Electrical permit history — 1125 E Glenn St

1125 E Glenn St, Tucson — built 1965, with 22 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1125 E Glenn St

Built 1965 — 1960s commercial stock · last permitted panel/service work 2005 (permit expired without a confirmed final)

Parcel
113080760
Built
1965 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Day Care/Pre-School Ctr Private Children
Parcel size
0.92 acres
Building area
3,863 sq ft (assessor record)
Sewer
Connection on file (1961, 1977, 2009) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2005 permit expired without a confirmed final status; the permit description states “UPGRADE:100-200 AMP (APA)” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 1125 E Glenn St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2005 permit specifies this work (the permit description states “UPGRADE:100-200 AMP (APA)”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T05EL01356 — UPGRADE:100-200 AMP (APA)
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00673 — INSTALL ONE (1) DMP LTE DUALCOM FIRE RADIO
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2013-05-02$1,011,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-05-13 (TC-COM-0526-00699) — REMOVAL OF AN EXISTING BEARING WALL. INSTALLATION OF A NEW SUPPORT BEAM. ADD NEW EXTERIOR DOOR - CREATING AN OFFICE WITH NEW DOOR AND 2 NEW WINDOWS. NO EXPANSION.

Permit history (22)

Permit history for this parcel — 8 of 22 records
DateRecordWhatStatusValue
2026-05-13TC-COM-0526-00699City permit recordFence / wallREMOVAL OF AN EXISTING BEARING WALL. INSTALLATION OF A NEW SUPPORT BEAM. ADD NEW EXTERIOR DOOR - CREATING AN OFFICE WITH NEW DOOR AND 2 NEW WINDOWS. NO EXPANSIONIn review
2026-02-19finaledTF-FOP-0226-00265City permit recordFire OperationalLicensed childcare centerComplete
2025-02-05finaledTF-FOP-0225-00175City permit recordFire OperationalLittle Ranch School Licensed childcare centerComplete
2024-01-30finaledTF-FOP-0124-00130City permit recordFire OperationalAnnual PermitComplete
2022-10-13finaledT22FO00898City permit recordFIREOPER187 PEOPLEFinal
2021-10-19finaledT21FO00713City permit recordFIREOPER187 PERSONSFinal
2020-10-14finaledT20FC00673City permit recordFIRECONSINSTALL ONE (1) DMP LTE DUALCOM FIRE RADIOFinal
2020-09-24finaledT20FO00484City permit recordFIREOPERLITTLE RANCH PRESCHOOL OCC LOAD:187Final
Show 14 older records
Permit history for this parcel — remaining 14 records
DateRecordWhatStatusValue
2019-07-16finaledT19FO00553City permit recordFIREOPERLITTLE RANCH SCHOOL - Occ: 185Final
2018-08-06finaledT18FO00628City permit recordFIREOPERPreschool - OCC Load 182Final
2017-09-20expired 2018-05-12T17FO00783City permit recordFIREOPERCHILD CAREVoid
2017-09-15T17FO00775City permit recordFIREOPERPRESCHOOL 182Void
2017-05-23finaledT17FO00450City permit recordFIREOPERCHILD CAREFinal
2013-03-26finaledT13BU00351City permit recordBUILDINSTALL NEW FIRE ALARM SYSTEM FOR NEW PORTABLE BUILDINGFinal
2012-04-24finaledT12CM02188City permit recordCOMBOTI: CHILD CARE FACILITYC of o
2009-10-20finaledT09CM02805City permit recordCOMBOTI: PRESCHOOLFinal
2009-05-20finaledT09OT01013City permit recordC-OF-OC OF O: DAY CAREC of o
2009-05-20finaledT09OT01014City permit recordC-OF-OC OF O: DAY CAREC of o
2009-05-20finaledT09OT01015City permit recordC-OF-OC OF O: DAY CAREC of o
2009-05-20finaledT09OT01016City permit recordC-OF-OC OF O: LEARNING CENTERC of o
2009-05-19T09AN00292City permit recordADDRNEWIssued
2005-07-05expired 2006-01-01T05EL01356City permit recordELECTUPGRADE:100-200 AMP (APA)Expired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (5)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 5 of 5 records
DateRecordWhatStatus
2009-12-15finaledT09FR03773Code enforcement caseFireComplete
2009-03-30T09DV01528Code enforcement caseCode enforcement caseComplian
2008-09-30T08FR03275Code enforcement caseCode enforcement caseField
2006-12-22finaledT06FR02925Code enforcement caseCode enforcement caseComplete
1999-04-05T99VL00915Code enforcement caseWork without permitComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 113080760 — 22 permits on file from 2005 to 2026 (8 fireoper, 4 c-of-o, 3 fire operational, 2 combo) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.