Electrical permit history — 1815 W Saint Marys Rd

1815 W Saint Marys Rd, Tucson — built 1985, with 8 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1815 W Saint Marys Rd

Built 1985 — 1980s commercial stock · 8 permits on record; no permitted panel/service or HVAC work among them

Parcel
11615190H
Built
1985 (county record)
Jurisdiction
Tucson
Zoning
O-3
Assessor use
Medical Clinic No Pharmacy
Parcel size
0.75 acres
Building area
4,159 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X (shaded) — area protected by levee (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1815 W Saint Marys Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (5)

Recorded transfers from the Pima County Assessor — 5 of 5
DatePriceType
2026-06-25$1,130,000Warranty Deed
2024-10-07$938,000Warranty Deed
2022-05-13$938,000Warranty Deed
2007-02-21$1,310,000Warranty Deed
2004-04-30$375,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-03-06 (TR-UTL-0326-00465) — WO T155282 (ST MARYS) - reconductor 3 spans of overhead, replace 4 wood poles with steel poles, replace 2 anchors, remove 1 anchor, replace 3 – 4” risers, install 5 new poles and 5 new spans of overhead, install 1 – 6” riser & WO T173264 (CAMINO SANTIAGO) - Install 1 – PME9, 1 – PME11, 2 – 6” risers, 2,140’ of cable 06/15/2026 - Request for 90 Day Renewal as of 06/23/2026.

Permit history (8)

Permit history for this parcel — 8 of 8 records
DateRecordWhatStatusValue
2026-03-06expires 2026-09-21TR-UTL-0326-00465City permit recordPool / spaWO T155282 (ST MARYS) - reconductor 3 spans of overhead, replace 4 wood poles with steel poles, replace 2 anchors, remove 1 anchor, replace 3 – 4” risers, install 5 new poles and 5 new spans of overhead, install 1 – 6” riser & WO T173264 (CAMINO SANTIAGO) - Install 1 – PME9, 1 – PME11, 2 – 6” risers, 2,140’ of cable 06/15/2026 - Request for 90 Day Renewal as of 06/23/2026Issued
2023-01-11expired 2023-07-10TS-PRM-0123-00114City permit recordFence / wall(1) New non-illuminated wall sign and (1) new non-illuminated monument sign (not an engineered sign)Issued
2022-06-13finaledT22FO00528City permit recordFIREOPEROUTPATIENT TREATMENT AND COUNSELING.Final
2019-12-13finaledT19RW07532City permit recordROWSTART POINT : CONTINUING FROM OUT OF ROW (1815 W ST MARY'S RD) 30' TRENCH /BORE PLACING 2X 2'' CONDUIT HEADING SOUTH, RISER UP TEP POLE AND BEGIN 252' OVERLASH HEADING EAST, CONTINUE 174' OVERLASH HEADING SOUTH, CONTINUE 276' OVERLASH HEADING NORTH EAST, 256' OVERLASH HEADING EAST TO TEP POLE TIE IN. This project is located in an ARCHAELOGICAL SENSITIVE ZONE. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Please contact Allison Diehl at allison.diehl@tucsonaz.gov with any questions.Final
2018-11-13finaledT18RW05060City permit recordROWStarting on the North side of Anklm Rd,East of St Mary's overlash going S/E for 350 to out of rowFinal
2005-09-21finaledT05OT02338City permit recordSIGNSIGN:# 9740 TUCSON VASCULAR SURGERYFinal
2005-03-04finaledT05OT00476City permit recordSIGNSIGN:8608 TUCSON VASCULAR SURGERYFinal
2005-03-03expired 2006-11-13T05OT00464City permit recordSIGNSIGN:8604 TUCSON VASCULAR SURGERYClosed

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2007-09-17T07DV09172Code enforcement caseRefuseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11615190H — 8 permits on file from 2005 to 2026 (3 sign, 2 row, 1 pool / spa, 1 fence / wall) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.