Electrical permit history — 250 S Toole Av

250 S Toole Av, Tucson — built 1999, with 43 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

250 S Toole Av

Built 1999 — 1990s commercial stock · 43 permits on record; no permitted panel/service or HVAC work among them

Parcel
11706318B
Built
1999 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Medical Services No Lab Or X-Ray
Parcel size
2.84 acres
Building area
38,652 sq ft (assessor record)
Sewer
Connection on file (2000, 2002, 2017) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 250 S Toole Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22FC00395 — Fire Alarm & Detection Systems - To install 1ea. Telguard TG7 Cellular radio and take over 24 hour larm monitoring on existing Siemens Cerebus Alarm Panel.; Fire Alarm Systems - Monitor Only
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Most recent permit on record for this parcel: 2026-01-26 (TF-FOP-0126-00126) — annual inspection.

Permit history (43)

Permit history for this parcel — 8 of 43 records
DateRecordWhatStatusValue
2026-01-26finaledTF-FOP-0126-00126City permit recordFire Operationalannual inspectionComplete
2025-01-27finaledTF-FOP-0125-00121City permit recordFire OperationalAnnual Fire InspectionComplete
2024-01-02finaledTF-FOP-0124-00003City permit recordFire OperationalAnnual inspectionComplete
2023-01-27TF-FOP-0123-00417City permit recordFire OperationalVOID-RESUBMITTED PERMIT#TF-FOP-0123-00419-Behavioral Health Facility (84 beds)Void
2023-01-27finaledTF-FOP-0123-00419City permit recordFire OperationalCBI Behavioral Health (84 Beds)Complete
2023-01-10TF-FOP-0123-00327City permit recordFire OperationalVOID-PLEASE SUBMIT A FIRE STATE LICENSED FACILITY PERMIT - Annual inspection with PiotrowskiVoid
2022-06-08finaledT22FC00395City permit recordFire ConstructionFire Alarm & Detection Systems - To install 1ea. Telguard TG7 Cellular radio and take over 24 hour larm monitoring on existing Siemens Cerebus Alarm Panel.; Fire Alarm Systems - Monitor OnlyComplete
2022-03-23finaledT22RW01121City permit recordROWWO# 210769 Replace hydrant on north side of address in dirt easement and sidewalk area on 12th Street@4LF. THIS PROJECT IS LOCATED IN AN ARCHAEOLOGICAL SENSITIVITY ZONE. AN ARCHAEOLOGICAL MONITOR HIRED BY THE PERMIT APPLICANT IS REQUIRED TO BE ON-SITE DURING ANY DIGGING, UNLESS A WAIVER IS ISSUED. MONITORING REPORTS ARE TO BE SUBMITTED TO HISTORIC PRESERVATION OFFICE, CITY OF TUCSON, P.O. BOX 27210, TUCSON, AZ 85726.** PLEASE CONTACT JODIE BROWN AT JODIE.BROWN@TUCSONAZ.GOV WITH ANY QUESTIONS ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUALFinal
Show 35 older records
Permit history for this parcel — remaining 35 records
DateRecordWhatStatusValue
2021-12-22finaledT21FO00894City permit recordFIREOPER84 BEDSFinal
2021-01-06finaledT21FO00012City permit recordFIREOPERCommunity Bridges - 40 BEDSFinal
2019-07-17finaledT19RW03995City permit recordROWREMOVAL AND REPLACEMENT OF RAMPS AND SIDEWALK TO MAKE THEM ADA COMPLIANT ADDRESS ON APPLICATION-TOOLE AV AND 7TH AV-NE CORNER OF SOUTHSIDE OF TOOLE CIP JOB # 171729Final
2018-08-03finaledT18OT00830City permit recordC-OF-OMEDICAL OFFICEC of o
2018-05-14finaledT18OT00506City permit recordC-OF-OMEDICAL OFFICEC of o
2018-05-14finaledT18OT00507City permit recordC-OF-OC OF O MEDICAL OFFICEC of o
2018-02-05expired 2019-02-27T18FC00121City permit recordAddition / alterationFire Alarm & Detection Systems - 2ND HALF TI, EXISTING PANEL MODIFICATION; Fire Alarm Systems - New Sq Ft: 16964; Fire Alarm Systems - # New Stories: 1; Additional Inspections: 3Expired
