Electrical permit history — 282 E Congress St

282 E Congress St, Tucson — built 1928, with 135 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

282 E Congress St

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1928 — 1920s commercial stock · last permitted panel/service work 2010 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2010 (16 years ago). The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T10EL00917 — UPGRADE ELECTRIC FROM 60AMP TO SINGLE PHASE 400AMP
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire alarm system permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0125-00082 — EXPEDITE - ADDITION TO EXISTING FIRE SYSTEM NAC CIRCUIT (2- P2RLED HORN/STROBES)
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2010 panel/service permit is on record for this parcel, which makes it unlikely the original 30–60 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2006. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2021. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 14,274 sq ft (county building-footprint layer; capped at the parcel’s land area — a mapped structure crosses the lot line)
Usable for solar, planning estimate
≈ 10,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 110 kW — roughly 280 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 180,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$14,000–$23,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 1.3 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11706187E
Year constructed
1928 (assessor record)
Permitting authority
Tucson
Zoning
OCR-2
Property type
Retail Strip Center
Building area
14,005 sq ft
Service on record
City records show the 2010 permit was finalized; the permit description states “UPGRADE ELECTRIC FROM 60AMP TO SINGLE PHASE 400AMP” — an increase in capacity as described, not a confirmed installed rating.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 135 building permits for this parcel dated between 1998 and 2026. By category the work is addition / alteration (36), trade permit (23), zoning compliance (23) and fire automatic extinguishing system (19). 86 of them carry a final inspection; the other 49 were issued, expired or are still open, which is not the same as work completed. There are 6 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11706187E. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85701 · Commercial & industrial reports · Homes in 85701 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E CONGRESS ST hold 1,004 City permits on record, 216 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (141 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0526-02280Code enforcement caseClosed - Unfounded
2026recordRight-of-Way (ROW) Permit - UtilityInspections
2025TC-CFO-0325-00037Temporary Certificate-of-Occupancy (TCO)Withdrawn
2025TF-FCP-0125-00082Fire Alarm System PermitComplete
2025TC-CFO-0225-00025Temporary Certificate-of-Occupancy (TCO)Complete
2024TF-FCP-0924-00827Fire Automatic Extinguishing System PermitComplete
2024TC-COM-0624-01169Commercial Addition/Alteration PermitComplete
2024TS-PRM-0424-00145Permanent Sign PermitIssued
2024SD-0424-00039Historic Preservation Zone/Historic LandmarkComplete
2023TC-CFO-1123-00228Temporary Certificate-of-Occupancy (TCO)Issued
2023TS-PRM-0823-00437Permanent Sign PermitComplete
2023SD-0823-00092Historic Preservation Zone/Historic LandmarkComplete
2023TF-FCP-0723-00893Fire Automatic Extinguishing System PermitComplete
2023TC-COM-0323-00775Commercial Addition/Alteration PermitComplete
2023TC-BCA-0323-00004Building Code AppealComplete
2022T22FC00710Fire Automatic Extinguishing System PermitComplete
2022T22CM05826Commercial Addition/Alteration PermitComplete
2022T22FC00402Fire Automatic Extinguishing System PermitComplete
2021T21CM09428Commercial Trade PermitExpired
2021T21CM05852Commercial Trade PermitComplete
2020T20FC00074Fire Alarm System PermitExpired
2020T20FC00027Fire Automatic Extinguishing System PermitComplete
2019T19CM08099Commercial Trade PermitComplete
2019T19CM08268Commercial Addition/Alteration PermitExpired
2018T18FC00441Fire Alarm System PermitExpired
2018T18FO00062Special Events Fire Permit - OrganizerComplete
2018T18FC00014Fire Alarm System PermitComplete
2017T17FC00910Fire Automatic Extinguishing System PermitComplete
2017T17FC00841Fire Alarm System PermitExpired
2017T17FC00872Fire Automatic Extinguishing System PermitComplete
2017T17FC00666Fire Automatic Extinguishing System PermitComplete
2017T17CM02413Commercial Addition/Alteration PermitComplete
2017T17FC00523Fire Automatic Extinguishing System PermitExpired
2017T17FC00517Fire Alarm System PermitExpired
2017T17CM02205Commercial Addition/Alteration PermitComplete
2017T17SA00190Zoning ComplianceApproved
2017T17DV01045GRAFFITINOVERIFY
2016T16FO00172Special Events Fire Permit - VendorComplete
2016T16FO00170Special Events Fire Permit - VendorComplete
2016T16OT00265Permanent Sign PermitCanceled
2016T16BU00290Commercial Trade PermitCanceled
2016T16SA00098Zoning ComplianceComplete
2016T16BU00252Commercial Addition/Alteration PermitCanceled
