Electrical permit history — 402 E 9th St
402 E 9th St, Tucson — built 1958, with 31 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
402 E 9th St
Built 1958 — 1950s multifamily stock · 31 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 402 E 9th St (aztucsonelectricalsolutions.com/property/11706297a/402-e-9th-st-tucson-az-85705) · Public records last checked 2026-08-17
- Parcel
- 11706297A
- Built
- 1958 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-3
- Assessor use
- Apartments 25 - 99 Units 3 Or More Story
- Parcel size
- 0.20 acres
- Building area
- 15,768 sq ft (assessor record)
- Sewer
- Connection on file (2013, 2017) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Iron Horse Expansion Historic District — National Register district — Contributing (City of Tucson)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 combo permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 combo permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2017 (9 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T17FC00129 — Add 3, relocate 56 fire sprinklers
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2017. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Recorded sales (3)
| Date | Price | Type |
|---|---|---|
| 2021-02-26 | $3,600,000 | Warranty Deed |
| 2015-05-28 | $1,400,000 | Warranty Deed |
| 2010-02-10 | $760,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-06-25 (TZ-PMT-0626-00055) — REGULATED PEDDLER: Only Wings LLC / Cheyenne Corral / PC Health Dept Lic # 24-210169 Exp 12/31/26.
Permit history (31)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-25finaled | TZ-PMT-0626-00055City permit record | Zoning Permit AnnualREGULATED PEDDLER: Only Wings LLC / Cheyenne Corral / PC Health Dept Lic # 24-210169 Exp 12/31/26 | Complete | |
| 2025-04-29finaled | TZ-PMT-0425-00041City permit record | Zoning Permit AnnualOnlyWings, LLC applying for Peddlers License so that my food trailer can be parked at Traxide Taproom for business. | Complete | |
| 2025-04-15 | TZ-PMT-0425-00035City permit record | Zoning Permit AnnualApplication for Peddler Permit to conduct a peddler operation (OnlyWings, LLC) on property consistent with regulations under Tucson Code Sections 7-26 thru 37. | Expired | |
| 2024-04-23finaled | TR-UTL-0424-00854City permit record | Right-of-Way (ROW) - UtilityAccess to manhole for State Attorney General Audit | Complete | |
| 2024-03-27 | TR-UTL-0324-00641City permit record | Right-of-Way (ROW) - UtilityNeed Access to MH #16 for State Attorney General Audit - 129 feet south of building. No Traffic Control Plan needed. | Needs resubmittal | |
| 2021-05-17finaled | T21FO00294City permit record | FIREOPERDILLINGER BREWING COMPANY - OCC 57 | Final | |
| 2021-02-04finaled | T21CM01055City permit record | COMBOTenant improvement | Final | |
| 2021-01-13 | DP21-0012City permit record | Development PackageSITE - Dillinger Brewing Company. | Approved |
Show 23 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2018-08-02finaled | T18RW03453City permit record | ROWINSTALLATION OF TWO SPEED TABLES | Final | |
| 2017-06-07expired 2017-09-15 | T17RW02448City permit record | ROWCLOSURE OF SIDEWALK AT 9TH ST & PEDESTRAIN UNDERPASS AT 4TH AV FOR POSITIONING OF AN APPROX. 5' X 8' LIFT FOR PAINTING | Expired | |
| 2017-05-02finaled | T17RW01869City permit record | Pool / spaDUMPSTER TO BE PLACED IN PARKING SPACE FOR DIRT/CONCRETE REMOVAL | Final | |
| 2017-02-09finaled | T17FC00129City permit record | FIRECONSAdd 3, relocate 56 fire sprinklers | Final | |
| 2017-01-19finaled | T17FC00054City permit record | FIRECONSfire alarm systems | Final | |
| 2016-12-06finaled | T16FO00136City permit record | FIREOPERTent over patio of Restaurant Set- up Dec 8th Tear-down January 03 | Final | |
| 2016-08-17finaled | T16CM06402City permit record | COMBOTI: APARTMENTS | L of c | |
| 2016-04-14expired 2016-10-16 | T16CM02726City permit record | COMBOINTERIOR DEMO | Expired | |
| 2014-12-04expired 2015-02-02 | T14EX01233City permit record | EXCAVEXCAVATION,BACKFILL AND ALL SURFACE REPAIRS SHALL BE PER COT STANDARD DETAILS AND STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. EXPANDING SIDEWALK BY 4TH AVE UNDERPASS.CONTACT PARK TUCSON AT 520-791-5071; AREA IS IN PERMIT PARKING. *WORK OF 11/05/2015 | Closed | |