2017-08-30finaledT17FC00721City permit recordFIRECONSMODIFY THE EXISTING SPRINKLER SYSTEM TO NEW FLOOR PLANFinal
2017-05-30finaledT17CM04232City permit recordCOMBOTI; MEDICAL OFFICEL of c
2017-02-15expired 2017-09-03T17CM01250City permit recordCOMBOINTERIOR DEMOExpired
2016-12-19expired 2017-06-17T16OT01498City permit recordFence / wall1-ILLUM WALL SIGNExpired
2016-12-05finaledT16FC00292City permit recordFIRECONSInstall a new Fire Suppression systemFinal
2016-09-22finaledT16RW01630City permit recordROWDIRECTIONAL BORE IN COT RIGHT OF WAY; POTHOLING FOR EXISTING UG UTILITIES UNDER ASPHALT IN ROADWAY WILL ALSO BE REQUIRED AS WELL AS BORE PITS WORK ORDER # N.103560Final
2016-08-09expired 2017-05-31T16CM06236City permit recordCOMBO3 NEW LIGHT POLES IN PARKING LOT; COMMExpired
2016-06-21finaledT16BU00945City permit recordBUILDFIRE ALARMFinal
2016-06-14finaledT16BU00893City permit recordSPKLRFIRE SPRKLFinal
2016-05-03finaledT16CM03212City permit recordCOMBOTI: INTERIOR REMODELC of o
2009-05-08expired 2009-11-30T09CM01164City permit recordCOMBOTI: STORAGEExpired
2005-04-04finaledT05OT00787City permit recordSIGNSIGN:#8774 D E S #222-01Final
2004-08-04finaledT04BU01926City permit recordSPKLRFIRE SPKR:ADD 1Final
2004-06-01finaledT04CM02455City permit recordCOMBOTI:WAREHOUSEC of o
2002-03-19T02AN00241City permit recordADDRNEWIssued
2002-02-20finaledT02BU00542City permit recordSPKLRFIRE SPKR:RELOCATE 18 & ADD 13Final
2001-12-21finaledT01CM06176City permit recordCOMBOTI:TRAINING ROOMC of o
2001-10-16expired 2001-12-15T01EX01197City permit recordEXCAVEXCAV:INSTALL SIDEWALKSClosed
2000-06-14expired 2000-08-13T00EX00835City permit recordEXCAVEXCAV:350 LF OF SIDEWALKClosed
1999-05-10finaledT99BU01264City permit recordSPKLRFIRE SPKR:295 NEWFinal
1999-04-21P99AN01080City permit recordADDRNEWIssued
1999-04-06finaledT99CM01541City permit recordCOMBOTI:OFFICEC of o
1999-03-29finaledT99BU00809City permit recordSPKLRFIRE SPKR:UNDERGRND PIPINGFinal
1999-03-22finaledT99CM01249City permit recordCOMBOOFFICE & WAREHOUSE:SHELL ONLYFinal
1999-03-09finaledT99BU00616City permit recordFence / wallWALL:RETAINING 300LF OF 3WITH 4 ON TOPFinal
1999-03-08finaledT99BU00606City permit recordFence / wallWALL:DEMO 5WALLFinal
1999-03-08finaledT99PL00483City permit recordPLUMBSEWER:HCSFinal
1998-03-13D98-0023City permit recordDevelopment PackageCUSHING BUSINESS CENTER PHASE IVApproved

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (9)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 9 records
DateRecordWhatStatus
2025-12-11CE-VIO1225-05337Code enforcement caseCode enforcement caseClosed - unfounded
2024-05-31CE-VIO0524-02109Code enforcement caseVegetationClosed - unfounded
2023-08-04CE-VIO0823-04968Code enforcement caseVegetationClosed - resolved
2021-06-02T21DV03314Code enforcement caseRefuseComplian
2020-04-07T20DV02287Code enforcement caseRefuseNoverify
2013-04-09finaledT13DV02261Code enforcement caseCode enforcement caseComplete
2009-10-21T09DV06019Code enforcement caseVegetationComplian
2008-09-25T08FR03092Code enforcement caseCode enforcement caseField
Show 1 older record
Code enforcement history for this parcel — remaining 1 records
DateRecordWhatStatus
2007-04-10T07DV03224Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11706318B — 43 permits on file from 1998 to 2026 (9 combo, 6 fire operational, 5 spklr, 3 row) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.