Electrical permit history — 510 N 7th Av

510 N 7th Av, Tucson — built 1945, with 25 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

510 N 7th Av

Built 1945 — 1940s commercial stock · 25 permits on record; no permitted panel/service or HVAC work among them

Parcel
117042490
Built
1945 (county record)
Jurisdiction
Tucson
Zoning
C-3
Assessor use
Warehousing
Parcel size
0.29 acres
Sewer
Connection on file (2016) (county sewer connection records)
Flood zone
AE — Special Flood Hazard Area (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 510 N 7th Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2018 (8 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T18FC00467 — RELOCATE THREE (3) HEADS
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2016. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2023-10-30 (TC-COM-1023-02545) — New non-structural framing and addition of electrical receptacles to existing tenant space. New tenant use as B Business Group existing Commercial / Retail..

Permit history (25)

Permit history for this parcel — 8 of 25 records
DateRecordWhatStatusValue
2023-10-30expired 2024-04-27TC-COM-1023-02545City permit recordPool / spaNew non-structural framing and addition of electrical receptacles to existing tenant space. New tenant use as B Business Group existing Commercial / Retail.Expired
2021-03-05finaledT21RW01048City permit recordROWW/O# 21R0597 - REPAIR LEAKING SERVICE ON WEST SIDE OF LOT IN DIRT ROAD @ 8 LF. EMERGENCY AFTER THE FACT.Final
2019-09-18finaledT19RW05339City permit recordROWStarting at TEP pole on the N/W corner of 6th St riser up and overlash 125' going North and riser down. Trench/bore 15' going West to out of ROW.Final
2018-06-08finaledT18CM04492City permit recordCOMBORETAILC of o
2018-06-08T18OT00621City permit recordFLOODPLNFUP FOR T18CM04492Issued
2018-06-05finaledT18FC00467City permit recordFIRECONSRELOCATE THREE (3) HEADSFinal
2017-11-22finaledT17CM08704City permit recordCOMBOELECTRIC RECONNECTFinal
2017-02-24finaledT17FC00160City permit recordFIRECONSAdd 3 fire sprinklersFinal
Show 17 older records
Permit history for this parcel — remaining 17 records
DateRecordWhatStatusValue
2017-02-16finaledT17OT00179City permit recordC-OF-OOFFICEC of o
2017-01-27finaledT17OT00110City permit recordC-OF-OOFFICEC of o
2016-11-22finaledT16CM08793City permit recordElectrical reconnectELECTRICAL RECONNECTFinal
2016-10-21finaledT16CM08015City permit recordCOMBORETAILC of o
2016-10-21finaledT16OT01287City permit recordFLOODPLNFUP - T16CM08015Final
2016-07-05finaledT16BU01013City permit recordSPKLRSPRINKLERFinal
2016-05-12expired 2023-04-10T16BU00753City permit recordSPKLRADD 3 SPRINKLERSClosed
2015-08-14finaledT15BU00935City permit recordSPKLRSPRINKLERSFinal
2015-08-07finaledT15OT01039City permit recordC-OF-OBUSINESSC of o
2015-08-07finaledT15OT01040City permit recordC-OF-OBUSINESSC of o
2015-08-07finaledT15OT01041City permit recordC-OF-OBUSINESSC of o
2015-08-07finaledT15OT01042City permit recordC-OF-OOFFICEC of o
2015-08-07finaledT15OT01043City permit recordC-OF-OOFFICEC of o
2015-05-07expired 2015-11-07DP15-0078City permit recordDevelopment PackageFUTURE CURE SITE PLANIssued
2015-01-13expired 2015-07-20DP15-0003City permit recordDevelopment PackageCANOPYIssued
2015-01-13finaledT15OT00052City permit recordFLOODPLNFPUP: CanopiesFinal
2015-01-05expired 2017-08-15T15CM00077City permit recordFence / wallT.I;ADD DEMISING WALLS R3: change fixture model for wall packs.Expired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (4)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 4 of 4 records
DateRecordWhatStatus
2024-08-12CE-VIO0824-03196Code enforcement caseWork without permitClosed - unfounded
2014-11-19T14DV09558Code enforcement caseGraffitiComplian
2014-08-18T14DV06176Code enforcement caseGraffitiReferred
2013-10-15T13DV07730Code enforcement caseGraffitiComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 117042490 — 25 permits on file from 2015 to 2023 (7 c-of-o, 3 combo, 3 floodpln, 3 spklr) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.