Electrical permit history — 8210 E Woodland Rd
8210 E Woodland Rd
- Electrical service: service or distribution work passed final inspection in 2016 (200 A per the permit).
- Watch for: built 1953; distribution gear this age is often past manufacturer support.
- Other work on record: trade permit 2016, addition or alteration permit 2014, development package permit 2012 (expired without a final), and 2 more — see the records below.
From City of Tucson permits and the Pima County Assessor, checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
Is it time to upgrade?
Probably not: the service was upgraded to 200 A in 2016.
- Electrical service & distributionLooks currentService or distribution work under a 2016 permit that passed final inspection (200 A per the permit). The nameplate on the service equipment is the final word. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T16CM02718 — 200 AMP SERVICE UPGRADE
- Heating, cooling & mechanicalWorth checkingNo permit on record names this system. Worth knowing: a 2014 addition / alteration permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyWorth checkingNo permit on record names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofWorth checkingNo permit on record names this system. The assessor records the roof as Built-Up Rock. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear.
- Worth confirming
There is an electrical reconnect permit from 2016. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
- Routine
A trade permit was pulled in 2003. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
Solar and energy potential
- Roof footprint
- ≈ 3,219 sq ft (county building-footprint layer, 2 structures; 1 neighbouring structure crossing the lot line excluded)
- Usable for solar, planning estimate
- ≈ 2,300 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 25 kW — roughly 60 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 41,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset at TEP commercial rates
- Estimate $3,500–$5,500 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)
The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Irvington and Houghton”, is about 5.2 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 11450005B ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 11450005B
- Year constructed
- 1953 (assessor record)
- Permitting authority
- Tucson
- Zoning
- SR
- Property type
- Store&Sfr 2/3/Fourplex Or Other Uses
- Building area
- 938 sq ft
- Cooling
- WARMED AND COOLED AIR
- Heating
- Forced Air
- Electrical service
- Service or distribution work under a 2016 permit that passed final inspection (200 A per the permit). The nameplate on the service equipment is the final word.
Building area, cooling and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.
What this means for work here
The most recent permit with evidence of issuance is dated 2016. City records show the permit was finalized. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 16 building permits for this parcel dated between 2001 and 2016. Six trade permits, five addition or alteration permits, two floodplain use permits and one zoning compliance permit. 5 of them carry a final inspection; the other 11 were issued, expired or are still open, which is not the same as work completed. There are 10 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (15): 2016 T16CM02718 · 2016 T16CM02218 · 2016 T16CM02157 · 2014 T14OT00192 · 2013 T13PRE0062 · 2012 DP12-0093 · 2009 T09CM00403 · 2009 T09OT00794 · 2008 T08EL02258 · 2008 T08CM00907 · 2003 T03CM02087 · 2003 T03OT00816 · 2003 T03PL00688 · 2003 T03PL00214 · 2001 T00BU03656
Code enforcement cases (10): 2015 T15DV03049 · 2014 T14DV00040 · 2013 T13DV08613 · 2013 T13DV01890 · 2012 T12DV07536 · 2012 T12DV02388 · 2011 T11DV03656 · 2011 T11DV01677 · 2010 T10DV05092 · 2008 T08DV00625
Variance (1): 2013 T13SA00279
Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11450005B.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All commercial property · Commercial property in 85749 · Commercial & industrial reports · Homes in 85749 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 8210 E Woodland Rd (aztucsonelectricalsolutions.com/property/11450005b/8210-e-woodland-rd-tucson-az-85749)
Electrical summary — 8210 E Woodland Rd, Tucson, AZ 85749
Parcel 11450005BYear built 1953Building area 938 sq ftPermit history City of TucsonRecord checked 13 Nov 2026
- Electrical service: service or distribution work passed final inspection in 2016 (200 A per the permit).
- Watch for: built 1953; distribution gear this age is often past manufacturer support.
