Electrical permit history — 1533 E Blacklidge Dr
1533 E Blacklidge Dr, Tucson — built 1959, with 18 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
1533 E Blacklidge Dr
Built 1959 — 1950s multifamily stock · last permitted panel/service work 2014 (finaled) · HVAC 2006 (permit expired without a confirmed final)
Permanent link: Electrical permit history for 1533 E Blacklidge Dr (aztucsonelectricalsolutions.com/property/113071950/1533-e-blacklidge-dr-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 113071950
- Built
- 1959 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-2
- Assessor use
- Apartments 5 - 24 Units 1 Story
- Parcel size
- 0.82 acres
- Building area
- 8,400 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2014 permit was finalized; the permit description states “ELECTRIC UPGRADE UP TO 200 AMP (4PLEX)” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2014 (12 years ago). City inspection record: ELECTRIC - FINAL approved 2015-12-04. Contractor of record: 2 ZONA ELECTRICAL SERVICES INC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T14CM05143 — ELECTRIC UPGRADE UP TO 200 AMP (4PLEX)
- Heating, cooling & mechanicalPermitted — completion not confirmedA 2006 permit specifies this work (the permit description states “Gas System Replacement: 1" pipe from meter to house to feed existing furnace, water heater and stove.”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. City inspection record: last recorded inspection 2006-11-07; no approved final is shown. Contractor of record: PLUMB PLUMBING LLC. T06PL02015 — Gas System Replacement: 1" pipe from meter to house to feed existing furnace, water heater and stove.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (5)
| Date | Price | Type |
|---|---|---|
| 2025-04-21 | $3,420,000 | Warranty Deed |
| 2012-12-14 | $569,000 | Warranty Deed |
| 2010-03-10 | $460,000 | Warranty Deed |
| 2006-01-03 | $725,000 | Warranty Deed |
| 2005-07-25 | $700,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2021-04-08 (T21RW01653) — (2) 5X5 bell holes in blktp front-- to repair/replace gas line ISSAP NPL *CREWS WILL ALSO BE WORKING AT 1515&1519 E BLACKLIDGE DR Proof of notification is required at the time of the preconstruction meeting..
Permit history (18)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2021-04-08finaled | T21RW01653City permit record | ROW(2) 5X5 bell holes in blktp front-- to repair/replace gas line ISSAP NPL *CREWS WILL ALSO BE WORKING AT 1515&1519 E BLACKLIDGE DR Proof of notification is required at the time of the preconstruction meeting. | Final | |
| 2020-06-02finaled | T20RW03145City permit record | ROWProvide new 211 Concrete Collar & Bench Rehab on MH 9781-02. Excavate 72 LF to repair broken pipe. Install a total of 364 LF of CIPP, a trench-less technology that will not disturb the surface of the earth. NOTES: ***CONTRACTER MUST NOTIFY RESIDENTS 48 HOURS IN ADVANCE*** | Final | |
| 2014-10-21finaled | T14CM07076City permit record | COMBOREPLACE GAS LINE TO RES | Final | |
| 2014-08-08finaled | T14CM05143City permit record | COMBOELECTRIC UPGRADE UP TO 200 AMP (4PLEX) | Final | |
| 2014-06-20finaled | T14CM03825City permit record | COMBOREPLACEMENT - BREAKER | Final | |
| 2013-04-12finaled | T13CM02185City permit record | COMBOUPGRADE ELECTRIC FROM 60 - 100 AMPS - DUPLX | Final | |
| 2013-03-22finaled | T13CM01658City permit record | COMBOUPGRADE ELECTRIC 100 AMPS- DUPLEX | Final | |
| 2013-02-08finaled | T13CM00760City permit record | COMBOUPGRADE ELECTRIC 100 AMPS | Final |
Show 10 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2010-05-11expired 2010-11-07 | T10EL01106City permit record | ELECTUPGRADE OVERHEAD ELECTRICAL RISER | Closed | |
| 2010-05-11finaled | T10EL01107City permit record | ELECTUPGRADE OVERHEAD ELECTRICAL RISER R-1 NEW ELECTRIC METERS (3) | Final | |
| 2010-05-11expired 2010-11-07 | T10EL01108City permit record | ELECTUPGRADE OVERHEAD ELECTRICAL RISER | Expired | |
| 2006-11-06 | T06PL02014City permit record | PLUMBReplacement gas system w/1" pipe to feed existing furnace, water heater and stove. | Withdrwn | |
| 2006-11-06expired 2007-05-06 | T06PL02015City permit record | PLUMBGas System Replacement: 1" pipe from meter to house to feed existing furnace, water heater and stove. | Expired | |
| 2006-01-18expired 2006-03-19 | T06EX00073City permit record | EXCAVSTREET CUT FOR SEWER LINE | Closed | |
| 2005-01-20finaled | T05PL00126City permit record | PLUMBREPLACE:WATER HEATER (APA) | Final | |
| 2005-01-13finaled | T05PL00080City permit record | PLUMBREPLACE:GAS LINE APA | Final | |
| 2003-08-13finaled | T03PL01326City permit record | PLUMBREPLACE:GAS LINE | Final | |
| 2001-12-26finaled | T01PL02621City permit record | PLUMBGAS LINE:REPLACE/RELOCATE | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (5)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2020-02-03 | T20DV00803Code enforcement case | Code enforcement case | Complian |
| 2016-01-06 | T16DV00062Code enforcement case | Code enforcement case | Complian |
| 2015-05-02 | T15DV03329Code enforcement case | Electrical | Complian |
| 2013-02-25 | T13DV01083Code enforcement case | Code enforcement case | Noverify |
| 2006-02-13 | T06VL00235Code enforcement case | Work without permit | Referred |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 113071950 — 18 permits on file from 2001 to 2021 (6 combo, 6 plumb, 3 elect, 2 row) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.