- Parcel
- 11306129E
- Built
- 1965 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Privately Owned Academic School - Charter
- Parcel size
- 2.69 acres
- Building area
- 25,528 sq ft (assessor record)
- Sewer
- Connection on file (2002, 2009) (county sewer connection records)
- Flood zone
- AE — Special Flood Hazard Area (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 combo permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalCurrentLast permitted 2019 (7 years ago). City inspection record: MECHANICAL - FINAL approved 2019-08-05. Contractor of record: CANYON BUILDING AND DESIGN LLC *APA*. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T19CM02836 — removing exsisting evap cooler and installing mini split system
- Fire alarm & life safetyGetting onLast permitted 2009 (17 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T09BU00689 — FIRE ALARM
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2021. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2000-06-30 | $925,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2023-07-31 (TE-FPU-0723-00272) — Site plan for new grading for drainage control..
Permit history (42)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-07-31 | TE-FPU-0723-00272City permit record | Floodplain UseSite plan for new grading for drainage control. | Issued | |
| 2023-06-06expired 2024-06-05 | TD-DEV-0623-00265City permit record | Development PackageSite plan for new grading for drainage control. | Expired | |
| 2022-03-23finaled | T22RW01119City permit record | ROWBarricade only - Work completed - permit needed for slurry seal Previously approved permit T21RW03529 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. UNDER A PAVEMENT MORATORIUM, ANY NEW ASPHALT THAT IS DISTURBED WILL REQUIRE A 2” MILL AND OVERLAY FOR 50’ IN EACH DIRECTION FROM THE OUTSIDE OF THE CUT FOR ALL EFFECTED TRAVEL LANES. 1. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 2. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 3. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 4. MAINTAIN PEDESTRIAN ACCESS 5. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813 | Final | |
| 2021-07-28finaled | T21RW03529City permit record | Pool / spaPRJ203152-1: Cox to Tie into TEP S of E Lowell rd and N Martin Ave. Head N 116' overlashing 48ct Fiber. Riser Down, Bore 39' West, 31' South, 114' West, and 17' to existing vault, tie in. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. | Final | |
| 2019-06-27 | T19OT00593City permit record | FLOODPLNFUP FOR T19CM03986 | Issued | |
| 2019-06-27 | T19OT00595City permit record | FLOODPLNFUP FOR T19CM03984 | Issued | |
| 2019-06-05finaled | T19CM03984City permit record | COMBOINSTALL PV SYSTEM AND RELATED MATERIALS | Final | |
| 2019-06-05finaled | T19CM03985City permit record | COMBOINSTALL PV SYSTEM AND RELATED MATERIALS | Final |
Show 34 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2019-06-05finaled | T19CM03986City permit record | COMBOINSTALL PV SYSTEM AND RELATED MATERIALS | Final | |
| 2019-04-22finaled | T19CM02836City permit record | COMBOremoving exsisting evap cooler and installing mini split system | L of c | |
| 2017-08-04finaled | T17RW03362City permit record | ROWStart Point: from the TEP on the S Side of E Fort Lowell Rd and N Martin Ave begin 130' overlash heading North. Riser down, begin double stuff through existing conduit 333' feet to out of ROW | Final | |
| 2009-05-13 | T09BU00686City permit record | BUILDFIRE ALARM | Withdrwn | |
| 2009-05-13finaled | T09BU00689City permit record | BUILDFIRE ALARM | Final | |
| 2009-04-10expired 2009-06-09 | T09EX00224City permit record | EXCAVTRENCH 15'P (INSTALL FIRE HYDRANT) (APA) | Closed | |
| 2009-04-08expired 2009-06-07 | T09EX00217City permit record | EXCAVEXCA:187LF TO PLACE 2"PVC CONDUIT FOR COX | Closed | |
| 2008-12-09finaled | T08CM03838City permit record | COMBONEW: BUILDING; CLASSROOM | C of o | |
| 2005-08-04finaled | T05BU01962City permit record | BUILDFIRE ALARM SYSTEM | Final | |
| 2005-05-26finaled | T05OT01336City permit record | FLOODPLNFLOODPLAIN USE PERMIT | Final | |
| 2005-05-24finaled | T05CM02379City permit record | COMBOTI: SCHOOL | Final | |
| 2005-05-24finaled | T05CM02380City permit record | COMBOTI: SCHOOL | C of o | |
| 2004-07-08finaled | T04OT01363City permit record | SIGNSIGN:7427 | Final | |
| 2004-07-08expired 2005-04-20 | T04OT01364City permit record | SIGNSIGN:7426 | Expired | |
| 2004-07-08finaled | T04OT01365City permit record | FLOODPLNFLOODPLAIN USE PERMIT | Final | |
| 2004-06-18finaled | T04CM02801City permit record | COMBOTI:OFFICE | Final | |
| 2004-06-17finaled | T04CM02775City permit record | COMBOTI:TOILET ROOMS AND VENDING REMODEL EXISTING VENDING ROOM TO TOILET ROOMS AND RELOCATE VENDING AREA IN EXISTING. | Final | |
| 2002-02-13finaled | T02CM00872City permit record | Addition / alterationADDITION:WATER HEATER/ELECTRICAL | Final | |
| 2002-02-01finaled | T02BU00335City permit record | BUILDFIRE SPKR:MODIFY FIRE ALARM SYSTEM | Final | |
| 2001-10-11finaled | T01CM05094City permit record | COMBOADDITON:SCIENCE LABS | C of o | |
| 2001-03-19finaled | T01BU00704City permit record | BUILDFIRE ALARM | Final | |
| 2001-03-16expired 2001-09-30 | T01BU00698City permit record | Addition / alterationADDITION:CARPORT | Expired | |
| 2001-03-08finaled | T01BU00586City permit record | GRADINGGRADING:CUT 400CY FILL 3100CY | Final | |
| 2001-02-26expired 2001-04-27 | T01EX00243City permit record | EXCAVEXCAV:10' IN PAVEMENT | Closed | |
| 2001-01-31expired 2001-04-01 | T01EX00136City permit record | EXCAVEXCAV:50LF UTLIITY TRENCH | Closed | |
| 2001-01-17expired 2001-03-18 | T01EX00076City permit record | EXCAVEXCAV:150 LF CURB CUTS/RETURNS/RAMPS | Closed | |
| 2000-10-30expired 2001-04-28 | T00BU03199City permit record | BUILDFIRE:ALARM:NEW | Expired | |
| 2000-09-22finaled | T00CM04736City permit record | COMBOREMODEL:SCHOOL OFFICE & SITE | C of o | |
| 2000-09-22finaled | T00CM04738City permit record | Addition / alterationADDITION:CLASSROOM | C of o | |
| 2000-09-14finaled | T00CM04598City permit record | COMBOTI:SCHOOL | C of o | |
| 2000-08-16finaled | T00CM04052City permit record | COMBOTI:CLASSROOMS BLDG 2 | C of o | |
| 2000-07-18 | T00AN00543City permit record | ADDRNEW | Issued | |
| 2000-07-11finaled | T00OT00144City permit record | C-OF-OC OF O: PRESIDIO SCHOOL | Final | |
| 2000-06-14finaled | T00CM02973City permit record | COMBOREMODEL SCHOOL ASSEMBLY BUILDING #1 | C of o |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (3)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2012-07-20 | T12DV06052Code enforcement case | Code enforcement case | Noverify |
| 2007-08-09 | T07DV07463Code enforcement case | Code enforcement case | Invalid |
| 2006-08-30 | T06ZV00660Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 11306129E — 42 permits on file from 2000 to 2023 (14 combo, 6 build, 5 excav, 4 floodpln) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).