Electrical permit history — 2220 N Silverbell Rd

2220 N Silverbell Rd, Tucson — built 2013, with 37 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

2220 N Silverbell Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 2013 — 2010s multifamily stock · 1 open code case · 37 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2013 fire automatic extinguishing system permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service work shows in the record we read — unremarkable for a building of this age, whose service was sized to modern code at construction. The live question is spare capacity for new loads (EV charging, kitchen or process equipment), not the age of the gear. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2013 fire automatic extinguishing system permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2013 (13 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T13BU00780 — FIRE SPRINKLERS
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2013. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 35,722 sq ft (county building-footprint layer, 14 structures)
Usable for solar, planning estimate
≈ 25,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 280 kW — roughly 700 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 460,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$37,000–$60,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 4.5 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11520261A
Year constructed
2013 (assessor record)
Permitting authority
Tucson
Zoning
C-1
Property type
Apartments 25 - 99 Units Subsidized Low Inc
Building area
28,167 sq ft
Cooling
WARMED AND COOLED AIR
Heating
Forced Air

The building area, cooling and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2017. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2017. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 37 building permits for this parcel dated between 2005 and 2017. By category the work is fire automatic extinguishing system (11), new construction (11), zoning compliance (3) and trade permit (2). 29 of them carry a final inspection; the other 8 were issued, expired or are still open, which is not the same as work completed. There are 4 code-enforcement cases recorded against the parcel, 1 of which is open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11520261A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85745 · Commercial & industrial reports · Homes in 85745 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N SILVERBELL RD hold 2,178 City permits on record, 347 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (41 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0926-03924FireReceived
2019T19DV05724RESIDENTIAL ZONINGCOMPLIAN
2017T17BA00004Stormwater BasinApproved
2014T14OT00212Permanent Sign PermitComplete
2013T13BU00780Fire Automatic Extinguishing System PermitComplete
2013T13BU00631Commercial New Building PermitComplete
2013T13BU00622Fire Automatic Extinguishing System PermitComplete
2013T13BU00624Fire Automatic Extinguishing System PermitComplete
2013T13BU00625Fire Automatic Extinguishing System PermitComplete
2013T13BU00627Fire Automatic Extinguishing System PermitComplete
2013T13BU00601Fire Automatic Extinguishing System PermitComplete
2013T13BU00623Fire Automatic Extinguishing System PermitComplete
2013T13BU00626Fire Automatic Extinguishing System PermitComplete
2013T13BU00628Fire Automatic Extinguishing System PermitComplete
2013T13BU00629Fire Automatic Extinguishing System PermitComplete
2013T13BU00630Fire Automatic Extinguishing System PermitCanceled
2013T13CM02372Commercial Trade PermitComplete
2013T13CM01748Commercial Trade PermitComplete
2013T12CM00292Commercial New Building PermitComplete
2013T12CM00293Commercial New Building PermitComplete
2013T12CM00294Commercial New Building PermitComplete
2013T12CM00299Commercial New Building PermitComplete
2013T12CM00290Commercial New Building PermitComplete
2013T12BU00832GradingComplete
2013T12CM00291Commercial New Building PermitComplete
2013T12CM00295Commercial New Building PermitComplete
2013T12CM00296Commercial New Building PermitComplete
2013T12CM00297Commercial New Building PermitComplete
2013T12CM00298Commercial New Building PermitComplete
2013T12OT01004Floodplain Use PermitComplete
2012D11-0032Development PackageApproved
2012T12SA00242Zoning ComplianceComplete
2012S12-032 Land Split/Lot SplitComplete
2011T11BU01259GradingWithdrawn
2009T09SA00326Zoning ComplianceComplete
2009C9-81-23 RezoningWithdrawn
2008T08DV08940REFUSECANCEL
2008T08DV07150MULTIPLE TYPESNOVERIFY
2007S07-154 Subdivision/PlatsCanceled
2007T07SA00070Zoning ComplianceWithdrawn
2005S05-073 Subdivision/PlatsCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11520261A — 37 City permits on file from 2005 to 2017 and 4 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.