2016T16BU00251Fire Automatic Extinguishing System PermitWithdrawn
2015T15BU01211Fire Automatic Extinguishing System PermitCanceled
2015T15CM05735Commercial Addition/Alteration PermitComplete
2015T15CM05056Commercial Trade PermitComplete
2015T15SA00263Zoning ComplianceComplete
2015T15CM03846Commercial Trade PermitCanceled
2015T15SA00202Zoning ComplianceComplete
2015T15DV03189GRAFFITICOMPLIAN
2015T15SA00052Zoning ComplianceComplete
2015T15CM00660Commercial Addition/Alteration PermitWithdrawn
2014T14CM08980Commercial Trade PermitComplete
2014T14CM07355Commercial Addition/Alteration PermitCanceled
2014T14SA00327Zoning ComplianceComplete
2014DP14-0039Development PackageExpired
2014T13OT01285Permanent Sign PermitCanceled
2014T14BU00206Fire Automatic Extinguishing System PermitComplete
2014T14CM00700Commercial Addition/Alteration PermitComplete
2014T14SA00001Zoning ComplianceComplete
2013T13SA00336Zoning ComplianceCanceled
2013T13OT01148Permanent Sign PermitCanceled
2013T13CM04810Commercial Addition/Alteration PermitComplete
2013T13BU00937Commercial Trade PermitCanceled
2013T13BU00965Fire Automatic Extinguishing System PermitCanceled
2013DP13-0009Development PackageComplete
2013T13BU00882Commercial Trade PermitComplete
2013T13BU00815Commercial Trade PermitCanceled
2013T13SA00186Zoning ComplianceCanceled
2013T13DV04133WORK WITHOUT PERMITS-RESIDENTLCOMPLIAN
2013T13BU00508Fire Automatic Extinguishing System PermitComplete
2013T12CM07446Commercial Addition/Alteration PermitComplete
2013DP12-0178Development PackageComplete
2013T13BU00092Fire Automatic Extinguishing System PermitComplete
2013T12CM06315Commercial Addition/Alteration PermitComplete
2012T12SA00422Zoning ComplianceComplete
2012T12SA00392Zoning ComplianceComplete
2012T12SA00388Zoning ComplianceCanceled
2012T12SA00376Zoning ComplianceCanceled
2012T12SA00342Zoning ComplianceCanceled
2012T12BU00630Commercial Trade PermitComplete
2012T12OT00559Peddler PermitCanceled
2012T12OT00327Permanent Sign PermitComplete
2012T12OT00287Permanent Sign PermitComplete
2012T12OT00328Permanent Sign PermitComplete
2012T12SA00046Zoning ComplianceCanceled
2012T12BU00051Commercial Trade PermitComplete
2011T11OT02239Permanent Sign PermitComplete
2011T11SA00464Zoning ComplianceCanceled
2011T11CM02955Commercial Addition/Alteration PermitComplete
2011T11CM02956Commercial Addition/Alteration PermitComplete
2011T11BU01438Commercial Trade PermitComplete
2011T11BU01352Fire Automatic Extinguishing System PermitComplete
2011T11SA00366Zoning ComplianceApproved
2011T11BU01167Commercial Trade PermitComplete
2011T11SA00320Zoning ComplianceCanceled
2011T11BU00206Commercial Trade PermitComplete
2011T11BU00171Commercial Trade PermitComplete
2011T11OT00173Permanent Sign PermitComplete
2011T11OT00054Permanent Sign PermitComplete
2010T10CM02964Commercial Addition/Alteration PermitComplete
2010T10BU01816Fire Automatic Extinguishing System PermitComplete
2010T10BU01798Commercial Trade PermitWithdrawn
2010T10SA00417Zoning ComplianceCanceled
2010T10SA00418Zoning ComplianceComplete
2010T10CM00463Commercial Trade PermitComplete
2010T10BU01539Fire Automatic Extinguishing System PermitComplete
2010T10CM01281Commercial Addition/Alteration PermitComplete
2010T10CM01874Commercial Addition/Alteration PermitWithdrawn
2010T10CM02459Commercial Addition/Alteration PermitComplete
2010T10CM02458Commercial Addition/Alteration PermitComplete
2010T10BU01329Fire Automatic Extinguishing System PermitComplete
2010S10-030 Land Split/Lot SplitWithdrawn
2010S10-029 Land Split/Lot SplitCanceled
2010T10CM01122Commercial Addition/Alteration PermitComplete
2010T10EL00917Commercial Trade PermitComplete
2010T10SA00120Zoning ComplianceEffectuated
2010T10CM00796Commercial Addition/Alteration PermitComplete
2010T10SA00095Zoning ComplianceApproved
2010T10SA00086Zoning ComplianceCanceled
2009T09DV03644REFUSECOMPLIAN
2009T09DV02521COMMERCIAL ZONINGNOVERIFY
2008T07CM04722Commercial Addition/Alteration PermitComplete
2007T07OT01810Commercial Addition/Alteration PermitComplete
2007T07CM01969Commercial Addition/Alteration PermitWithdrawn
2006T06EL01965Commercial Trade PermitComplete
2006T06EL01006Commercial Trade PermitComplete
2005T05EL02048Residential Trade PermitComplete
2005T05CM01915Commercial Addition/Alteration PermitComplete
2005T05OT00178Commercial Addition/Alteration PermitComplete
2004T04OT02031Permanent Sign PermitWithdrawn
2004T04EL00008Residential Trade PermitComplete
2001T01CM05116Commercial Addition/Alteration PermitComplete
2001T01OT00107Commercial Addition/Alteration PermitComplete
2001T01CM02961Commercial Addition/Alteration PermitCanceled
2001T01OT00171Commercial Addition/Alteration PermitWithdrawn
1999T99OT00097Commercial Addition/Alteration PermitComplete
1998T98OT00317Commercial Addition/Alteration PermitComplete
1998T98OT00287Commercial Addition/Alteration PermitWithdrawn
1998T98BU02740Commercial Addition/Alteration PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11706187E — 135 City permits on file from 1998 to 2026 and 6 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.