Electrical permit history — 243 E University Bl

243 E University Bl, Tucson — built 1906, with 8 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

243 E University Bl

Built 1906 — 1900s multifamily stock · last permitted panel/service work 2006 (finaled)

Parcel
117030740
Built
1906 (county record)
Jurisdiction
Tucson
Zoning
HR-3
Assessor use
Apartments 5 - 24 Units 1 Story
Parcel size
0.28 acres
Building area
2,624 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
West University Historic District — Historic Preservation Zone — Contributing (City of Tucson)
Service on record
City records show the 2006 permit was finalized; the permit description states “UPGRADE:ELECTRIC TO 125 AMP R1 - Elec upgrade 125amp to unit 2,3,4” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 243 E University Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2006 (20 years ago). City inspection record: ELECTRIC - FINAL approved 2006-10-25. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T06EL02058 — UPGRADE:ELECTRIC TO 125 AMP R1 - Elec upgrade 125amp to unit 2,3,4
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2019-02-08$425,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-06-03 (TC-COM-0626-00808) — upgrade electric to 200 amps.

Permit history (8)

Permit history for this parcel — 8 of 8 records
DateRecordWhatStatusValue
2026-06-03finaledTC-COM-0626-00808City permit recordCommercial Buildingupgrade electric to 200 ampsComplete
2026-05-21TC-RES-0526-02710City permit recordResidential Building - One or Two FamilyWe request permission ot build two pergolas, one built-in BBQ, and a natural gas fire pit.In review
2026-03-09finaledTR-ROW-0326-00272City permit recordRight-of-Way (ROW)On Sunday, April 12th, Living Streets Alliance will host its 24th Cyclovia Tucson event, having participants enjoy one of Tucson's Bike Boulevards from Downtown to Amphi. It connects the neighborhoods of West University, Feldman's, Sugar Hill, Keeling, Amphi which are part of Ward 3 and Ward 6. The route will also have activities at Doris J. Thompson Park and the smaller park, Catalina Park. Over 45 other nonprofit organizations and NGOs, local businesses, and community partners will bring the 3.25 route to life, providing a free, fun, car-free day for an anticipated 40,000 people from across the region to enjoy. Traffic control set up and take down: Setup: 4am - Take Down: 315pmComplete
2020-11-09S20-065SubdivisionSubdivision/PlatsWest University SubdivisionNeeds Resubmittal
2020-11-02T20BU00501City permit recordFence / wall36" tall wrought iron fence across front of property.Expired
2010-08-24expired 2010-10-23T10EX00426City permit recordEXCAVEXCA:REMOVE & REPLACE 65LF OF 5'WIDE SIDEWALK & PLACING BRICK PAVERS IN BETWEEN THE SIDEWALK AND CURBClosed
2009-09-03finaledT09PL01475City permit recordPLUMBGAS LINE:REPLACE APTFinal
2006-10-12finaledT06EL02058City permit recordELECTUPGRADE:ELECTRIC TO 125 AMP R1 - Elec upgrade 125amp to unit 2,3,4Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (3)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 3 of 3 records
DateRecordWhatStatus
2016-10-03T16DV06823Code enforcement caseRefuseNoverify
2012-12-20T12DV11257Code enforcement caseCode enforcement caseComplian
2008-08-28T08DV07784Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 117030740 — 8 permits on file from 2006 to 2026 (1 commercial building, 1 residential building - one or two family, 1 right-of-way (row), 1 subdivision/plats) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.