Electrical permit history — 35 S 5th Av

35 S 5th Av, Tucson — built 1922, with 102 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

35 S 5th Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1922 — 1920s commercial stock · 102 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 fire automatic extinguishing system permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 fire automatic extinguishing system permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1122-00163 — Modify existing fire sprinkler system to accomodate removed wall in kitchen, and sprinklers in non-operative hood system.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2010. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    There is an electrical reconnect permit from 2004. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2014. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 15,083 sq ft (county building-footprint layer; capped at the parcel’s land area — a mapped structure crosses the lot line)
Usable for solar, planning estimate
≈ 10,600 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 115 kW — roughly 290 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 190,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$15,000–$25,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 1.3 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11706168A
Year constructed
1922 (assessor record)
Permitting authority
Tucson
Zoning
OCR-2
Property type
Retail Strip Center
Building area
20,491 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 102 building permits for this parcel dated between 1999 and 2026. By category the work is addition / alteration (39), zoning compliance (15), trade permit (14) and permanent sign (11). 57 of them carry a final inspection; the other 45 were issued, expired or are still open, which is not the same as work completed.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11706168A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85701 · Commercial & industrial reports · Homes in 85701 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S 5TH AV hold 670 City permits on record, 199 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (102 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-COM-0226-00235Commercial Addition/Alteration PermitIssued
2026SD-0326-00053Rio Nuevo Area (RNA)Fees Paid
2026recordROW Permit - Street BannersNeeds Resubmittal
2026TC-COM-0226-00248Commercial Addition/Alteration PermitNeeds Resubmittal
2026TS-PRM-0126-00010Permanent Sign PermitInspections Complete
2026TZ-PMT-0126-00005Peddler PermitComplete
2026TC-COM-0126-00143Commercial Addition/Alteration PermitNeeds Resubmittal
2024recordRight-of-Way (ROW) Permit - GeneralComplete
2023TC-COM-1122-00122Commercial Addition/Alteration PermitIssued
2023TC-COM-0123-00561Commercial Addition/Alteration PermitIssued
2023TC-COM-0323-00799Commercial Addition/Alteration PermitIssued
2022TF-FCP-1122-00163Fire Automatic Extinguishing System PermitComplete
2022T22OT00765Permanent Sign PermitApproved
2022T22SA00477Historic Preservation Zone/Historic LandmarkApproved
2022T22FC00677Fire Alarm System PermitComplete
2022T22OT00750Permanent Sign PermitExpired
2022T22FC00445Fire Automatic Extinguishing System PermitComplete
2022T22CM04952Commercial Addition/Alteration PermitExpired
2022T22CM03260Commercial Addition/Alteration PermitComplete
2022T20CM08740Commercial Addition/Alteration PermitComplete
2021T21OT00747Permanent Sign PermitComplete
2021T21OT00299Permanent Sign PermitComplete
2021T21SA00406Zoning ComplianceComplete
2021T21CM07090Commercial Addition/Alteration PermitExpired
2021DP21-0266 Development PackageWithdrawn
2021T21SA00182Zoning ComplianceComplete
2021T21SA00082Zoning Verification LetterApproved
2021T20CM09213Commercial Addition/Alteration PermitExpired
2020T20CM06018Commercial Addition/Alteration PermitComplete
2020T17FC00112Fire Automatic Extinguishing System PermitCanceled
