Electrical permit history — 777 W Cushing St
777 W Cushing St, Tucson — built 1970, with 29 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
777 W Cushing St
Built 1970 — 1970s commercial stock · 29 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 777 W Cushing St (aztucsonelectricalsolutions.com/property/11620037g/777-w-cushing-st-tucson-az-85745) · Public records last checked 2026-08-16
- Parcel
- 11620037G
- Built
- 1970 (assessor record)
- Jurisdiction
- Tucson
- Zoning
- C-3
- Assessor use
- Hotel
- Parcel size
- 7.45 acres
- Building area
- 85,097 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X (shaded) — 0.2% annual-chance flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-01-06 (TF-FOP-0126-00011) — Gem and Mineral trade show Chris Hartley 260 909 6996.
Permit history (29)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-01-06finaled | TF-FOP-0126-00011City permit record | Fire OperationalGem and Mineral trade show Chris Hartley 260 909 6996 | Complete | |
| 2025-12-09finaled | TF-FOP-1225-01594City permit record | Fire OperationalTents for Gem Show | Complete | |
| 2024-12-16finaled | TF-FOP-1224-01508City permit record | Fire OperationalTents - Gem Show | Complete | |
| 2024-12-16finaled | TF-FOP-1224-01511City permit record | Fire OperationalGem Show at hotel | Complete | |
| 2024-01-03finaled | TF-FOP-0124-00014City permit record | Fire OperationalPueblo Gem Show ar Ramada Inn | Complete | |
| 2023-12-28finaled | TF-FOP-1223-01983City permit record | Fire OperationalTents for Gem Show | Complete | |
| 2022-12-15finaled | TF-FOP-1222-00243City permit record | Fire OperationalTents for Gem Show vendors | Complete | |
| 2022-12-15finaled | TF-FOP-1222-00244City permit record | Fire OperationalGem Show operational permit | Complete |
Show 21 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2021-12-06finaled | T21FO00849City permit record | FIREOPER16 TENTS - PUEBLO GEM SHOW | Final | |
| 2021-04-08finaled | T21FO00215City permit record | FIREOPER6 TENTS + 5 HOURS | Final | |
| 2021-03-08finaled | T21FO00139City permit record | FIREOPER6 TENTS + 5 HOURS | Final | |
| 2020-09-29finaled | T20OT00660City permit record | Fence / wall1- illum wall sign | Complete | |
| 2019-12-31finaled | T19FO01140City permit record | FIREOPERgen show tents | Final | |
| 2019-01-09finaled | T19FO00029City permit record | FIREOPERRamada Inn - Riverpark Ballroom - 468/Cactus Rm - 296 | Final | |
| 2018-11-27finaled | T18RW05246City permit record | Addition / alterationPARTIAL SIDEWALK CLOSURE - WORK WILL BE DONE FROM A CRANE ON PRIVATE PROPERTY. APPLICANT SHALL KEEP AT LEAST A 4 FOOT CLEAR PATH ON THE SIDEWALK FOR PEDESTRIANS. IN ADDITION, NO PART OF THE CRANE SHALL BE OVERHEAD OF THE SIDEWALK. | Final | |
| 2018-10-31finaled | T18FO00940City permit record | FIREOPERGEM SHOW - 12 TENTS SET-UP 11/5/2018 EVENT DATES 01/20 - 2/15/2109 ONSITE CONTACT: CHRIS 909-6996 | Final | |
| 2018-10-04expired 2019-04-14 | T18CM07892City permit record | COMBOELECTRIC SIGN REPAIR | Expired | |
| 2018-09-26finaled | T18CM07666City permit record | COMBOELECTRIC WORK FOR SIGN | Final | |
| 2018-07-06finaled | T18OT00722City permit record | Sign - PermanentMonument sign cabinet replacements (new sign) request to keep structure, SDRC review (sign setback/a | Complete | |
| 2018-06-01expired 2019-07-14 | T18OT00587City permit record | Sign - PermanentUPDATE - now only freeway sign cabinet replacements (south side of site)(separate permit for mon | Expired | |
| 2018-04-03finaled | T18OT00366City permit record | Sign - Permanentchange copy / via temporary saddle covers (freeway sign and SF sign) | Inspections complete | |
| 2017-12-27finaled | T17FO01101City permit record | FIREOPERCactus Ballroom - OCC Load - 296/River Park Room - OCC Load - 468 | Final | |
| 2017-12-21finaled | T17FO01089City permit record | FIREOPERGEM SHOW - 12 TENTS SET-UP DATE 12-21-2017 ONSITE CONTACT: CHRIS - 909-6996 | Final | |
| 2017-06-08finaled | T17RW02452City permit record | ROWTRAFFIC SIGNAL POLE AND EQUIPMENT REPAIR ON CUSHING ST AND EAST BOUND FRONTAGE RD. THE POLE IS ON THE EAST END OF THE MEDIAN ISLAND. MAY HAVE TO SET TRUCK ON WEST BOUND LANE. | Final | |
| 2016-11-09finaled | T16FO00101City permit record | FIREOPERTents for Gem Show 18 tents Set-up 11/09/2016 Tear-down 03/01/2017 Contact: Chris Hartley 909-6996 | Final | |
| 2016-10-27finaled | T16RW02251City permit record | ROWREMOVING PTZ CAMERA FROM STREET LIGHT POLE AND MOVING TO A NEW LOCATION | Final | |
| 2015-12-31expired 2016-07-03 | T15BU01505City permit record | TENTSTENT | Expired | |
| 2015-01-23finaled | T15BU00076City permit record | TENTSTENT FOR GEM SHOW | Final | |
| 2014-01-31finaled | T14BU00118City permit record | TENTSTENT | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2019-07-18 | T19DV05782Code enforcement case | Code enforcement case | Complian |
| 2019-07-11 | T19DV05612Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 11620037G — 29 permits on file from 2014 to 2026 (9 fireoper, 8 fire operational, 3 sign - permanent, 3 tents) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.