Electrical permit history — 475 N Granada Av

475 N Granada Av, Tucson — built 1960, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

475 N Granada Av

Built 1960 — 1960s multifamily stock · 20 permits on record; no permitted panel/service or HVAC work among them

Parcel
11619175D
Built
1960 (assessor record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Apartments 100+ Units 3 Or More Story
Parcel size
10.46 acres
Building area
122,665 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 475 N Granada Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2024 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Interior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems”. Last permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22CM03720 — Interior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2023. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2026-02-12 (TZ-CMP-0226-00023) — Please provide a Zoning Verification Letter with zone designation, abutting zones and permitted use and copies of Variances and or Special and Conditional Use Permits..

Permit history (20)

Permit history for this parcel — 8 of 20 records
DateRecordWhatStatusValue
2026-02-12finaledTZ-CMP-0226-00023City permit recordZoning Verification LetterPlease provide a Zoning Verification Letter with zone designation, abutting zones and permitted use and copies of Variances and or Special and Conditional Use Permits.Complete
2025-01-24applied 2024-09-12 · expired 2025-03-11TC-COM-0924-01773Commercial buildingTrade permitEV Charging station associated with T22CM03725 - reviews and inspections completed under previous permitIssued
2024-11-14applied 2024-09-11 · finaledTC-COM-0924-01754Commercial buildingAddition / alterationGas piping for tenant BBQsInspections Complete$3,000
2024-05-28applied 2024-03-06 · completed 2024-03-11TC-CFO-0324-00060Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)Interior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems28000 sq ftIssued$838,069
2024-05-03expired 2024-07-11TC-CFO-0524-00096Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)Interior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems28000 sq ftIssued$838,069
2024-01-11applied 2024-01-05 · expired 2024-03-10TC-CFO-0124-00004Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)Interior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems17000 sq ftIssued$838,069
2023-11-06applied 2023-09-18 · finaled 2024-10-28TC-COM-0923-02219Certificate of occupancyPool / spaRemodel Pool3534 sq ft · Presidio Palms Pool RemodelComplete$50,000
2023-10-30expired 2023-12-29TC-CFO-1023-00207Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)Interior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems6000 sq ftIssued$838,069
Show 12 older records
Permit history for this parcel — remaining 12 records
DateRecordWhatStatusValue
2023-09-18applied 2023-05-08 · expired 2024-12-28TS-PRM-0523-00298SignPermanent SignInstall a new illuminated freestanding sign at 12' tall and 46.98 square feet that identifies Presidio Palms and located in the exact same location as the existing Hotel Tucson freestanding sign along the Granada Avenue frontage.Issued
2023-08-30applied 2023-04-27 · finaled 2024-01-04TC-COM-0423-01154Certificate of occupancyAddition / alterationClubhouse improvements9173 sq ftComplete$164,646
2023-08-29applied 2023-03-14 · expired 2024-02-25TC-DMO-0323-00069Commercial buildingDemolitionInterior Demolition9173 sq ft · Presidio Palms Clubhouse DemolitionIssued
2023-04-11applied 2022-05-16 · finaled 2024-11-26T22CM03720Certificate of occupancyAddition / alterationInterior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems6000 sq ftComplete$838,069
2023-04-11applied 2022-05-16 · finaled 2025-01-08T22CM03721Certificate of occupancyAddition / alterationInterior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems17000 sq ftComplete$838,069
2023-04-11applied 2022-05-16 · finaled 2025-02-04T22CM03725Certificate of occupancyAddition / alterationInterior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems180 sq ftComplete$838,069
2023-04-11applied 2022-05-16 · finaled 2025-01-09T22CM03723Certificate of occupancyAddition / alterationInterior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems28000 sq ftComplete$838,069
2023-04-11applied 2022-05-16 · finaled 2024-11-12T22CM03719Certificate of occupancyAddition / alterationInterior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems9173 sq ftComplete$838,069
2023-03-15applied 2022-05-16 · finaled 2025-01-09T22CM03724Certificate of occupancyAddition / alterationInterior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems60570 sq ftComplete$838,069
2023-03-06applied 2022-05-16 · finaled 2024-11-27T22CM03722Certificate of occupancyAddition / alterationInterior renovation with exterior guardrail and egress work - new sprinkler and life-safety systems28000 sq ftComplete$838,069
2022-08-05DS22-15Design modificationZoning Verification LetterCity Center Development, TSMR - City Center - TSMR, Section 7-01.4.1.B A. Walkway / sidewalk.In Review
2016-05-17applied 2016-05-12 · expired 2016-11-13DP16-0083Development packageDevelopment PackageSITEIssued

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2026-03-06CE-VIO0326-01098Code enforcement caseCode enforcement caseClosed - resolved
2023-02-21closed 2023-02-21CE-VIO0223-02019Code enforcement caseCode enforcement caseClosed - Resolved

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11619175D — 20 permits on file from 2016 to 2026 (9 addition / alteration, 4 temporary certificate-of-occupancy (tco), 2 zoning verification letter, 1 trade permit) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.