Electrical permit history — 1450 W Saint Marys Rd

1450 W Saint Marys Rd, Tucson — built 1988, with 17 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1450 W Saint Marys Rd

Built 1988 — 1980s commercial stock · 17 permits on record; no permitted panel/service or HVAC work among them

Parcel
116124850
Built
1988 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Restaurant Fast Food
Parcel size
0.15 acres
Building area
1,216 sq ft (assessor record)
Sewer
Connection on file (1987, 2007, 2026) (county sewer connection records)
Flood zone
X (shaded) — 0.2% annual-chance flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1450 W Saint Marys Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “EXPEDITE - Installation of a CO2 monitoring system for beverage dispensers.”. Last permitted this year (2026). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0126-00030 — To install 9gal Ansul Suppression System.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2023-11-30$475,000Warranty Deed
1999-03-24$232,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-03-18 (TF-FCP-0326-00184) — EXPEDITE - Installation of a CO2 monitoring system for beverage dispensers..

Permit history (17)

Permit history for this parcel — 8 of 17 records
DateRecordWhatStatusValue
2026-03-18expires 2026-09-27TF-FCP-0326-00184City permit recordFire ConstructionEXPEDITE - Installation of a CO2 monitoring system for beverage dispensers.Issued
2026-03-18TF-FCP-0326-00185City permit recordFire ConstructionVOID - Submit a Fire General Operational Permit - Installation of a CO2 monitoring system for beverage dispensers.Void
2026-03-18expires 2027-03-27TF-FOP-0326-00388City permit recordFire OperationalEXPEDITE - Installation of a CO2 monitoring system for Beverage dispensers.Fees paid
2026-01-19finaledTF-FCP-0126-00030City permit recordFire ConstructionTo install 9gal Ansul Suppression System.Complete
2026-01-12finaledTC-COM-0126-00044City permit recordCommercial Buildingremove and replace grase interceptor 320 gallonsComplete
2026-01-05finaledTS-PRM-0126-00003City permit recordFence / wallInstall 2 lighted wall signs, 3 non-lighted wall signs, replace panels in monument sign and replace cabinet for menu board.Inspections complete
2024-02-16expired 2024-08-14TS-PRM-0224-00068City permit recordSign - PermanentFabricate & Install Two Round Illuminated Boxes, Change Faces on Existing MonumentFees due
2021-09-09expired 2022-03-08T21CM07292City permit recordCommercial BuildingReplacement 200 A DisconnectExpired
Show 9 older records
Permit history for this parcel — remaining 9 records
DateRecordWhatStatusValue
2005-05-02finaledT05BU01059City permit recordBUILDEXHAUST HOOD: FIRE EXTINGUISHING SYSTEMFinal
2005-02-23finaledT05OT00399City permit recordSIGNSIGN:8561 LA FRESITOFinal
2004-12-22expired 2008-08-23T04OT02503City permit recordC-OF-OC OF O:LA FRESITAClosed
2004-01-29finaledT04OT00187City permit recordC-OF-OC OF O:RESTAURANTC of o
2004-01-09finaledT04OT00047City permit recordSIGNSIGN:ELECTRIC:6558Final
2000-06-09expired 2000-12-11T00EL01458City permit recordELECTSIGN:CIRCUIT:1064Expired
2000-05-31expired 2000-12-11T00EL01345City permit recordELECTSIGN:CIRCUIT:1002Expired
2000-03-07finaledT00CM01096City permit recordCOMBOTI:RESTAURANTC of o
2000-01-19expired 2000-08-20T00CM00222City permit recordDemolitionTI:RESTAURANT - INTERIOR DEMOLITIONExpired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (10)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 10 records
DateRecordWhatStatus
2025-01-27CE-VIO0125-00379Code enforcement caseVegetationClosed - resolved
2024-08-20CE-VIO0824-03317Code enforcement caseCode enforcement caseClosed - resolved
2020-03-26T20DV02000Code enforcement caseCode enforcement caseComplian
2018-05-21T18DV02892Code enforcement caseVegetationNoverify
2015-07-14T15DV05088Code enforcement caseRefuseComplian
2013-09-19T13DV07092Code enforcement caseCode enforcement caseComplian
2008-10-27finaledT08FR03940Code enforcement caseFireComplete
2005-01-26T05VL00091Code enforcement caseSignComplian
Show 2 older records
Code enforcement history for this parcel — remaining 2 records
DateRecordWhatStatus
2003-08-26T03DV00808Code enforcement caseCode enforcement caseComplian
2003-06-23T03ZV00038Code enforcement caseCode enforcement caseClosed

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 116124850 — 17 permits on file from 2000 to 2026 (3 fire construction, 2 commercial building, 2 sign, 2 c-of-o) and 10 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.