Electrical permit history — 1501 N Oracle Rd

1501 N Oracle Rd, Tucson — built 1963, with 65 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

1501 N Oracle Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1963 — 1960s commercial stock · last permitted panel/service work 2017 (finaled) · HVAC 2010 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2017 (9 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T17CM01532 — REPAIR/ REPLACE 200AMP
  • Heating, cooling & mechanicalLikely dueLast permitted 2010 (16 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T09CM03268 — CHILLER REPLACEMENT
  • Fire alarm & life safetyFinaled permit foundA newer 2026 permit for the same system is recorded as “Inspections” — The work was permitted, but final completion is not confirmed. The permit description states “Add New Fire Sprinkler System to an Existing 17 story Building”. Last permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22FC00526 — INSTALL A CELLULAR COMMUNICATOR TO MONITOR THE EXISTING BUILDING FIRE ALARM PANEL.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2017 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 1997. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2017. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 44,249 sq ft (county building-footprint layer, 5 structures; 1 neighbouring structure crossing the lot line excluded)
Usable for solar, planning estimate
≈ 31,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 340 kW — roughly 850 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 560,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$45,000–$73,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 2.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
115180220
Year constructed
1963 (assessor record)
Permitting authority
Tucson
Zoning
OCR-1
Property type
Municipal Residential Property
Building area
431,670 sq ft
Service on record
City records show the 2017 permit was finalized; the permit description states “REPAIR/ REPLACE 200AMP”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 65 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (16), addition / alteration (15), fire automatic extinguishing system (9) and floodplain use (5). 31 of them carry a final inspection; the other 34 were issued, expired or are still open, which is not the same as work completed. There are 30 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 115180220. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All institutional and public property · Commercial property in 85705 · Commercial & industrial reports · Homes in 85705 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N ORACLE RD hold 4,598 City permits on record, 1,059 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (95 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-COM-0626-00969Commercial Trade PermitIssued
2026CE-VIO0626-02705Code enforcement caseReferred
2026TC-COM-0526-00735Commercial Addition/Alteration PermitNeeds Resubmittal
2026TF-FCP-0226-00097Fire Automatic Extinguishing System PermitInspections
2026TF-FCP-0326-00163Fire Alarm System PermitIssued
2025TC-COM-0624-01123Commercial Addition/Alteration PermitNeeds Resubmittal
2025TD-DIV-1025-00097Subdivision/PlatsComplete
2025TZ-CMP-0925-00161Zoning ComplianceComplete
2025CE-VIO0825-03290FireClosed - Resolved
2025TC-DMO-0625-00114Commercial Demolition PermitApproved
2025TD-DIV-0425-00047Land Split/Lot SplitComplete
2024TD-DEV-0324-00070Development PackageFees Paid
2024TE-FPU-0924-00295Floodplain Use PermitIssued
2024CE-VIO0924-03640FireClosed - Resolved
2024CE-VIO0924-03639FireClosed - Resolved
2024CE-VIO0924-03638FireClosed - Resolved
2024CE-VIO0924-03637FireClosed - Resolved
2024CE-VIO0724-02712FireClosed - Resolved
2024CE-VIO0624-02507FireClosed - Resolved
