Electrical permit history — 234 W Plata St

234 W Plata St, Tucson — built 1998, with 16 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

234 W Plata St

Built 1998 — 1990s commercial stock · last permitted panel/service work 1998 (finaled)

Parcel
115061460
Built
1998 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Warehousing
Parcel size
1.38 acres
Building area
11,375 sq ft (assessor record)
Sewer
Connection on file (1998, 2008, 2011) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 1998 permit was finalized; the permit description states “UPGRADE:ELECTRIC:400AMP TO 600AMP” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 234 W Plata St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionGetting onLast permitted 1998 (28 years ago). Contractor of record: AFFORDABLE ELECTRIC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T98EL02165 — UPGRADE:ELECTRIC:400AMP TO 600AMP
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2007-06-29$1,250,000Warranty Deed
2006-01-20$900,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2020-10-19 (T20RW05717) — WORK ORDER: N.792285 - ALONG W. VENTURA ST. WEST OF N. STONE AVE FOLLOW ALLEYWAY SOUTH ALONG EXISTING POLES AND WEST RUNNING 1381' OF AERIAL CABLE PLACEMENT TO N. 10TH AVE. TRENCHING 16' AND PLACING NEW HANDHOLE #3048 INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS.

Permit history (16)

Permit history for this parcel — 8 of 16 records
DateRecordWhatStatusValue
2020-10-19finaledT20RW05717City permit recordROWWORK ORDER: N.792285 - ALONG W. VENTURA ST. WEST OF N. STONE AVE FOLLOW ALLEYWAY SOUTH ALONG EXISTING POLES AND WEST RUNNING 1381' OF AERIAL CABLE PLACEMENT TO N. 10TH AVE. TRENCHING 16' AND PLACING NEW HANDHOLE #3048 INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESSFinal
2011-04-08finaledT11PL00674City permit recordPLUMBREPLACE SEWER LINE; COMMFinal
2008-04-16finaledT08OT00904City permit recordSIGN14804Final
2008-02-05finaledT08OT00298City permit recordSIGN14445Final
2007-10-18finaledT07CM04107City permit recordCOMBOTI: WHOLESALES FLOORINGC of o
2006-07-25finaledT06OT01945City permit recordSIGN11544Final
2006-01-27finaledT06OT00237City permit recordSIGN10511Final
2006-01-19finaledT06OT00157City permit recordC-OF-OC OF OC of o
Show 8 older records
Permit history for this parcel — remaining 8 records
DateRecordWhatStatusValue
2005-11-16T05AN01224City permit recordADDRNEWIssued
2002-04-24finaledT02MH00142City permit recordMHMOBILE HOME:SETUPC of o
2001-03-14T01OT00076City permit recordSITESITE ONLYWithdrwn
1999-07-08finaledT99MH00389City permit recordMHMOBILE HOME:SETUPFinal
1999-07-08expired 2000-06-04T99MH00390City permit recordMHMOBILE HOME:SETUPExpired
1998-12-03finaledT98EL02165City permit recordELECTUPGRADE:ELECTRIC:400AMP TO 600AMPFinal
1997-07-14finaledT97BU01321City permit recordGRADINGGRADING: 200 CY CUT & 200CY FILLFinal
1997-04-23finaledT97CM00997City permit recordCOMBOWAREHOUSE:METAL BLDGC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (6)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 6 of 6 records
DateRecordWhatStatus
2022-05-13T22DV02942Code enforcement caseRefuseComplian
2010-06-29T10DV04235Code enforcement caseVegetationNoverify
2008-09-17T08DV08690Code enforcement caseCode enforcement caseCancel
2007-01-18finaledT07FR00159Code enforcement caseCode enforcement caseComplete
2006-12-12finaledT06FR02865Code enforcement caseCode enforcement caseComplete
2001-12-12T01VL03182Code enforcement caseElectricalComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 115061460 — 16 permits on file from 1997 to 2020 (4 sign, 3 mh, 2 combo, 1 row) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.