Electrical permit history — 1545 E Copper St

1545 E Copper St, Tucson — built 1950, with 118 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

1545 E Copper St

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1950 — 1950s commercial stock · last permitted panel/service work 2024 (finaled) · HVAC 2020 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2024 (2 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. Installing New 6" Fire Protection Service
  • Heating, cooling & mechanicalFinaled permit foundLast permitted 2020 (6 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T20CM00686 — E - TI BATHROOMS; REPLACE HVAC
  • Fire alarm & life safetyFinaled permit foundA newer 2025 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “EXPEDITE - Cellular monitoring”. Last permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0624-00486 — New building. Adding fire alarm to existing system.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2024 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2015. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Worth confirming

    A pool or spa was permitted in 2000. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2018. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 208,584 sq ft (county building-footprint layer, 9 structures)
Usable for solar, planning estimate
≈ 146,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 1,610 kW — roughly 4,030 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 2,650,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$212,000–$345,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 2.7 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11310001A
Year constructed
1950 (assessor record)
Permitting authority
Tucson
Zoning
PAD-17
Property type
Misc Commercial
Building area
255,839 sq ft
Service on record
City records show the 2024 permit was finalized; the permit description states “Installing New 6" Fire Protection Service”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 118 building permits for this parcel dated between 1997 and 2026. By category the work is addition / alteration (31), trade permit (17), fire alarm system (9) and development package (9). 94 of them carry a final inspection; the other 24 were issued, expired or are still open, which is not the same as work completed. There are 5 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11310001A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85719 · Commercial & industrial reports · Homes in 85719 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E COPPER ST hold 548 City permits on record, 110 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (123 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TP-PRE-0226-00044Pre-Application ConferenceComplete
2025recordROW Permit - Street BannersComplete
2025TF-FCP-0825-00642Fire Alarm System PermitExpired
2025TC-COM-0825-01453Commercial Addition/Alteration PermitExpired
2025recordRight-of-Way (ROW) Permit - UtilityNeeds Resubmittal
2025TF-FOP-0125-00023Special Events Fire Permit - VendorComplete
2024TC-CFO-1224-00250Temporary Certificate-of-Occupancy (TCO)Complete
2024TC-CFO-1224-00248Temporary Certificate-of-Occupancy (TCO)Denied
2024TC-COM-0824-01657Commercial Addition/Alteration PermitIssued
2024TC-COM-1124-02197Commercial Addition/Alteration PermitExpired
2024TF-FOP-0324-00336General Operational Fire PermitComplete
2024TF-FOP-0324-00335General Operational Fire PermitComplete
2024TF-FOP-1024-01225Special Events Fire Permit - OrganizerComplete
2024recordROW Permit - Development/BuildingComplete
2024recordROW Permit - Development/BuildingComplete
2024TF-FCP-0624-00486Fire Alarm System PermitComplete
2024TF-FCP-0424-00334Fire Automatic Extinguishing System PermitComplete
2024TF-FCP-0424-00311Fire Automatic Extinguishing System PermitComplete
2024recordRight-of-Way (ROW) Permit - GeneralComplete
2024recordRight-of-Way (ROW) Permit - UtilityComplete
2023TC-COM-0223-00705Commercial New Building PermitComplete
2023TC-DMO-0123-00040Commercial Demolition PermitComplete
2023recordRight-of-Way (ROW) Permit - GeneralComplete
2023recordRight-of-Way (ROW) Permit - UtilityComplete
2023recordRight-of-Way (ROW) Permit - GeneralComplete
2023TF-FOP-0823-01404Special Events Fire Permit - OrganizerComplete
2023TF-FCP-0823-00918Fire Alarm System PermitComplete
2023TD-DEV-0223-00150Development PackageNeeds Resubmittal
2023TD-DEV-0223-00126Development PackageComplete
2023TF-FOP-0123-00368Special Events Fire Permit - OrganizerComplete
2022T22FC00692Fire Alarm System PermitComplete
2022T22FO00799Special Events Fire Permit - OrganizerComplete
2022T22CM05683Commercial Addition/Alteration PermitIssued
2022T22DV04032EMERGENCYCOMPLIAN
2022T22CM03542Commercial Addition/Alteration PermitIssued