- Other work on record: trade permit 2016, addition or alteration permit 2014, development package permit 2012 (expired without a final), and 2 more — see the records below.
Permits on record, newest first
| Date | Permit | Type | Status |
|---|---|---|---|
| Apr 2016 | T16CM02718 | Electrical service/panel | Final |
| Mar 2016 | T16CM02157 | Trade permit | Final |
| Apr 2014 | T14OT00192 | Addition or alteration permit | Final |
| Sep 2013 | T13SA00279 | Zoning compliance permit | Open |
| Jun 2012 | DP12-0093 | Development package permit | Expired (no final) |
| Apr 2003 | T03PL00688 | Trade permit | Final |
| Jan 2003 | T03PL00214 | Trade permit | Final |
Voided or withdrawn permit records: 9 (not listed).
Era flags
- Built 1953: distribution gear this age is often past manufacturer support.
Ask your inspector or engineer to check
- The main switchboard’s nameplate rating and the age and make of the distribution gear.
- Whether the arc-flash labels match the installed gear (NFPA 70E reviews them every five years).
Live report: https://www.aztucsonelectricalsolutions.com/property/11450005b/8210-e-woodland-rd-tucson-az-85749
How this property compares nearby
Properties on E WOODLAND RD hold 248 City permits on record, 69 of them since 2022.
Counts and years from the same public records.
Complete permit record (26 entries)
Every permit and case we hold for this parcel, newest first. Each number links to the official file.
| Year | Number | Type | Status |
|---|---|---|---|
| 2016 | T16CM02718 | Residential Trade Permit | Complete |
| 2016 | T16CM02218 | Residential Trade Permit | Canceled |
| 2016 | T16CM02157 | Residential Trade Permit | Complete |
| 2015 | T15DV03049 | SIGN VIOLATION | COMPLIAN |
| 2014 | T14OT00192 | Commercial Addition/Alteration Permit | Complete |
| 2014 | T14DV00040 | SIGN VIOLATION | COMPLIAN |
| 2013 | T13DV08613 | RESIDENTIAL ZONING | NOVERIFY |
| 2013 | T13SA00279 | Zoning Compliance | Effectuated |
| 2013 | T13PRE0062 | Pre-Application Conference | Canceled |
| 2013 | T13DV01890 | RESIDENTIAL ZONING | NOVERIFY |
| 2012 | T12DV07536 | MULTIPLE TYPES | COMPLIAN |
| 2012 | DP12-0093 | Development Package | Expired |
| 2012 | T12DV02388 | RESIDENTIAL ZONING | COURTCMP |
| 2011 | T11DV03656 | RESIDENTIAL ZONING | COMPLIAN |
| 2011 | T11DV01677 | RESIDENTIAL ZONING | NOVERIFY |
| 2010 | T10DV05092 | RESIDENTIAL ZONING | COMPLIAN |
| 2009 | T09CM00403 | Residential Addition/Alteration Permit | Canceled |
| 2009 | T09OT00794 | Floodplain Use Permit | Canceled |
| 2008 | T08EL02258 | Residential Trade Permit | Canceled |
| 2008 | T08CM00907 | Residential Addition/Alteration Permit | Withdrawn |
| 2008 | T08DV00625 | VACANT AND NEGLECTED PROGRAM | COMPLIAN |
| 2003 | T03CM02087 | Residential Addition/Alteration Permit | Canceled |
| 2003 | T03OT00816 | Floodplain Use Permit | Canceled |
| 2003 | T03PL00688 | Residential Trade Permit | Complete |
| 2003 | T03PL00214 | Residential Trade Permit | Complete |
| 2001 | T00BU03656 | Residential Addition/Alteration Permit | Withdrawn |
How this report was built
This is a reading of public records for parcel 11450005B — 16 City permits on file from 2001 to 2016 and 10 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The construction year, living area, cooling, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 13 Nov 2026 from the City’s permit export of that day.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.