Electrical permit history — 2885 N Campbell Av

2885 N Campbell Av, Tucson — built 1973, with 18 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2885 N Campbell Av

Built 1973 — 1970s commercial stock · HVAC 2025 (permitted, completion not confirmed)

Parcel
113070010
Built
1973 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Bank
Parcel size
0.83 acres
Building area
5,851 sq ft (assessor record)
Sewer
Connection on file (1973) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 2885 N Campbell Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 row permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2025 permit specifies this work (the permit description states “To Replace 3 Rooftop AC Units and 1 Mini split”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Inspections. City inspection record: COT - LCME - Mechanical Final approved 2025-12-19. TC-COM-1025-01939 — To Replace 3 Rooftop AC Units and 1 Mini split
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-01-21 (TR-UTL-0126-00137) — T167193 - TEP remove 1 pole from ROW 2’X2’ 6’ deep hole with no sidewalk impact.

Permit history (18)

Permit history for this parcel — 8 of 18 records
DateRecordWhatStatusValue
2026-01-21finaledTR-UTL-0126-00137City permit recordRight-of-Way (ROW) - UtilityT167193 - TEP remove 1 pole from ROW 2’X2’ 6’ deep hole with no sidewalk impactComplete
2025-10-20expired 2026-06-17TC-COM-1025-01939City permit recordCommercial BuildingTo Replace 3 Rooftop AC Units and 1 Mini splitInspections
2025-10-10finaledTR-UTL-1025-01770City permit recordRight-of-Way (ROW) - UtilityCox to remove and overlash 140' of aerial strand and place (1) new ped and proof and pull through 410' of existing conduit and system tie. Fiber pull to be completed after conduit has been placed.Complete
2023-02-14finaledTR-UTL-0223-00864City permit recordRight-of-Way (ROW) - UtilityPRJ231322-7 Previous permit T22RW03386 that has expired. From TEP Pole Near 2885 N Campbell Ave, begin 492' aerial overlash 48 ct fiber. Tie in.Complete
2022-09-17finaledT22RW03386City permit recordRight-of-Way (ROW)60 DAYS - From TEP Pole Near 2855 N Campbell Ave, begin 492' aerial overlash 48 ct fiber. Tie in.Complete
2022-08-16finaledT22OT00586City permit recordSign - Permanent1- new df monuComplete
2022-04-26finaledT22OT00302City permit recordFence / wallwall signage - rebranding Bank of AmericaComplete
2021-05-03finaledT21RW02126City permit recordROWN.830159-1- ALONG N. CAMPBELL AVE PLACE 1036' AERIAL CABLE. CUT AND RESTORE 32' OF CONCRETE. ACCESS HH 19702 TO SPLICE NEW CABLE IN EXISTING HANDHOLES. PLACE 3 ARCHORS/DOWNGUYS. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. AND MUST BE A MINIMUM OF 18-FT HIGH WHEN CROSSING INTERSECTIONS, PAVEMENT AND ALLEYS. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESSFinal
Show 10 older records
Permit history for this parcel — remaining 10 records
DateRecordWhatStatusValue
2020-07-23finaledT20RW04250City permit recordROWWill be performing aerial maintenance on pole.Final
2020-01-03finaledT20RW00035City permit recordROWFormer Permit T19RW03475- requested per City inspector to repair 2 sidewalk panels ( 2885 N Campbell Ave).Final
2019-11-05T19CM08193City permit recordCommercial BuildingE - ADD 2 NEW LIGHT POLES AND CHANGE OUT EXISTING FIXTURESExpired
2019-06-17finaledT19RW03475City permit recordROWFrom the TEP pole on the south side of Adelaide Dr, riser down and begin 71' trench/bore heading East, continue 15' trench/bore, placing new COX ped. Continue 10' trench/bore to out of ROWFinal
2019-04-16finaledT19RW02067City permit recordROW1859ft of aerial placement, 72ft of boring, 25 SF of concrete removal and replacement. Placing (1) new 3048 HH.Final
2019-03-28finaledDP19-0076City permit recordDevelopment PackageSITE - Bank of America, maintenance, remove and replace in-kind existing hardscape.Complete
2019-03-28expired 2020-01-20T19CM02181City permit recordCOMBOTI:BANKExpired
2002-01-07finaledT02EL00034City permit recordELECTREPLACE:PARKING LIGHTINGFinal
1999-08-23expired 1999-10-22T99EX00973City permit recordEXCAVEXCAV:35LF OF SIDEWALKClosed
1999-06-11expired 2000-05-22T99EL01338City permit recordELECTSIGNS:CIRCUIT:9906051Expired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (3)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 3 of 3 records
DateRecordWhatStatus
2011-07-28T11DV06001Code enforcement caseVegetationNoverify
2010-04-27finaledT10FR00813Code enforcement caseCode enforcement caseComplete
2009-03-10finaledT09FR00865Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 113070010 — 18 permits on file from 1999 to 2026 (5 row, 3 right-of-way (row) - utility, 2 commercial building, 2 elect) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.