Electrical permit history — 405 W Speedway Bl
405 W Speedway Bl, Tucson — built 2024, with 21 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
405 W Speedway Bl
Built 2024 — 2020s commercial stock · 21 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 405 W Speedway Bl (aztucsonelectricalsolutions.com/property/116163130/405-w-speedway-bl-tucson-az-85705) · Public records last checked 2026-08-17
- Parcel
- 116163130
- Built
- 2024 (assessor record)
- Jurisdiction
- Tucson
- Zoning
- C-3
- Assessor use
- Convenience Store With Fuel Dispensing
- Parcel size
- 0.61 acres
- Building area
- 2,116 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0824-00711 — Installation of Underground Storage Tanks and related equipment
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2025-12-01 | $2,150,000 | Warranty Deed |
| 2022-07-07 | $1,325,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-06-26 (TR-UTL-0626-01059) — P.348976A OVERBUILD TRENCH 14' TO PLACE CONDUIT AND FIBER CABLE PLACE 1 PEDESTAL PLACE 4009' OF AERIAL FIBER CABLE.
Permit history (21)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-26 | TR-UTL-0626-01059City permit record | Right-of-Way (ROW) - UtilityP.348976A OVERBUILD TRENCH 14' TO PLACE CONDUIT AND FIBER CABLE PLACE 1 PEDESTAL PLACE 4009' OF AERIAL FIBER CABLE | Needs resubmittal | |
| 2025-10-27 | TC-CFO-1025-00159City permit record | Certificate of OccupancyThis project is not able to receive a TCO. Please request TCO under TC-COM-0723-01679 a County Health Inspection document is required and Building inspector must give okay for TCO. Any questions please email building_official@tucsonaz.gov Installation of underground storage tanks at a fuel station | Denied | |
| 2025-09-02finaled | TR-ROW-0925-01079City permit record | Right-of-Way (ROW)Mill and pave 200’L X 20” W X 2’ D for moritorium.*** | Complete | |
| 2025-07-11finaled | TR-ROW-0725-00901City permit record | Right-of-Way (ROW)Remove 4 drive entrances and Install 2 standard entrances, 4 standard Raps and 250’ of sidewalk and 1 sidewalk scupper.*** | Complete | |
| 2025-06-20finaled | TR-ROW-0625-00835City permit record | Right-of-Way (ROW)Trench 4’W X 4’D X4’L for new sewer tie in on Main. Continuation of Permit Number: TR-ROW-0325-00297*** | Complete | |
| 2025-06-08finaled | TS-PRM-0625-00241City permit record | Fence / wallTO INSTALL ONE NEW, ILLUMINATED WALL SIGN | Inspections complete | |
| 2025-04-28finaled | TR-UTL-0425-00695City permit record | Right-of-Way (ROW) - Utility3 water service abandonments, 2 water relocates, 2 new 1" services | Complete | |
| 2025-03-13 | TC-COM-0325-00496City permit record | Trade permit** VOID: YL- After further review, unable to process this as a Trade permit. The scope of work should be part of the existing Canopy permit TC-COM-1024-02083. This submittal will need to be voided and the purposed Border lighting should be added to the existing Canopy permit as a revision. For questions: Building_Official@tucsonaz.gov ** - Border lighting on the canopy. Please note we are not permitting the structure of the canopy because we are just adding a decorative skin with border lighting. We just need to show the attachment of the lighting to the canopy skin and we can provide a detail for that. This is kind of like if we were to add border lighting on a store or restaurant. | Void |
Show 13 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-03-03finaled | TR-ROW-0325-00297City permit record | Right-of-Way (ROW)Please submit. Trench 4’W X 4’D X4’L for mew sewer tie in on Main.*** | Complete | |
| 2025-02-26finaled | TR-ROW-0225-00277City permit record | Right-of-Way (ROW)Remove 4 drive entrances and Install 2 standard entrances, 4 standard Raps and 250’ of sidewalk and 1 sidewalk scupper.*** Permit update 4/2/2025: Renewal for 60 days. | Complete | |
| 2025-02-06finaled | TS-PRM-0225-00051City permit record | Sign - PermanentBW needs revisions, shell logo only, not stripes | Inspections complete | |
| 2025-02-04finaled | TR-UTL-0225-00203City permit record | Right-of-Way (ROW) - UtilityWO T132881 - TEP to replace pole in ROW, between curb & sidewalk. | Complete | |
| 2024-11-19finaled | TS-PRM-1124-00505City permit record | Sign - PermanentWaiting for the BUILDING PERMIT to be approved +paid | Inspections complete | |
| 2024-10-29finaled | TC-COM-1024-02083City permit record | Commercial BuildingAdd Canopy Installation for Gas dispensers | Complete | |
| 2024-08-26finaled | TF-FCP-0824-00711City permit record | Fire ConstructionInstallation of Underground Storage Tanks and related equipment | Complete | |
| 2024-08-26finaled | TF-FOP-0824-00971City permit record | Fire OperationalInstallation of Underground Storage Tanks and related equipment. | Complete | |
| 2024-08-23finaled | TC-COM-0824-01658City permit record | Commercial BuildingInstallation of underground storage tanks at a fuel station | Complete | |
| 2023-11-22 | TC-COM-1123-02710City permit record | Commercial BuildingGround up, new construction for a smoothie shop. | Expired | |
| 2023-09-11 | TD-DIV-0923-00105Subdivision | Subdivision/Plats20241790271 Minor Subdivision - 4 lots - Final Plat | In Review | |
| 2023-07-11finaled | TC-COM-0723-01678City permit record | Commercial BuildingNew Shell Building for Future Food Mart and Fuel Station | Complete | |
| 2023-07-11finaled | TC-COM-0723-01679City permit record | Commercial BuildingTI: Food Mart | Complete |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (1)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2024-06-11closed 2025-02-19 | CE-VIO0624-02250Code enforcement case | Code enforcement case | Closed - Resolved |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 116163130 — 21 permits on file from 2023 to 2026 (5 right-of-way (row), 5 commercial building, 3 right-of-way (row) - utility, 2 sign - permanent) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.