Electrical permit history — 930 N 7th Av

930 N 7th Av, Tucson — built 1954, with 12 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

930 N 7th Av

Built 1954 — post-war 60–100 A service era · last permitted panel/service work 2022 (finaled)

Parcel
11702218D
Built
1954 (county record)
Jurisdiction
Tucson
Zoning
HR-3
Assessor use
Triplex - 1 Story
Parcel size
0.12 acres
Living area
1,880 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
West University Historic District — Historic Preservation Zone (City of Tucson)
Typical original service for a 1954 home
approximately 60–100 A
Service on record
City records show the 2022 permit was finalized; the permit description states “Replace evap coolers with ac, upgrade electrical panels with new distribution, replace existing elec This permit is for units A, B, C, D, E, F, G, H, I, J, K, L” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 930 N 7th Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 2022 (4 years ago). City inspection record: COT - LCME - Mechanical Final approved 2024-03-08. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T22CM04573 — Replace evap coolers with ac, upgrade electrical panels with new distribution, replace existing elec This permit is for units A, B, C, D, E, F, G, H, I, J, K, L
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
  • Plumbing work on recordOn recordLast permitted 2022 (4 years ago). Plumbing permits cover everything from a full re-pipe to a few feet of sewer repair, so this is a record that work happened rather than a statement about the whole system. T22RW02263 — SEWER LINE REPLACEMENT BEHIND 930 N 7TH AVE ON FERRO AVE

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2021. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2001-01-12$240,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2022-06-21 (T22RW02263) — SEWER LINE REPLACEMENT BEHIND 930 N 7TH AVE ON FERRO AVE.

Permit history (12)

Permit history for this parcel — 8 of 12 records
DateRecordWhatStatusValue
2022-06-21finaledT22RW02263City permit recordROWSEWER LINE REPLACEMENT BEHIND 930 N 7TH AVE ON FERRO AVEFinal
2022-06-18finaledT22CM04573City permit recordCommercial BuildingReplace evap coolers with ac, upgrade electrical panels with new distribution, replace existing elec This permit is for units A, B, C, D, E, F, G, H, I, J, K, LComplete
2022-02-25finaledT22CM01407City permit recordCommercial Building11 unit numbers are included on this permit. Plumbing drain and water line replacementComplete
2022-02-03finaledT22RW00368City permit recordROWEmergency – After the fact permit – a MCP was not provided due to the nature of the work. Any legal questions related to this work shall be directed to Southwest Gas to address since DTM did not have an opportunity to review, approve or inspect work. 2 5x5 bellholes in dirt/blktop front for crews to repair/replace/pothole gas line. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL.Final
2021-11-15finaledT21CM08868City permit recordCommercial BuildingRepair a section of sewer pipe located in backyard.Complete
2021-06-29finaledT21CM05372City permit recordCOMBOReconnect electrical in units B,C,D,F,G,H,I,J,K & LFinal
2018-12-10finaledT18CM09626City permit recordElectrical reconnectELECTRICAL RECONNECTFinal
2016-12-09finaledT16CM09218City permit recordCOMBOREPL GAS LINEFinal
Show 4 older records
Permit history for this parcel — remaining 4 records
DateRecordWhatStatusValue
2013-11-19finaledT13CM07027City permit recordCOMBOREPLACE GAS LINEFinal
2010-08-23finaledT10PL01338City permit recordPLUMBREPL GAS LINEFinal
2005-04-11finaledT05PL00688City permit recordPLUMBREPL: GAS LINE (APA)Final
2005-04-08T05PL00683City permit recordPLUMBREPLACE: GASPIPE (APA)Withdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (10)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 10 records
DateRecordWhatStatus
2025-04-22CE-VIO0425-01657Code enforcement caseCode enforcement caseClosed - resolved
2021-06-22T21DV03933Code enforcement caseRefuseReferred
2021-03-16T21DV01485Code enforcement caseSignClosed - resolved
2020-05-01T20DV03005Code enforcement caseWork without permitComplian
2019-06-12T19DV04755Code enforcement caseRefuseNoverify
2018-08-21T18DV04971Code enforcement caseCode enforcement caseComplian
2017-10-05T17DV05098Code enforcement caseRefuseComplian
2016-06-27T16DV03876Code enforcement caseCode enforcement caseComplian
Show 2 older records
Code enforcement history for this parcel — remaining 2 records
DateRecordWhatStatus
2015-05-13T15DV03579Code enforcement caseElectricalNoverify
2006-10-25T06DV01569Code enforcement caseCode enforcement caseVoid

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11702218D — 12 permits on file from 2005 to 2022 (3 commercial building, 3 combo, 3 plumb, 2 row) and 10 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.