2024TC-UTL-0324-00011Cell Tower Building PermitComplete
2024CE-VIO0624-02194FireClosed - Resolved
2024SD-0524-00047Historic Preservation Zone/Historic LandmarkComplete
2024CE-VIO0324-00858FireClosed - Resolved
2024TP-PRE-0224-00035Pre-Application ConferenceComplete
2023CE-VIO1223-07014FireClosed - Resolved
2023TP-PRE-1123-00369Pre-Application ConferenceComplete
2023CE-VIO0723-04599FireClosed - Resolved
2023CE-VIO0723-04597FireClosed - Resolved
2023recordROW Permit - City CIP/JOCFees Due
2023CE-VIO0123-01302FireClosed - Resolved
2022CE-VIO1022-00005FireClosed - Resolved
2022T22DV05239EMERGENCYCOMPLIAN
2022T22FC00526Fire Alarm System PermitComplete
2022T22DV03706EMERGENCYCOMPLIAN
2021T21CM06218Commercial Addition/Alteration PermitExpired
2021DP21-0268Development PackageIssued
2021T21OT00759Floodplain Use PermitIssued
2021T21FC00579Fire Alarm System PermitExpired
2021T21DV03048FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2021T21DV00275RESIDENTIAL ZONINGCOMPLIAN
2020T20DV07437EMERGENCYCOMPLIAN
2020T20CM07979Commercial Trade PermitApproved
2020T20DV06102EMERGENCYCOMPLIAN
2020T20DV00074RES: MINIMUM HOUSINGFIELD
2019T19OT01164Floodplain Use PermitSubmitted
2019T19CM09128Commercial Addition/Alteration PermitExpired
2018T18DV04018EMERGENCYCOMPLIAN
2017T17FC00781Fire Alarm System PermitExpired
2017T17FC00226Fire Automatic Extinguishing System PermitComplete
2017T17DV02894EMERGENCYNOVERIFY
2017T16CM07621Commercial Addition/Alteration PermitCanceled
2017T17FC00225Fire Automatic Extinguishing System PermitComplete
2017T17CM01532Commercial Trade PermitComplete
2017T17CM01462Commercial Addition/Alteration PermitWithdrawn
2015T15CM03065Commercial Trade PermitCanceled
2015T15CM02761Commercial Trade PermitWithdrawn
2015T15BU00447Fire Automatic Extinguishing System PermitCanceled
2015T14BU01403Fire Automatic Extinguishing System PermitComplete
2014T14CM02460Commercial Trade PermitCanceled
2014T14OT00531Floodplain Use PermitComplete
2014T14DV00395EMERGENCYNOVERIFY
2013T13CM06263Commercial Trade PermitCanceled
2011DP11-0011Development PackageComplete
2011T11DV03444RESIDENTIAL FIRECOMPLIAN
2011T11SA00098Zoning ComplianceComplete
2010T10DV02771EMERGENCYNOVERIFY
2010T09CM03268Commercial Trade PermitComplete
2009T09DV06874EMERGENCYCOMPLIAN
2009T09CM02328Commercial Addition/Alteration PermitComplete
2009T09OT01861Floodplain Use PermitCanceled
2009T09BU00427Commercial Trade PermitComplete
2008T08OT02951Permanent Sign PermitComplete
2008T08BU01820Commercial Addition/Alteration PermitCanceled
2008T08BU01826Fire Automatic Extinguishing System PermitComplete
2008T08CM03214Commercial Addition/Alteration PermitComplete
2008T08CM03149Commercial Addition/Alteration PermitCanceled
2008T08DV08517RES: MINIMUM HOUSINGREFERRED
2008T08DV01091ENVIRONMENTALREFERRED
2007T07EL01352Residential Trade PermitComplete
2006T06OT02643Peddler PermitCanceled
2003T03OT02236Commercial Addition/Alteration PermitComplete
2001T01EL01678Commercial Trade PermitComplete
2001T00CM05253Commercial Trade PermitCanceled
2001T01CM01876Commercial Trade PermitCanceled
2001T01BU00982Fire Automatic Extinguishing System PermitComplete
2000T00CM05537Commercial Addition/Alteration PermitComplete
2000T00BU03147Commercial Addition/Alteration PermitCanceled
2000T00EL00766Commercial Trade PermitCanceled
1999T99BU01949Commercial Addition/Alteration PermitComplete
1999T99ME00940Commercial Trade PermitComplete
1998T98BU01532Fire Automatic Extinguishing System PermitComplete
1998T98BU01284Commercial Trade PermitCanceled
1998T98BU01283Fire Automatic Extinguishing System PermitWithdrawn
1997T97CM02721Commercial Addition/Alteration PermitComplete
1997T97BU00814Commercial Pool/Spa PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 115180220 — 65 City permits on file from 1997 to 2026 and 30 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.