCH 30' OF PAVEMENT AND 5' OF SIDEWALK ON SCOTT AVE TO INSTALL 4" FIRE SERVICE (APA)Closed
2012-03-26finaledT12BU00395City permit recordSPKLRInstall 15' of 4" underground & 122 fire sprinklersFinal
2011-12-07finaledT11CM03738City permit recordCOMBORESTAURANTC of o
2011-11-18finaledT11CM03570City permit recordCOMBOTI; INTERIOR DEMOFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2015-10-09T15DV07730Code enforcement caseCode enforcement caseReferred
2013-02-28T13DV01183Code enforcement caseWork without permitNoverify

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11711102A — 30 permits on file from 2011 to 2023 (6 combo, 4 row, 4 spklr, 4 build) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.