Electrical permit history — 338 N Granada Av

338 N Granada Av, Tucson — built 1909, with 15 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

338 N Granada Av

Built 1909 — 1900s commercial stock · 15 permits on record; no permitted panel/service or HVAC work among them

Parcel
116190370
Built
1909 (county record)
Jurisdiction
Tucson
Zoning
O-3
Assessor use
Office Building 2 Story
Parcel size
0.47 acres
Building area
4,310 sq ft (assessor record)
Sewer
Connection on file (2017) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
El Presidio Historic District — National Register district — Contributing (City of Tucson)

See the property

County aerial photograph centered on 338 N Granada Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2012 (14 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T12BU01342 — Install 120' of 4" underground piping & 11 fire sprinklers
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2011. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2024-05-22$1,000,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-12-11 (TF-FOP-1225-01631) — Gem and mineral showcase.

Permit history (15)

Permit history for this parcel — 8 of 15 records
DateRecordWhatStatusValue
2025-12-11finaledTF-FOP-1225-01631City permit recordFire OperationalGem and mineral showcaseComplete
2025-01-08finaledTF-FOP-0125-00041City permit recordFire OperationalGranada Gallery - Gem ShowComplete
2024-03-29expired 2024-12-09TC-COM-0324-00558City permit recordCommercial BuildingInstallation of Roof mounted 22kW PV System / Load Side tapIssued
2024-02-27expired 2024-08-25TC-RES-0224-01134City permit recordSolar PVVOID: Wrong permit type. Given scope of work resubmit new application under "Commercial Solar". This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. 2. Provide plans with all pages sealed by qualified registrants for structural attachments and electrical installations. Installation of Roof Mounted 22.0kW PV System / Load Side TapVoid
2021-12-22finaledT21FO00901City permit recordFIREOPER1 TENT 1/6/7/22 & 1/7/22 FOR THE GRANADA GALLERY HOUSE.Final
2020-01-14finaledT20FO00032City permit recordFIREOPER1 Gem show tent 40'x82'.Final
2019-01-29finaledT19FO00107City permit recordFIREOPERGEM SHOW - Gallery Event 1/25 - 2/16Final
2012-12-17expired 2013-02-15T12EX00701City permit recordEXCAVEXTEND EXISTING DRIVEWAY OPENING BY +/- 10LF. ** DRIVEWAY OPENING NO TO EXCEED 30LF. ** SIDEWALK REPLACEMENT TO BE DETERMINED IN FIELD BY INSPECTOR. ** THIS PROJECT IS LOCATED IN AN ARCHEOLOGICAL SENSITIVITY ZONE.Closed
Show 7 older records
Permit history for this parcel — remaining 7 records
DateRecordWhatStatusValue
2012-12-14expired 2013-06-19T12BU01472City permit recordFence / wallFENCE 8'Expired
2012-11-14finaledT12BU01342City permit recordSPKLRInstall 120' of 4" underground piping & 11 fire sprinklersFinal
2012-07-19expired 2022-08-27DP12-0117City permit recordAddition / alterationSITE REVIEW FOR OFFICE ADDITIONExpired
2012-07-19expired 2013-07-22T12CM04374City permit recordAddition / alterationOFFICE ROOM ADDITIONExpired
2011-10-04finaledT11CM03178City permit recordCOMBOTI: OFFICEC of o
2011-10-04finaledT11OT01888City permit recordAddition / alterationFLOODPLAIN USE PERMIT: Room addition; TI and 8-foot wrought iron fence.Final
2011-07-29finaledT11EL02040City permit recordELECTRECONNECT:ELECTRIC BUSFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 116190370 — 15 permits on file from 2011 to 2025 (3 fireoper, 3 addition / alteration, 2 fire operational, 1 commercial building) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.