2021T21FO00434Special Events Fire Permit - OrganizerComplete
2021T21DV01816FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2021T21CM01063Commercial Trade PermitExpired
2020T20DV07516OBSTR DEAD TREES AND SHRUBSREFERRED
2020T20CM00686Commercial Addition/Alteration PermitComplete
2019T19FC00845Fire Alarm System PermitComplete
2019T19FC00812Fire Automatic Extinguishing System PermitComplete
2019T19FO00760Special Events Fire Permit - OrganizerComplete
2019T19FC00591Fire Alarm System PermitComplete
2019T19FC00598Fire Alarm System PermitComplete
2019T19FC00582Fire Automatic Extinguishing System PermitComplete
2019DP12-0040Development PackageComplete
2019T19CM03187Commercial Addition/Alteration PermitComplete
2019T19FO00364Special Events Fire Permit - VendorComplete
2019T19CM01881Commercial Addition/Alteration PermitComplete
2019T19CM00711Commercial Addition/Alteration PermitComplete
2019T18CM09798Commercial Addition/Alteration PermitComplete
2019T18CM09799Commercial Addition/Alteration PermitComplete
2019DP18-0282Development PackageComplete
2018T18BU00516Commercial DemolitionComplete
2018T18CM05621Commercial Trade PermitComplete
2018T18CM03794Commercial Trade PermitComplete
2017T17SE00183Mayor Council Special ExceptionApproved
2017T17DV05820OBSTR DEAD TREES AND SHRUBSNOVERIFY
2017T17DV03226REFUSENOVERIFY
2016T16FC00140Fire Alarm System PermitComplete
2016T16FC00065Fire Alarm System PermitComplete
2016T16BU01049Commercial Trade PermitComplete
2016T16BU00852Commercial Trade PermitComplete
2016T16CM01968Commercial Addition/Alteration PermitComplete
2015T15SE00073Mayor Council Special ExceptionApproved
2015T15BU00466Commercial Trade PermitComplete
2015T15CM01793Commercial Addition/Alteration PermitComplete
2015T14CM08854Residential Solar PermitComplete
2014T14CM07226Commercial Addition/Alteration PermitCanceled
2014T14CM03845Commercial Addition/Alteration PermitCanceled
2014T14BU00696Commercial Trade PermitComplete
2014T14BU00551Commercial Fence/Wall PermitComplete
2014T14BU00398Fire Automatic Extinguishing System PermitComplete
2014T14CM00885Commercial Addition/Alteration PermitComplete
2014DP14-0014Development PackageComplete
2014T14BU00250Commercial Trade PermitComplete
2014T14BU00029Fire Automatic Extinguishing System PermitComplete
2014T13BU01363Commercial New Building PermitComplete
2013T13CM04494Commercial New Building PermitComplete
2013DP13-0131Development PackageComplete
2013T13BU01182Fire Automatic Extinguishing System PermitComplete
2013T13CM03807Residential Solar PermitCanceled
2013DP13-0117Development PackageExpired
2013T13BU00650Commercial Trade PermitComplete
2013T13CM01691Commercial Addition/Alteration PermitCanceled
2013T13BU00450Commercial Trade PermitComplete
2013T12CM08238Commercial Addition/Alteration PermitComplete
2012T12CM03226Commercial New Building PermitComplete
2012T12CM03902Commercial Addition/Alteration PermitCanceled
2012DP12-0088Development PackageComplete
2012T12BU00703Commercial Trade PermitComplete
2012T12CM01256Commercial Addition/Alteration PermitCanceled
2012T12CM00676Commercial Addition/Alteration PermitComplete
2011T10CM03545Commercial Addition/Alteration PermitComplete
2011T10CM03308Residential Solar PermitComplete
2011T10OT02539Floodplain Use PermitComplete
2010T10EL01476Commercial Trade PermitComplete
2010T10CM00665Commercial Addition/Alteration PermitComplete
2010T10OT00789Floodplain Use PermitComplete
2009T09BU00503GradingCanceled
2008C9-08-16 RezoningEffectuated
2008T08BU01363Commercial Addition/Alteration PermitComplete
2007T07PRE0078Pre-Application ConferenceCanceled
2007T07BU01695Commercial Addition/Alteration PermitComplete
2007T07CM01333Commercial Addition/Alteration PermitComplete
2006T06CM01058Commercial Addition/Alteration PermitComplete
2005T05BU02695Commercial Trade PermitComplete
2005T05CM03302Commercial Addition/Alteration PermitComplete
2004T04BU02592Commercial Trade PermitComplete
2004T04BU01812Commercial Fence/Wall PermitCanceled
2004T04CM02391Commercial Addition/Alteration PermitComplete
2003T03BU01962Commercial Trade PermitComplete
2003T03CM00888Commercial Addition/Alteration PermitComplete
2001T01EL01930Commercial Trade PermitComplete
2000T00BU03624Residential Fence/Wall PermitComplete
2000T00BU02842Residential Pool/Spa PermitComplete
2000T00CM00590Commercial Addition/Alteration PermitComplete
2000T00ME00177Commercial Trade PermitComplete
1999T99BU02698Fire Automatic Extinguishing System PermitComplete
1999T99OT00223Development PackageWithdrawn
1997T97BU00646Commercial DemolitionComplete
1997T97CM00327Commercial New Building PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11310001A — 118 City permits on file from 1997 to 2026 and 5 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.