Electrical permit history — 325 W 2nd St
325 W 2nd St, Tucson — built 1973, with 47 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
325 W 2nd St
Built 1973 — 1970s commercial stock · 47 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 325 W 2nd St (aztucsonelectricalsolutions.com/property/11703180a/325-w-2nd-st-tucson-az-85705) · Public records last checked 2026-08-16
- Parcel
- 11703180A
- Built
- 1973 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-2
- Assessor use
- Misc Commercial
- Parcel size
- 2.51 acres
- Building area
- 71,015 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- John Spring Neighborhood Historic District — National Register district (City of Tucson)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted this year (2026). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0226-00130 — Replacement of existing GAMEWELL FCI SNAC-6 with a new Honeywell HPF-PS6 panel and adding additional devices
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Solar was permitted here in 2018. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.
Most recent permit on record for this parcel: 2026-03-09 (TC-CFO-0326-00046) — This project needs the okay for a Temporary Certificate of Occupancy (TCO) from a Fire and Engineering Inspector and the TCO level for the building. Please schedule Fire Final and Engineering Final. Water Sterilization Report is also needed. Please sign-in to your TDC Online account and submit water report. Once okay is given for TCO and report is submitted and approved please re-request TCO. If you have any questions, please contact PDSD-Permits@tucsonaz.gov RENOV OF EXIST LOCKER ROOM INTO NEW BUSINESS CENTER. NEW BATHROOM, STRUCTURAL UPGRADES AT NORTHEAST CORNER OF BUILDING TO CORRECT SETTLEMENT..
Permit history (47)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-03-09 | TC-CFO-0326-00046City permit record | Certificate of OccupancyThis project needs the okay for a Temporary Certificate of Occupancy (TCO) from a Fire and Engineering Inspector and the TCO level for the building. Please schedule Fire Final and Engineering Final. Water Sterilization Report is also needed. Please sign-in to your TDC Online account and submit water report. Once okay is given for TCO and report is submitted and approved please re-request TCO. If you have any questions, please contact PDSD-Permits@tucsonaz.gov RENOV OF EXIST LOCKER ROOM INTO NEW BUSINESS CENTER. NEW BATHROOM, STRUCTURAL UPGRADES AT NORTHEAST CORNER OF BUILDING TO CORRECT SETTLEMENT. | Denied | |
| 2026-02-25finaled | TF-FCP-0226-00130City permit record | Addition / alterationReplacement of existing GAMEWELL FCI SNAC-6 with a new Honeywell HPF-PS6 panel and adding additional devices | Complete | |
| 2026-01-22 | TR-ROW-0126-00075City permit record | Right-of-Way (ROW)Damaged Sidewalk Requiring Repair CarteGraph OMS Requeste #118739 | Void | |
| 2026-01-13finaled | TR-ROW-0126-00028City permit record | Right-of-Way (ROW)Violation of Tucson City Code Chapter 25 Section 25-12 Damaged Sidewalk Requiring Repair OMS Request Number: 118739 | Complete | |
| 2026-01-09 | TR-UTL-0126-00067City permit record | Right-of-Way (ROW) - UtilityCitation for sidewalk repair OMS Request #118739 | Void | |
| 2025-09-26finaled | TF-FCP-0925-00861City permit record | Fire ConstructionAdd 73 heads at office expansion | Complete | |
| 2025-09-18finaled | TF-FOP-0925-01244City permit record | Fire OperationalCabooret 2025 Concert and Silent Auction Fundraiser Tuan M Vo 520-395-7229 | Complete | |
| 2025-08-07expired 2026-02-20 | TF-FCP-0825-00639City permit record | Fire ConstructionModify existing fire sprinkler system | Expired |
Show 39 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-07-16 | TF-FOP-0725-00974City permit record | Fire OperationalVOID - Submit a month before event - CaBooret 2025 Concert and Silent Auction for Reveille Men's Chorus (non profit organization). Day of event contact: Tuan M Vo 520-395-7229 | Void | |
