Electrical permit history — 919 N Stone Av

919 N Stone Av, Tucson — built 1982, with 56 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

919 N Stone Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1982 — 1980s multifamily stock · last permitted panel/service work 2000 (finaled) · HVAC 2023 (permit expired without a confirmed final)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2000 (26 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T00EL02025 — SERVICE:NEW 100AMP
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “Opening a shaved iced dessert location in an existing restaurant. Alterations to include new paint, new furniture, counter modification, and placement of a condensing unit.”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. TC-COM-0123-00555 — Opening a shaved iced dessert location in an existing restaurant. Alterations to include new paint, new furniture, counter modification, and placement of a condensing unit.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2013 (13 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T13BU01123 — ADD 16 FIRE SPRINKLERS
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2000 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2003. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2023. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 36,904 sq ft (county building-footprint layer, 3 structures)
Usable for solar, planning estimate
≈ 25,800 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 280 kW — roughly 700 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 460,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$37,000–$60,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 2 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11702191G
Year constructed
1982 (assessor record)
Permitting authority
Tucson
Zoning
C-3
Property type
Apartments 100+ Units 3 Or More Story
Building area
77,516 sq ft
Cooling
WARMED AND COOLED AIR
Heating
Forced Air
Service on record
City records show the 2000 permit was finalized; the permit description states “SERVICE:NEW 100AMP”.

The building area, cooling and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 56 building permits for this parcel dated between 2000 and 2026. By category the work is permanent sign (15), addition / alteration (12), fire automatic extinguishing system (7) and annual portable sign compliance (7). 35 of them carry a final inspection; the other 21 were issued, expired or are still open, which is not the same as work completed. There are 8 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11702191G. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85705 · Commercial & industrial reports · Homes in 85705 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N STONE AV hold 4,116 City permits on record, 922 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (64 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TS-PRM-0126-00009Permanent Sign PermitAwaiting Submittal
2025CE-VIO0125-00140VegetationClosed - Resolved
2023CE-VIO1023-06214VegetationClosed - Resolved
2023TS-PRM-0323-00241Permanent Sign PermitExpired
2023recordROW Permit - City CIP/JOCComplete
2023T22CM06967Commercial Trade PermitComplete
2023TC-COM-0123-00555Commercial Addition/Alteration PermitExpired
2022T20OT00547Permanent Sign PermitExpired
2022T22DV03059Code enforcement caseClosed - Resolved
2021T21SA00452Zoning ComplianceComplete
2021T21SA00031Zoning ComplianceApproved
2020T20CM08741Commercial Addition/Alteration PermitExpired
2020T20FC00784Fire Automatic Extinguishing System PermitComplete
2020T20CM05534Commercial Addition/Alteration PermitComplete
2020T20DV06603LIGHTING VIOLATIONREFERRED
2020T20DV06540LIGHTING VIOLATIONCOMPLIAN
2019T19SA00343Zoning ComplianceComplete
2018T18SA00087Zoning ComplianceCanceled
2016T16DV06040PROP MAINT MULTIPLE TYPESCOMPLIAN
2013T13BU01123Fire Automatic Extinguishing System PermitComplete
2013T13DV07414REFUSENOVERIFY
2009T09OT02133Annual Portable Sign ComplianceCanceled
2009T09OT02085Annual Portable Sign ComplianceCanceled
2009T09OT01706Permanent Sign PermitComplete
2009T09OT01707Permanent Sign PermitComplete
2009T09OT01080Annual Portable Sign ComplianceComplete
2009T09OT01081Annual Portable Sign ComplianceCanceled
2009T09OT01079Annual Portable Sign ComplianceComplete
2009T09DV02077SIGN VIOLATIONCOMPLIAN
2009T09OT00542Permanent Sign PermitComplete
2009C10-03-36 Zoning ComplianceCanceled
2009C10-03-41 Zoning ComplianceCanceled
2009T09OT00300Permanent Sign PermitComplete
2009T09OT00369Annual Portable Sign ComplianceCanceled
2009T09OT00302Permanent Sign PermitComplete
2009T09OT00299Annual Portable Sign ComplianceComplete
2009T09BU00147Fire Automatic Extinguishing System PermitComplete
2009T08CM03971Commercial Addition/Alteration PermitCanceled
2009T08CM03972Commercial Addition/Alteration PermitCanceled
2005T05OT03228Permanent Sign PermitCanceled
2005T05BU01245Fire Automatic Extinguishing System PermitComplete
2005T05OT00983Permanent Sign PermitComplete
2005T05OT00982Permanent Sign PermitComplete
2005T05CM01624Commercial Addition/Alteration PermitComplete
2004T04BU02714Fire Automatic Extinguishing System PermitComplete
2004T04BU02602Commercial Trade PermitComplete
2004T04BU02185Commercial Trade PermitComplete
2004T04BU02186Commercial Trade PermitComplete
2004T04OT01519Permanent Sign PermitComplete
2004T04OT01520Permanent Sign PermitComplete
2004T04OT01521Permanent Sign PermitComplete
2004T03CM04345Commercial Addition/Alteration PermitComplete
2003T03BU01609Residential Pool/Spa PermitComplete
2003T03BU01317Fire Automatic Extinguishing System PermitComplete
2003T03BU01008Fire Automatic Extinguishing System PermitComplete
2003T03OT00720Permanent Sign PermitComplete
2002T01CM04187Commercial Addition/Alteration PermitComplete
2002T01CM04189Commercial New Building PermitComplete
2001T01OT00045Development PackageWithdrawn
2000T00CM05788Commercial Addition/Alteration PermitWithdrawn
2000T00CM05786Commercial Addition/Alteration PermitWithdrawn
2000T00CM05787Commercial Addition/Alteration PermitWithdrawn
2000T00CM04985Commercial Addition/Alteration PermitWithdrawn
2000T00EL02025Commercial Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11702191G — 56 City permits on file from 2000 to 2026 and 8 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.