2020T20SA00229Zoning ComplianceApproved
2020T20CM02306Commercial Addition/Alteration PermitExpired
2017T17CM02519Commercial Addition/Alteration PermitComplete
2017T17OT00360Permanent Sign PermitComplete
2017T17SA00155Zoning ComplianceComplete
2017T17FC00212Fire Automatic Extinguishing System PermitComplete
2017T17FC00223Fire Alarm System PermitComplete
2017T16CM08849Commercial Addition/Alteration PermitComplete
2017T16CM09556Commercial Addition/Alteration PermitComplete
2016T16SA00545Zoning ComplianceApproved
2015DP14-0026Development PackageComplete
2015DP13-0002Development PackageComplete
2014T14OT00968Permanent Sign PermitCanceled
2014T14SA00268Zoning ComplianceComplete
2014T14BU00223Commercial Trade PermitComplete
2014T14BU00134Fire Automatic Extinguishing System PermitComplete
2014T13CM02975Commercial Addition/Alteration PermitComplete
2013T13SA00248Zoning ComplianceCanceled
2013T13SA00246Zoning ComplianceCanceled
2013T13SA00245Zoning ComplianceApproved
2013T13BU00536Fire Automatic Extinguishing System PermitCanceled
2013T13OT00437Permanent Sign PermitComplete
2013T13OT00410Permanent Sign PermitComplete
2013T13SA00112Zoning ComplianceCanceled
2013T13SA00111Zoning ComplianceCanceled
2013T12CM06913Commercial Addition/Alteration PermitComplete
2013T13BU00397Commercial Trade PermitComplete
2013T12CM08252Commercial Trade PermitComplete
2013T12CM08260Commercial Addition/Alteration PermitComplete
2013T12CM08253Commercial Trade PermitComplete
2013T13BU00387Commercial Trade PermitComplete
2013T13BU00311Commercial Trade PermitComplete
2013T13BU00229Fire Automatic Extinguishing System PermitComplete
2013T13BU00228Fire Automatic Extinguishing System PermitComplete
2013T13BU00292Commercial Trade PermitComplete
2013T12CM07950Commercial Addition/Alteration PermitComplete
2013T13BU00199Fire Automatic Extinguishing System PermitComplete
2013T13SA00007Zoning ComplianceApproved
2012T12SA00401Zoning ComplianceCanceled
2012T12CM06912Commercial Addition/Alteration PermitWithdrawn
2011D11-0019Development PackageApproved
2011T11OT01502Annual Portable Sign ComplianceComplete
2011T11CM00817Commercial Trade PermitWithdrawn
2010T10OT02169Permanent Sign PermitComplete
2010T10CM02714Commercial Addition/Alteration PermitComplete
2010T10OT00900Permanent Sign PermitComplete
2010T10BU00563Commercial Trade PermitComplete
2010T10CM00944Commercial Addition/Alteration PermitWithdrawn
2010T10CM00644Commercial Addition/Alteration PermitComplete
2010T10BU00464Fire Automatic Extinguishing System PermitComplete
2010T10CM00056Commercial Addition/Alteration PermitComplete
2009T09SA00268Zoning ComplianceCanceled
2009T09CM01524Commercial Addition/Alteration PermitCanceled
2009T09CM01100Commercial Addition/Alteration PermitComplete
2009T09SA00121Zoning ComplianceCanceled
2007T07CM03704Commercial Addition/Alteration PermitCanceled
2005T04CM04725Commercial Addition/Alteration PermitComplete
2005T04CM04437Commercial Addition/Alteration PermitWithdrawn
2005T05CM00260Commercial Addition/Alteration PermitWithdrawn
2004T04EL00637Commercial Trade PermitComplete
2004T04EL00638Commercial Trade PermitComplete
2004T04EL00565Commercial Trade PermitComplete
2003T03EL00292Commercial Trade PermitCanceled
2002T02OT00135Commercial Addition/Alteration PermitComplete
2002T02OT00205Commercial Addition/Alteration PermitComplete
2002T02OT00134Commercial Addition/Alteration PermitWithdrawn
2002T02EL00066Commercial Trade PermitComplete
2002T02OT00047Commercial Addition/Alteration PermitWithdrawn
2001T01OT00944Commercial Addition/Alteration PermitWithdrawn
2001T01OT00062Commercial Addition/Alteration PermitComplete
2001T01OT00043Commercial Addition/Alteration PermitWithdrawn
1999T99CM04022Commercial Addition/Alteration PermitCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11706168A — 102 City permits on file from 1999 to 2026 — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.