| 2025-05-27expired 2026-04-27 | TC-COM-0525-01056City permit record | Pool / spaTENANT IMPROVEMENT TO RENOVATE (2) CURRENTLY DISUSED ROOMS IN EXISTING, OCCUPIED DUNBAR SCHOOL BUILDING. WORK INCLUDES NEW MECHANICAL, ELECTRICAL AND LIGHTING AS WELL AS PATCHING, PAINTING AND FLOOR COVERINGS. ALL EXITS AND DOORS ARE EXISTING, THERE IS NO CHANGE TO EGRESS. NO PLUMBING WORK. ALL RESTROOMS ARE EXISTING. REWORK EXISTING FIRE SPRINKLER SYSTEM TO CONNECT TO NEW CEILING NO EXTERIOR WORK. NO STRUCTURAL WORK. REV1_A bathroom has been added to tenant space A119. This includes plumbing for a new toilet and sink, a new tankless water heater, exhaust fan, lights and bathroom accessories. Sheets below have been updated and new ones included to represent the added scope of work. Revised or Added (*) Sheets: G-100 – DUNBAR BUILDING TITLE SHEET A-A110 – FLOOR PLAN – LEVEL 1 TI A-A111 – ENLARGED PLANS AND INTERIOR ELEVATIONS A-A111.1 – TENANT SPACE BATHROOM INTERIOR ELEVATIONS A-A112 – LEVEL 1 RCP - TI A-A501 – WALL TYPES AND MILLWORK MD101 – MECHANICAL DEMOLITION FLOOR PLAN M101 – MECHANICAL FLOOR PLAN M201 – MECHANICAL ROOF PLAN M301 – MECHANICAL EQUIPMENT SCHEDULES, CALCULATIONS P001 – PLUMBING GENERAL INFORMATION P101 – PLUMBING FLOOR PLAN P201 – PLUMBING ISOMETRICS E101 – ELECTRICAL FLOOR PLANS E301 – ELECTRICAL ONE-LINE AND SCHEDULE | Issued | |
| 2025-02-26expires 2026-10-12 | TC-COM-0225-00389City permit record | Commercial BuildingRENOV OF EXIST LOCKER ROOM INTO NEW BUSINESS CENTER. NEW BATHROOM, STRUCTURAL UPGRADES AT NORTHEAST CORNER OF BUILDING TO CORRECT SETTLEMENT. | Issued | |
| 2024-12-18finaled | TR-ROW-1224-01434City permit record | Right-of-Way (ROW)temporary sidewalk closure | Complete | |
| 2024-10-24 | TC-COM-1024-02046City permit record | Commercial BuildingRe- roof Pulling off current tile and replacing tile with steal coated metal tile | Expired | |
| 2024-09-17expired 2024-10-20 | TF-FOP-0924-01065City permit record | Fire OperationalVoid- no longer needs a permit. A Cabaret and Silent Auction Fundraiser - special event - organizer | Withdrawn | |
| 2024-09-12finaled | TR-UTL-0924-01739City permit record | Right-of-Way (ROW) - UtilityCox to overlash 255' for system tie. | Complete | |
| 2023-11-06finaled | TF-FOP-1123-01734City permit record | Fire OperationalHarambee Festival | Complete | |
| 2023-01-31finaled | TF-FOP-0123-00430City permit record | Fire OperationalWe are hosting a festival on campus. A market will be held near the basketball court. A Read-In will be held in the auditorium and a film festival will be held in the dining room | Complete | |
| 2022-11-29finaled | TF-FCP-1122-00162City permit record | Fire ConstructionRelocating fire sprinkler heads | Complete | |
| 2022-06-13finaled | T22FC00406City permit record | Addition / alterationFire Alarm & Detection Systems - Auditorium TI - Install new smoke above fire alarm panel, new strobe in office room, change wall mount a/v to ceiling mount a/v.; Fire Alarm Systems - Devices Modified: 4; Additional Plan Reviews: 2; Work Started Without Approved Permit | Complete | |
| 2021-04-13finaled | T21FO00217City permit record | FIREOPERBARBEA WILLIAMS DANCE AND ARTS ACADEMY | Final | |
| 2021-01-21finaled | T21CM00638City permit record | Commercial BuildingC of O- Interior renovation of auditorium and front office. | Complete | |
| 2020-03-09finaled | T20RW01529City permit record | ROWStarting on the S/W corner of W. 2nd St and N. 11th Ave at TEP pole, riser down pole and trench /bore West 30' then South 15' to out of row Expired existing permit T19RW07743 NOTES: This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Please contact Allison Diehl at allison.diehl@tucsonaz.gov with any questions. | Final | |
| 2020-03-06expired 2021-04-13 | T20FC00156City permit record | Fire ConstructionFire Alarm & Detection Systems - New 4007 Fire Alarm panel/4003 Voice Panel in Dunbar West; Fire Alarm Systems - New Sq Ft: 11000 | Expired | |
| 2020-02-20finaled | T20FC00123City permit record | FIRECONSRELOCATE 28 PENDENTS | Final | |
| 2020-02-18finaled | T20CM01100City permit record | COMBOTI: EDUCATIONAL BLDG | L of c | |
| 2020-01-17finaled | T20RW00319City permit record | ROW2 5x5 bellholes in concrete/blktop front--- to repair gas line NOTES: OTHER PROJECTS/ACTIVITIES ACTIVE IN AREA, AS A CONTRACTOR YOU MUST COORDINATE WITH EXISTING TRAFFIC CONTROLE AND WORKERS. This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Please contact Allison Diehl at allison.diehl@tucsonaz.gov with any questions. | Final | |
