Electrical permit history — 1010 S Freeway

1010 S Freeway, Tucson — built 1959, with 61 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

1010 S Freeway

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1959 — 1950s commercial stock · last permitted panel/service work 2017 (finaled); a newer 2021 permit is expired without a final

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundA newer 2021 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “60-amp disconnect in hazardous conditions must be replaced ASAP.Power kill needed to replace discon”. Last permitted 2017 (9 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T17CM00474 — REPLACE 200AMP METER BOX
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 special events fire permit - organizer permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2017 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

  • Routine

    A trade permit was pulled in 2017. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 25,712 sq ft (county building-footprint layer, 2 structures; 1 neighbouring structure crossing the lot line excluded)
Usable for solar, planning estimate
≈ 18,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 200 kW — roughly 500 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 330,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$26,000–$43,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 1.9 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11623142E
Year constructed
1959 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Motel W/ Restaurant/Lounge Facilities
Building area
32,580 sq ft
Service on record
City records show the 2017 permit was finalized; the permit description states “REPLACE 200AMP METER BOX”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 61 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (27), special events fire permit - vendor (9), special events fire permit - organizer (4) and addition / alteration (4). 38 of them carry a final inspection; the other 23 were issued, expired or are still open, which is not the same as work completed. There are 6 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11623142E. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85745 · Commercial & industrial reports · Homes in 85745 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S FREEWAY hold 203 City permits on record, 73 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (67 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026recordRight-of-Way (ROW) Permit - UtilityInspections
2026TF-FOP-0126-00090Special Events Fire Permit - OrganizerComplete
2026TF-FOP-1225-01676Special Events Fire Permit - VendorComplete
2026TF-FOP-1225-01555State Licensed Facility Operational Fire PermitComplete
2025recordRight-of-Way (ROW) Permit - UtilityComplete
2025TF-FOP-0125-00011State Licensed Facility Operational Fire PermitComplete
2024TF-FOP-1224-01530Special Events Fire Permit - VendorComplete
2024TC-DMO-1124-00261Commercial Demolition PermitExpired
2024TC-COM-1024-01960Commercial Trade PermitFees Due
2024TC-CFO-0824-00176Temporary Certificate-of-Occupancy (TCO)Issued
2024TF-FOP-1223-01961State Licensed Facility Operational Fire PermitComplete
2023TF-FOP-1223-01830Special Events Fire Permit - VendorComplete
2023TC-COM-0623-01460Commercial Addition/Alteration PermitComplete
2023TP-PRE-0823-00304Pre-Application ConferenceComplete
2023TC-DMO-0623-00146Commercial Interior Only Demolition PermitWithdrawn
2023TF-FOP-0123-00293Special Events Fire Permit - OrganizerComplete
2022T22OT00377Permanent Sign PermitComplete
2022T22OT00415Permanent Sign PermitComplete
2022T22FO00011Special Events Fire Permit - VendorComplete
2021T21CM03852Commercial Trade PermitExpired
2021T21FO00181Special Events Fire Permit - VendorComplete
2021T21DV02069ILLEGAL DUMPINGCOMPLIAN
2020T20FO00009Special Events Fire Permit - VendorComplete
2019T19OT00430Permanent Sign PermitComplete
2019T19DV02032ENVIRONMENTALCOMPLIAN
2019T19OT00205Permanent Sign PermitComplete
2019T19FO00011Special Events Fire Permit - OrganizerComplete
2019T18FO01137Special Events Fire Permit - VendorComplete
2018T18DV04957PROP MAINT MULTIPLE TYPESCOMPLIAN
2018T18DV02666PROP MAINT MULTIPLE TYPESNOVERIFY
2018T18FO00015General Operational Fire PermitComplete
2018T18FO00018Special Events Fire Permit - OrganizerComplete
2018T18FO00004Special Events Fire Permit - VendorComplete
2017T17CM00474Commercial Trade PermitComplete
2017T17FO00002Special Events Fire Permit - VendorComplete
2014T14DV03482REFUSECOMPLIAN
2012T12CM07519Commercial Trade PermitComplete
2012T12SA00276Marijuana Use AuthorizationCanceled
2011T11DV09369CLEAN CITIES INITIATIVE PGRMCOMPLIAN
2011T11SA00156Marijuana Use AuthorizationCanceled
2011T11OT00154Peddler PermitCanceled
2010T10EL00072Commercial Trade PermitComplete
2009T09EL00121Commercial Trade PermitComplete
2008T08EL00137Commercial Trade PermitCanceled
2007T07EL00087Commercial Trade PermitCanceled
2006T06EL00065Commercial Trade PermitCanceled
2005T05EL00074Commercial Trade PermitComplete
2004T04EL02499Commercial Trade PermitWithdrawn
2004T04EL02317Commercial Trade PermitComplete
2003T03OT00080Commercial Addition/Alteration PermitWithdrawn
2003T03EL00066Commercial Trade PermitComplete
2003T03EL00067Commercial Trade PermitComplete
2002T02EL00130Commercial Trade PermitComplete
2001T01CM02106Commercial Trade PermitCanceled
2001T01EL00067Commercial Trade PermitCanceled
2000T00EL02628Commercial Trade PermitComplete
2000T00EL01467Commercial Trade PermitCanceled
2000T00CM02725Commercial Addition/Alteration PermitCanceled
2000T00EL01294Commercial Trade PermitCanceled
2000T00EL01009Commercial Trade PermitComplete
2000T00EL00097Commercial Trade PermitWithdrawn
1999T99OT00319Commercial Addition/Alteration PermitWithdrawn
1999T99EL00125Commercial Trade PermitCanceled
1998T98EL01653Commercial Trade PermitCanceled
1998T98ME00541Commercial Trade PermitComplete
1998T98EL00142Commercial Trade PermitComplete
1997T97EL01342Commercial Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11623142E — 61 City permits on file from 1997 to 2026 and 6 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.