Electrical permit history — 7871 E Wrightstown Rd
7871 E Wrightstown Rd, Tucson — built 1973, with 22 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
7871 E Wrightstown Rd
Built 1973 — 1970s commercial stock · last permitted panel/service work 2023 (permitted, completion not confirmed)
Permanent link: Electrical permit history for 7871 E Wrightstown Rd (aztucsonelectricalsolutions.com/property/114462090/7871-e-wrightstown-rd-tucson-az-85715) · Public records last checked 2026-08-16
- Parcel
- 114462090
- Built
- 1973 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Office Building 1 Story
- Parcel size
- 0.82 acres
- Building area
- 2,340 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- A 2023 permit was issued; completion is not confirmed in the available record; the permit description states “T21CM01721 was closed before the electrical portion could be completed. Dish will be installing new 200 amp panel, meter and disconnect per E-1 - E-3 of the attached CD's. Electrical inspection will be required.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “T21CM01721 was closed before the electrical portion could be completed. Dish will be installing new 200 amp panel, meter and disconnect per E-1 - E-3 of the attached CD's. Electrical inspection will be required.”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. City inspection record: COT - LCEL - Electrical Final approved 2023-04-04. TC-COM-0223-00720 — T21CM01721 was closed before the electrical portion could be completed. Dish will be installing new 200 amp panel, meter and disconnect per E-1 - E-3 of the attached CD's. Electrical inspection will be required.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2008-10-31 | $1,100,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2024-12-04 (TC-UTL-1224-00105) — remove and replace existing antennas and ancillary equipment on existing cell tower.
Permit history (22)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-12-04finaled | TC-UTL-1224-00105City permit record | Utilitiesremove and replace existing antennas and ancillary equipment on existing cell tower | Inspections complete | |
| 2023-02-27expired 2023-10-01 | TC-COM-0223-00720City permit record | Commercial BuildingT21CM01721 was closed before the electrical portion could be completed. Dish will be installing new 200 amp panel, meter and disconnect per E-1 - E-3 of the attached CD's. Electrical inspection will be required. | Issued | |
| 2022-06-27expired 2024-08-20 | T22CM04857City permit record | Commercial Buildingreplace antennas, ancillary equipment and ground equipment as per plansfor an existing carrier on a | Issued | |
| 2022-03-09expired 2023-07-05 | T22CM01721City permit record | Commercial BuildingCollocation of antennas, ancillary equipment, and ground equipment of a new carrier (Dish Wireless) | Issued | |
| 2021-03-12expired 2021-10-18 | T21CM02256City permit record | Commercial BuildingFees due before withdrawal can be processed. TENANT IMPROVEMENTS FOR OFFICES, ADD TWO WAREHOUSE BUILDINGS | Fees due | |
| 2021-03-12expired 2022-02-09 | T21CM02284City permit record | Commercial BuildingTENANT IMPROVEMENTS FOR OFFICES, ADD TWO WAREHOUSE BUILDINGS | Expired | |
| 2021-03-12expired 2022-02-09 | T21CM02285City permit record | Commercial BuildingFees due before withdrawal can be processed. TENANT IMPROVEMENTS FOR OFFICES, ADD TWO WAREHOUSE BUILDINGS | Fees due | |
| 2021-03-08expired 2022-01-31 | DP21-0062City permit record | Development Package*WITHDRAWN* Per customer's request // SITE - Citywide Restoration, new private RV and new storage. | Withdrawn |
Show 14 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2020-10-26finaled | T20BU00492City permit record | DemolitionDEMOLITION OF BUILDINGS #2 AND #3 | Final | |
| 2020-10-06finaled | T20RW05440City permit record | ROWStarting in front of 7831 E WRIGHTSTOWN RD at Cox existing Ped, trench/bore West 25' to out of row | Final | |
| 2020-09-22expired 2021-10-06 | T20CM06566City permit record | Commercial BuildingINSTALL 400 AMP PANEL | Expired | |
| 2017-02-03finaled | T17CM00910City permit record | COMBOCELL TOWER TO REMOVE AND REPLACE | Final | |
| 2012-04-19finaled | T12CM02066City permit record | COMBOREMOVE:INSTALL:ANTENNAS | Final | |
| 2011-03-14finaled | T11CM00767City permit record | COMBOADD 2 ANTENNAS, REPLACE RADIO CABINETS | Final | |
| 2010-02-11expired 2011-03-24 | T10CM00316City permit record | COMBOCOLLOCATION ON EXISTING MONOPOLE CELL SITE | Expired | |
| 2009-12-28completed 2009-12-28 | T09SE00070Special exception | Zoning Examiner Special ExceptionSE-09-70 Clearwire-Wrightstown - A request to allow a co-location on an existing 100-foot-high tower with associated ground equipment on a .73-acre site.SE-09-70 Clearwire-Wrightstown | Approved | |
| 2008-12-05finaled | T08OT02851City permit record | SIGN16002 | Final | |
| 2008-11-17finaled | T08OT02702City permit record | SIGN15912 | Final | |
| 2008-11-14expired 2009-05-13 | T08OT02685City permit record | SIGN15900 | Expired | |
| 2004-11-10finaled | T04CM04966City permit record | COMBOCO LOCATE MICROWAVE DISH ANTENNA | Final | |
| 2002-07-02finaled | T02CM03153City permit record | COMBOANTENNA:WIRELESS | Final | |
| 2000-09-08expired 2001-05-30 | T00CM04488City permit record | COMBOCELLULAR SITE | Closed |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (11)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2022-04-21 | T22DV02579Code enforcement case | Code enforcement case | Complian |
| 2021-11-17 | T21DV08227Housing code violation | PROP MAINT MULTIPLE TYPESrecorded before 2023 | NOVERIFY |
| 2021-09-20 | T21DV06572Code enforcement case | Graffiti | Noverify |
| 2017-03-10 | T17DV00993Code enforcement case | Vegetation | Complian |
| 2014-01-31 | T14DV00595Code enforcement case | Vegetation | Complian |
| 2013-07-22 | T13DV05272Code enforcement case | Vegetation | Complian |
| 2010-03-01 | T10DV00943Code enforcement case | Sign | Noverify |
| 2010-01-08 | T10DV00100Code enforcement case | Code enforcement case | Complian |
Show 3 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2009-06-05 | T09DV03166Code enforcement case | Code enforcement case | Noverify |
| 2007-08-29 | T07DV08586Code enforcement case | Sign | Complian |
| 2001-03-15 | T01VL00748Code enforcement case | Sign | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 114462090 — 22 permits on file from 2000 to 2024 (7 commercial building, 7 combo, 3 sign, 1 utilities) and 11 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.