Electrical permit history — 2464 N Pantano Rd
2464 N Pantano Rd, Tucson — built 1974, with 49 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
2464 N Pantano Rd
Built 1974 — 1970s commercial stock · HVAC 1999 (finaled)
Permanent link: Electrical permit history for 2464 N Pantano Rd (aztucsonelectricalsolutions.com/property/11449042n/2464-n-pantano-rd-tucson-az-85715) · Public records last checked 2026-08-16
- Parcel
- 11449042N
- Built
- 1974 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Retail Strip Center
- Parcel size
- 0.96 acres
- Building area
- 11,236 sq ft (assessor record)
- Sewer
- Connection on file (1984) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2003 addition / alteration permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalLikely dueLast permitted 1999 (27 years ago). Contractor of record: TANQUE VERDE AIR CONDITIONING ,. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T99ME00026 — AIR COND:FURNACE:REPLACEMENT
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2004-09-10 | $2,203,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2022-08-05 (T22CM05987) — THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASEDAND TOWER MOUNTED EQUIPMENT AS INDICATED PER BE.
Permit history (49)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-08-05expired 2024-01-15 | T22CM05987City permit record | Commercial BuildingTHE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASEDAND TOWER MOUNTED EQUIPMENT AS INDICATED PER BE | Issued | |
| 2020-12-05expired 2021-07-24 | T20CM08537City permit record | Commercial BuildingModification to existing wireless communication facility | Expired | |
| 2018-01-26finaled | T18CM00667City permit record | COMBOSPRINT NEW ANTENNA INSTALL | Final | |
| 2017-12-22expired 2018-06-20 | T17OT01310City permit record | Fence / wallC OF C ON ILLUM WALL SIGN. | Expired | |
| 2016-11-17expired 2017-10-02 | T16CM08674City permit record | COMBOGENERATOR WITH A 210GAL. FUEL TANK- VERIZON | Expired | |
| 2016-09-09finaled | T16RW01464City permit record | ROWSTARTING AT EXISTING COX PED, PULLING THRU EXISTING CONDUIT 125' EAST THEN TURN AND HEAD SOUTH AND CONTINUE TO PULL 629' EAST IN EXISTING PIPE DOWN EAST WRIGHTSTOWN RD THEN TURN AND HEAD NORTH ONTO PROPERTY. WORK ORDER # 41520160000CTU0429 | Final | |
| 2016-08-04finaled | T16RW00914City permit record | ROWSTARTING ON THE N SIDE OF E WRIGHTSTOWN RD JUST W OF N PANTANO RD AT COX PED PULL THRU EXISTING 2" CONDUIT HEADING E FOR 669' THEN N FOR 337' OUT OF ROW WORK ORDER # 41520160000CTU0293 | Final | |
| 2016-07-07finaled | T16RW00347City permit record | ROWSTARTING AT THE COX PEDESTAL AT THE NW COR OF WRIGHTSTOWN RD AND PANTANO RD, PULL THROUGH EXISTING 2" CONDUIT HEADING E FOR 629', THEN N 424', THEN W 120' TO OUT OF ROW | Final |
41 older records are not shown here. — each links to its official file.
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (4)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2022-11-01 | CE-VIO1122-00046Code enforcement case | Code enforcement case | Closed - resolved |
| 2014-07-16 | T14DV04883Code enforcement case | Code enforcement case | Complian |
| 2011-09-16 | T11DV07435Code enforcement case | Work without permit | Complian |
| 2006-04-28finaled | T06FR01072Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 11449042N — 49 permits on file from 1998 to 2022 (13 combo, 9 sign, 9 c-of-o, 6 mech) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.