| 2020-01-10expired 2020-07-12 | T20CM00204City permit record | Residential Building - One or Two FamilyREPAIR/REPL GAS LINE | Expired | |
| 2019-12-26finaled | T19RW07743City permit record | ROWStarting on the S/E corner at TEP pole, riser down and Trench/ bore West 60' Placing new Cox PED, continue trench/bore West 5' to out of row Existing expired permit #T19RW06364 NOTES: This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Please contact Allison Diehl at allison.diehl@tucsonaz.gov with any questions. | Final | |
| 2018-10-10finaled | T18RW04583City permit record | ROWStarting at TEP pole East of N. Mann Ave on the and South of W. 2nd Street trench/bore going South 20' to out of ROW. Riser up TEP pole and overlash 380' going East, continue going South 470' continue East 440' and Riser down, trench/bore going West 50' and Install a distribution vault. | Final | |
| 2018-09-24finaled | T18FC00786City permit record | Addition / alterationADDITION OF 3 DUCT DETECTORS TO FIRE ALARM SYSTEM. | Final | |
| 2018-09-24finaled | T18RW04272City permit record | ROWINSTALL TWO WATER HARVESTING BASINS IN BACK OF CURB AREA AND TWO CURB CUTS, ALONG THE NORTH SIDE OF UNIVERSITY BL IN FRONT OF THE DUNBAR SPRING COMMUNITY GARDEN, JUST WEST OF 11th AV. EXCAVATION COMPLETED USING PARKING LANE ALONG (WIDE) STREET. PROJECT IS LOCATED ON W UNIVERSITY BL AND 11TH AV. ** PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTAINED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. ** | Final | |
| 2018-08-17finaled | T18FC00692City permit record | FIRECONSRELOCATE 9 PENDENTS | Final | |
| 2018-07-05finaled | T18CM05242City permit record | Solar PVSOLAR | Final | |
| 2018-05-17expired 2019-03-06 | T18CM03842City permit record | COMBOCLASSROOM | Expired | |
| 2017-09-19expired 2017-12-24 | T17RW04163City permit record | ROWStarting on the South Side of W. 22nd St at TEP pole, Riser Dawn Pole and Place a 3x3x3 pothole if needed for a Trench/ Bore West for 65' Placing another 3x3x3 Pothole If Needed, then South 15' To Out of Row 10/10/2017-PLAN CHANGE Please renew Existing permit # T17RW04163 Plan change (From:)Starting on the South Side of W. 22nd St at TEP pole, Riser Dawn Pole and Place a 3x3x3 pothole if needed for a Trench/ Bore West for 65' Placing another 3x3x3 Pothole If Needed, then South 15' To Out of Row (TO:)Starting on the S/W corner of W. 22nd St and N. Main Ave at TEP pole, Overlash to Existing Strand for 275' Riser Dawn Pole and Place a 3x3x3 pothole for a Trench/ Bore West for 65' Placing another 3x3x3 Pothole, then South 15' To Out of Row | Expired | |
| 2012-10-25 | T12EX00567City permit record | EXCAVREPAIR MANHOLE AT INTERSECTION 2ND ST / MAIN AV | Closed | |
| 2012-01-11finaled | T12BU00035City permit record | SPKLRAdd 9 fire sprinklers | Final | |
| 2011-10-07expired 2012-04-28 | T11BU01313City permit record | SPKLRAdd 9 fire sprinklers | Expired | |
| 2011-08-29finaled | T11BU01124City permit record | BUILDREMODEL FIRE ALARM SYSTEM | Final | |
| 2011-05-06finaled | T11CM01371City permit record | COMBOTI: CLASSROOMS | Final | |
| 2011-01-06finaled | T11CM00038City permit record | COMBOROOF REPAIR | Final | |
| 2009-12-31finaled | T09BU01916City permit record | SPKLRRelocate 3 fire sprinklers | Final | |
| 2009-12-09finaled | T09BU01807City permit record | SPKLRInstall 45' of 4" underground & 231 fire sprinklers | Final | |
| 2009-10-22finaled | T09BU01578City permit record | BUILDFIRE ALAZRM SYSTEM | Final | |
| 2009-07-10finaled | T09CM01802City permit record | COMBOTI:2ND FLOOR | Final | |
| 2009-02-06expired 2012-12-05 | T09CM00294City permit record | COMBOTI: CLASSROOM | Expired | |
| 2008-04-18finaled | T08BU00748City permit record | SPKLRINSTALL 44 FIRE SPRINKLERS | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2024-01-31 | CE-VIO0124-00432Code enforcement case | Vegetation | Closed - resolved |
| 2009-05-18 | T09FR01744Code enforcement case | Code enforcement case | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 11703180A — 47 permits on file from 2008 to 2026 (6 row, 6 combo, 5 fire operational, 5 spklr) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.