| 2014-11-05expired 2015-01-04 | T14EX01165City permit record | EXCAVEXPANDING SIDEWALK BY 4TH AVE UNDERPASS | Closed | |
| 2013-10-18finaled | T13OT01233City permit record | SIGNINSTALL (3) NON ILLUMINATED AWNING SIGNS AND AWNINGS. TRE 2013-030 ISSUED | Final | |
| 2013-09-09finaled | T13BU01024City permit record | SPKLRSPRINKLERS-RELOCATE 2 HEADS | Final | |
| 2013-07-12finaled | T13EX00893City permit record | EXCAVREMOVE STONE PATIO PLANTERS SURROUNDING TREES ON SIDEWALK NORTH OF BULD. REPLACE WITH IRON TREE GRATES. NORTHERN TREE IS TO BE LOCATED | Final | |
| 2013-06-06finaled | T13OT00672City permit record | SIGNPERMIT T13OT00672. HISTORIC LANDMARK SIGN CASE T13SA00109 - 2 PROJECTING SIGN CABINETS = 1 HLS W/CONDITIONS REPAIR NEON & CABINETS (30.6 & 5.12 SQFT) RELOCATE SMALL CABINET ON SITE TO MOUNT UNDER LARGE CABINET@NW CORNER OF BLDG, ADAPTIVE REUSE ON SMALL CABINET ONLY TRE 2013-030 A&B FOR SIGNS IN RIGHT OF WAY. **** REVISION APPROVED AS MINOR REVIEW 12/2/13 UNDER SEPARATE CASE HPZ13-50/T13SA00330 FOR: TOP CABINET ALL AQUA NEON NOW, BOTTOM CABINET WHITE NEON, CHANGE WHITE NEON FONT AND ADD WHITE PAINTED LETTERS AGOVE WHITE NEON. **** | Final | |
| 2013-05-23finaled | T13CM03138City permit record | COMBORESTAURANT | C of o | |
| 2013-05-06finaled | DP13-0076City permit record | Development PackageSITE | Complete | |
| 2013-05-06 | T13CM02720City permit record | COMBOPATIO | Withdrwn | |
| 2012-08-28expired 2013-08-28 | T12OT01276City permit record | PEDDLERconnie & rene's hot dogs regulated peddler | Expired | |
| 2012-08-01expired 2013-08-01 | T12OT01146City permit record | PEDDLERzeppelin hot dogs regulated peddler | Expired | |
| 2011-09-08expired 2012-09-07 | T11OT01760City permit record | PEDDLERPEDDLER: CONNIE & RENE SONORA STYLE HOT DOGS / CONNIE & RENE VIZCAINO. EXTENDED HOURS TO 3 A.M. = STICKER NO. 0217 ISSUED 09/08/2011 | Expired | |
| 2010-12-23expired 2011-12-23 | T10OT02718City permit record | PEDDLERRegulated Peddler/Sale of Jewelry-Necklaces, bracelets etc | Expired | |
| 2010-09-22expired 2011-09-21 | T10OT02050City permit record | PEDDLERCONNIE AND RENE SONORA STYLE HOTDOGS | Expired | |
| 1999-09-21finaled | T99CM04517City permit record | COMBOTI:APARTMENTS | C of o |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (21)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2026-04-27 | CE-VIO0426-01850Code enforcement case | Code enforcement case | Closed - unfounded |
| 2026-04-24 | CE-VIO0426-01804Code enforcement case | Fire | Closed - resolved |
| 2025-05-05 | CE-VIO0525-01888Code enforcement case | Code enforcement case | Closed - unfounded |
| 2022-06-15 | T22DV03413Code enforcement case | Code enforcement case | Closed - resolved |
| 2021-09-08 | T21DV06201Code enforcement case | Code enforcement case | Complian |
| 2021-06-22 | T21DV03946Code enforcement case | Code enforcement case | Noverify |
| 2020-10-21 | T20DV06970Housing code violation | WORK WITHOUT PERMITS-COMMERCLrecorded before 2023 | COMPLIAN |
| 2016-01-07 | T16DV00068Code enforcement case | Code enforcement case | Complian |
Show 13 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2015-10-03 | T15DV07425Code enforcement case | Code enforcement case | Referred |
| 2013-06-28 | T13DV04509Code enforcement case | Refuse | Noverify |
| 2013-02-28 | T13DV01184Code enforcement case | Code enforcement case | Noverify |
| 2011-09-07 | T11DV07133Code enforcement case | Fire | Noverify |
| 2007-07-17finaled | T07FR01331Code enforcement case | Code enforcement case | Complete |
| 2007-04-23 | T07FR00770Code enforcement case | Code enforcement case | Field |
| 2005-10-10finaled | T05FR01585Code enforcement case | Code enforcement case | Complete |
| 2005-09-20 | T05FR01464Code enforcement case | Fire | Invalid |
| 2004-07-09 | T04DV00566Code enforcement case | Code enforcement case | Referred |
| 2001-03-10 | T01VL00697Code enforcement case | Code enforcement case | Complian |
| 2001-03-10 | T01VL00698Code enforcement case | Code enforcement case | Closed |
| 2001-03-10 | T01VL00699Code enforcement case | Code enforcement case | Complian |
| 2001-03-10 | T01VL00700Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 11706297A — 31 permits on file from 1999 to 2026 (6 combo, 5 peddler, 3 zoning permit annual, 3 excav) and 21 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.