Electrical permit history — 405 N Granada Av

405 N Granada Av, Tucson — built 1908, with 16 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

405 N Granada Av

Built 1908 — 1900s multifamily stock · last permitted panel/service work 2020 (finaled); a newer 2024 permit is issued

Parcel
11619040A
Built
1908 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Apartments 5 - 24 Units 1 Story
Parcel size
0.78 acres
Building area
7,357 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
El Presidio Historic District — National Register district (City of Tucson)
Service on record
City records show the 2020 permit was finalized; the permit description states “200 amp panel upgrade” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 405 N Granada Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentA newer 2024 permit for the same system is recorded as “Inspections” — The work was permitted, but final completion is not confirmed. The permit description states “New 200 amp panel installation”. Last permitted 2020 (6 years ago). City inspection record: BUILDING - FINAL approved 2021-04-05. Contractor of record: Just Energize It Electric. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T20CM08159 — 200 amp panel upgrade
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2020 residential building - one or two family permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofCurrentLast permitted 2016 (10 years ago). Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar. T16CM00203 — T16DV00146 ROOF REPLACEMENT

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2015-02-27$875,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-07-31 (TR-UTL-0726-01279) — PRJ319862-1: Cox to overlash 355' of existing CATV fiber & asphalt cut 37' to install new CATV fiber for system tie..

Permit history (16)

Permit history for this parcel — 8 of 16 records
DateRecordWhatStatusValue
2026-07-31TR-UTL-0726-01279City permit recordRight-of-Way (ROW) - UtilityPRJ319862-1: Cox to overlash 355' of existing CATV fiber & asphalt cut 37' to install new CATV fiber for system tie.Fees due
2025-11-19TC-RES-1125-05601City permit recordAddition / alterationRamada at common area Wrong permit type, the scope of work and building type require that this request be submitted under a Commercial Addition/Alteration Permit. This permit will be voided. For questions: Building_Official@tucsonaz.govVoid
2024-05-02expired 2025-02-05TC-COM-0524-00775City permit recordCommercial BuildingNew 200 amp panel installationInspections
2024-04-29expired 2024-10-26TC-RES-0424-02580City permit recordTrade permitVOID: CSN-Unable to process, wrong permit type. Submit a new application under Commercial Trade Permit. Property shows 3+ units attached and a building that has more than two addresses/units is considered commercial. All permits require bare minimum a site plan. Please submit a site plan showing the location of electric panel upgrade with your new permit submittal. This permit will be voided as it is not the correct permit type. For questions email building_official@tucsonaz.gov New 200 amp panelVoid
2020-11-18finaledT20CM08159City permit recordCOMBO200 amp panel upgradeFinal
2020-05-29finaledT20CM03299City permit recordResidential Building - One or Two FamilyREMODEL AND ADD SECOND FLOOR SFRInspections complete
2020-05-06expired 2021-03-29DP20-0099City permit recordAddition / alterationSITE - Hinchcliffe Shire, renovations and additions.Issued
2019-04-25finaledT19CM02947City permit recordCOMBOINTERIOR REMODEL AND NEW ROOFFinal
Show 8 older records
Permit history for this parcel — remaining 8 records
DateRecordWhatStatusValue
2018-11-20T18CM09177City permit recordCOMBOHOME RENOVATIONWithdrwn
2018-08-06finaledT18BU00463City permit recordFence / wallBLOCK WALL 6'Final
2016-07-29finaledT16CM05970City permit recordCOMBOELEC UPGRADE TO 200 AMPFinal
2016-05-20finaledT16CM03819City permit recordAddition / alterationRESIDENTIAL: REMODEL AND ADDITIONFinal
2016-01-11finaledT16CM00203City permit recordCOMBOT16DV00146 ROOF REPLACEMENTFinal
2016-01-11finaledT16OT00045City permit recordFLOODPLNFPUP-T16CM00203Final
2015-09-17finaledT15OT01259City permit recordFence / wallFPUP-WallFinal
2015-09-14finaledT15BU01062City permit recordFence / wallZON/ENG WALL UP TO 6 FTFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (3)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 3 of 3 records
DateRecordWhatStatus
2018-06-22T18DV03655Code enforcement caseCode enforcement caseComplian
2016-01-05T16DV00046Code enforcement caseWork without permitComplian
2007-10-11T07DV10869Code enforcement caseVegetationComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11619040A — 16 permits on file from 2015 to 2026 (5 combo, 3 addition / alteration, 3 fence / wall, 1 right-of-way (row) - utility) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.