Electrical permit history — 542 W Flores St
542 W Flores St, Tucson — built 1975, with 5 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
542 W Flores St
Built 1975 — 1970s commercial stock · 5 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 542 W Flores St (aztucsonelectricalsolutions.com/property/11515086a/542-w-flores-st-tucson-az-85705) · Public records last checked 2026-08-16
- Parcel
- 11515086A
- Built
- 1975 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Auto Wrecking And/Or Salvage Yard
- Parcel size
- 0.59 acres
- Sewer
- Connection on file (1971) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 right-of-way (row) permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 right-of-way (row) permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2022. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
- Worth confirming
A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2003-03-31 | $115,000 | Warranty Deed |
| 1999-10-20 | $85,000 | Joint Tenancy Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2024-09-13 (TR-UTL-0924-01762) — Crew to perform maintenance work on small cell light poles, replacing existing radio with like for like.
Permit history (5)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-09-13finaled | TR-UTL-0924-01762City permit record | Right-of-Way (ROW) - UtilityCrew to perform maintenance work on small cell light poles, replacing existing radio with like for like | Complete | |
| 2024-06-19finaled | TR-ROW-0624-00709City permit record | Right-of-Way (ROW)323079 remove and replace 450LF of damaged 6" vcp that is leaking sewage from CO 5318*01 to MH 9218-03 | Complete | |
| 2024-06-18 | TR-ROW-0624-00704City permit record | Right-of-Way (ROW)323079 Site 1 - Remove and Replace 450LF of damaged 6" vcp sewer line from cleanout 5318*01 to mh 9218-03. | Void | |
| 2022-04-22finaled | T22CM03038City permit record | Electrical reconnectElectrical reconnect | Final | |
| 2020-03-12finaled | T20RW01625City permit record | Pool / spaPLACEMENT OF NEW CONDUIT/FIBER BY MEANS OF BORE 630' WITH (3) 1.25" ID, TRENCH 35' W/ (1) 4" CONDUIT, PL 3- 30" x 48" HH, PL AER CA & STRAND 3287' & PL 7 DOWN GUYS & ANCHORS, STARTING AT 538 W FLORES ST, E/O W FLORES ST, N/O 13TH AVE, STAY DIRECT N THRU THE ALLEY, E/O W ALTURAS ST, N/O N BALBOA AVE & END AT 2602 N BALBOA AVE ON PROJECT #Z3UFBPG132-TUC_TUC46_019. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 FOR COORDINATION. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2021-01-27 | T21DV00428Code enforcement case | Code enforcement case | Referred |
| 2008-10-28 | T08DV10198Code enforcement case | Vegetation | Noverify |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 11515086A — 5 permits on file from 2020 to 2024 (2 right-of-way (row), 1 right-of-way (row) - utility, 1 electrical reconnect, 1 pool / spa) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
