Electrical permit history — 1201 W Saint Marys Rd
1201 W Saint Marys Rd, Tucson — built 1974, with 47 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
1201 W Saint Marys Rd
Built 1974 — 1970s commercial stock · 47 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 1201 W Saint Marys Rd (aztucsonelectricalsolutions.com/property/11618340a/1201-w-saint-marys-rd-tucson-az-85745) · Public records last checked 2026-08-17
- Parcel
- 11618340A
- Built
- 1974 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Retail Strip Center
- Parcel size
- 0.36 acres
- Building area
- 3,785 sq ft (assessor record)
- Sewer
- Connection on file (1952, 1973, 2002) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 firecons permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 firecons permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00318 — Installation of a new Ansul fire suppression system
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2024-03-25 (TZ-CMP-0324-00038) — Zoning Letter.
Permit history (47)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-03-25finaled | TZ-CMP-0324-00038City permit record | Zoning Verification LetterZoning Letter | Complete | |
| 2023-03-22finaled | TR-UTL-0323-01148City permit record | Right-of-Way (ROW) - UtilityWO# 1416011_1201 W Saint Mary's rd 14-13-11. Replace missing hydrant in dirt easement 4LF | Complete | |
| 2021-04-30finaled | T21FC00318City permit record | FIRECONSInstallation of a new Ansul fire suppression system | Final | |
| 2021-04-14finaled | T21RW01755City permit record | ROWW/O# 2011378 - IN FRONT ON EAST SIDE IN ASPHALT RD @ 6 LF EMERGENCY BLUE STAKE - WORK COMPLETED ON 4/12/21 EMERGENCY AFTER THE FACT | Final | |
| 2021-03-22finaled | T21CM02583City permit record | COMBOReplacing kitchen hood and adding one oven in existing restaurant. | Final | |
| 2021-02-16finaled | T21RW00756City permit record | ROWBORE 96' TO PLACE 3-1.25" INNERDUCT. PLACE 2-30X48' HANDHOLES. LOCATED ON WEST SIDE OF N GRANDE AV JUST SOUTH OF W SAINT MARYS RD. CONTRACTOR SHALL CONTACT BEA PAULUS (520) 206-8826 WITH SUNTRAN 48 HRS PRIOR TO STARTING WORK | Final | |
| 2019-10-28finaled | T19RW06563City permit record | ROWJOB WILL REQUIRE ACCESS TO MH#10406 TO SPLICE FIBER | Final | |
| 2019-10-24finaled | T19RW06432City permit record | ROWACCESS MH #10406 TO PLACE FIBER. | Final |
Show 39 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2016-08-22finaled | T16RW01164City permit record | ROWTEP TO INSTALL EQUIPEMENT ON EXISTING POLE - NO EXCAVATING | Final | |
| 2016-01-25expired 2016-07-23 | T16OT00114City permit record | SIGNA-FRAME W/ TRE | Expired | |
| 2015-04-14expired 2016-02-08 | T15OT00494City permit record | SIGNBANNER | Expired | |
| 2013-02-25expired 2013-11-26 | T13OT00233City permit record | SIGN90 DAY BANNER 2/25/13 THRU 5/26/13 | Expired | |
| 2012-09-05finaled | T12OT01300City permit record | SIGNCHANGE OF COPY FOR DF 9/8/12 20722 | Final | |
| 2012-07-06finaled | T12OT01009City permit record | Fence / wall1- ILLUM WALL SIGN 20580 | Final | |
| 2012-06-22finaled | T12CM03713City permit record | COMBOTI: 1,813 S.F. OFFICE | C of o | |
| 2011-10-31expired 2012-10-14 | T11OT02046City permit record | SIGNBANNER; 90 DAYS, 11/01/11 - 01/30/12 | Expired | |
| 2011-08-01finaled | T11OT01513City permit record | SIGNBANNER: 90 DAYS AUG. 2 - OCT 31, 2011 | Final | |
| 2011-03-22finaled | T11OT00534City permit record | SIGNBANNER:90 DAYS 03-22-2011 - 06-20-2011 | Final | |
| 2011-03-15finaled | T11OT00497City permit record | SIGNBANNER; 45 DAY, 03/15/11 - 04/29/11 | Final | |
| 2011-03-15finaled | T11OT00498City permit record | SIGNBANNER; 45 DAY, 03/15/11 - 04/29/11 | Final | |
| 2010-04-16finaled | T10OT00821City permit record | SIGN18191 | Final | |
| 2010-04-16finaled | T10OT00822City permit record | SIGN18192 | Final | |
| 2010-01-27finaled | T10OT00194City permit record | SIGN17812 | Final | |
| 2010-01-20expired 2010-09-12 | T10OT00141City permit record | SIGN17805 | Expired | |
| 2010-01-05expired 2010-07-19 | T10OT00026City permit record | SIGN17742 | Closed | |
| 2009-10-20finaled | T09OT02251City permit record | SIGN17380 | Final | |
| 2009-06-22finaled | T09OT01278City permit record | SIGN16848 | Final | |
| 2009-05-01finaled | T09OT00878City permit record | SIGN16614 | Final | |
| 2006-05-26finaled | T06OT01429City permit record | SIGN11246 | Final | |
| 2006-01-19 | T06EL00105City permit record | ELECTNEW ELEC SERVICE | Withdrwn | |
| 2005-12-15 | T05AN01348City permit record | ADDRNEW | Issued | |
| 2005-09-06expired 2006-12-03 | T05CM04596City permit record | COMBOTI:LITTLE CAESARS | Expired | |
| 2005-08-08expired 2006-02-08 | T05OT01961City permit record | C-OF-OC OF O | Expired | |
| 2005-05-18expired 2006-04-18 | T05OT01272City permit record | SIGNSIGN:#9041 AUTO TITLE LOANS | Expired | |
| 2005-02-01finaled | T05CM00422City permit record | COMBOTI:OFFICE DEMO INTERIOR NON-BEARING PARTITIONS , ADD TWO ACCESSIBLE TOILET ROOMS, METAL STUDS W/ GYP BD. SEPARATE BUILDING PERMIT REQUIRED FOR TENANT IMPROVEMENT/ OCCUPANCY. | Final | |
| 2002-07-09expired 2003-04-23 | T02EL01396City permit record | ELECTELECTRIC:RECONNECT | Expired | |
| 2002-04-26finaled | T02EL00867City permit record | ELECTELECTRIC:ADD 1 CIRCUIT | Final | |
| 2002-03-15finaled | T02OT00405City permit record | SIGNSIGN:3762 | Final | |
| 2002-02-11finaled | T02OT00232City permit record | SIGNSIGN:#3628 | Final | |
| 2002-02-01expired 2002-10-08 | T02OT00186City permit record | SIGNSIGN:3622 | Expired | |
| 2002-01-25finaled | T02OT00153City permit record | SIGNSIGN:3596 | Final | |
| 2002-01-17 | T02AN00050City permit record | ADDRNEW | Issued | |
| 2002-01-17finaled | T02CM00270City permit record | COMBOTI:CHECK CASH CENTER | Final | |
| 2002-01-17finaled | T02CM00272City permit record | COMBOTI:OFFICE | Final | |
| 2002-01-17finaled | T02CM00276City permit record | COMBOTI:OFFICE | Final | |
| 2000-03-17expired 2000-10-22 | T00EL00673City permit record | ELECTSIGN:ELECTRIC:TS200003-649 | Expired | |
| 2000-02-24finaled | T00EL00482City permit record | ELECTSIGN:CIRCUIT:545 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (21)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2019-01-23 | T19DV00385Code enforcement case | Vegetation | Complian |
| 2015-08-06 | T15DV05795Code enforcement case | Work without permit | Complian |
| 2015-03-31 | T15DV02384Code enforcement case | Code enforcement case | Complian |
| 2015-02-18 | T15DV01088Code enforcement case | Sign | Complian |
| 2014-11-18 | T14DV09532Code enforcement case | Sign | Complian |
| 2014-09-24 | T14DV07857Code enforcement case | Code enforcement case | Complian |
| 2014-09-15 | T14DV07406Code enforcement case | Work without permit | Complian |
| 2014-09-03 | T14DV06900Code enforcement case | Code enforcement case | Complian |
Show 13 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2014-05-22 | T14DV03323Code enforcement case | Code enforcement case | Complian |
| 2013-01-22 | T13DV00472Code enforcement case | Code enforcement case | Complian |
| 2011-02-28 | T11DV01181Code enforcement case | Code enforcement case | Complian |
| 2010-08-12finaled | T10FR01697Code enforcement case | Fire | Complete |
| 2010-08-12finaled | T10FR01698Code enforcement case | Fire | Complete |
| 2010-08-12finaled | T10FR01699Code enforcement case | Fire | Complete |
| 2010-04-21 | T10DV02462Code enforcement case | Code enforcement case | Complian |
| 2009-03-10finaled | T09FR00886Code enforcement case | Code enforcement case | Complete |
| 2008-10-15finaled | T08FR03786Code enforcement case | Fire | Complete |
| 2008-10-15finaled | T08FR03787Code enforcement case | Fire | Complete |
| 2008-10-15finaled | T08FR03788Code enforcement case | Fire | Complete |
| 2006-11-07 | T06DV01983Code enforcement case | Sign | Complian |
| 2002-02-27 | T02VL00398Code enforcement case | Code enforcement case | Void |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 11618340A — 47 permits on file from 2000 to 2024 (23 sign, 7 combo, 5 row, 5 elect) and 21 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.