Electrical permit history — 3705 N Campbell Av

3705 N Campbell Av, Tucson — built 1981, with 239 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

3705 N Campbell Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1981 — 1980s commercial stock · HVAC 2010 (finaled)

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 special events fire permit - vendor permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service or distribution work shows in the record we read. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalLikely dueLast permitted 2010 (16 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T10ME00080 — Replace 5 ton 3 phase gas package unit. Roof mounted. Like for like.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0824-00634 — Adding two (2) sprinkler pendants to existing system for remodel of DUG room.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2020. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2021. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 128,613 sq ft (county building-footprint layer, 4 structures)
Usable for solar, planning estimate
≈ 90,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 990 kW — roughly 2,480 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,630,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$130,000–$212,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 3.5 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11301146Z
Year constructed
1981 (assessor record)
Permitting authority
Tucson
Zoning
C-1
Property type
Neighborhood Shopping Center
Building area
93,217 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 239 building permits for this parcel dated between 1997 and 2026. By category the work is permanent sign (76), addition / alteration (43), trade permit (34) and fire automatic extinguishing system (31). 192 of them carry a final inspection; the other 47 were issued, expired or are still open, which is not the same as work completed. There are 32 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11301146Z. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85719 · Commercial & industrial reports · Homes in 85719 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N CAMPBELL AV hold 4,143 City permits on record, 860 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (271 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TF-FOP-0526-00631Special Events Fire Permit - VendorComplete
2026CE-VIO0426-01534RefuseClosed - Unfounded
2026CE-VIO0126-00432GraffitiClosed - Unfounded
2026recordRight-of-Way (ROW) Permit - UtilityComplete
2025TF-FOP-0525-00647Special Events Fire Permit - VendorComplete
2025CE-VIO0325-00906VegetationClosed - Resolved
2024TF-FOP-1224-01413Special Events Fire Permit - VendorComplete
2024CE-VIO1024-04262RefuseClosed - Unfounded
2024TF-FCP-0824-00634Fire Automatic Extinguishing System PermitComplete
2024TF-FOP-0424-00520Special Events Fire Permit - VendorComplete
2024TC-COM-0923-02144Commercial Addition/Alteration PermitInspections Complete
2023TF-FOP-1223-01895Special Events Fire Permit - VendorComplete
2023TS-PRM-1023-00541Permanent Sign PermitIssued
2022TF-FOP-1122-00111Special Events Fire Permit - VendorComplete
2022CE-VIO1122-00533RefuseClosed - Unfounded
2022TC-COM-1122-00073Commercial Addition/Alteration PermitExpired
2022T22CM06995Commercial Addition/Alteration PermitExpired
2022T22DV03776Code enforcement caseClosed - Unfounded
2022T22OT00400Permanent Sign PermitFees Due
2022T22CFW0029Special Events Fire Permit - VendorComplete
2022T22FC00139Fire Automatic Extinguishing System PermitComplete
2022T22CM01069Commercial Trade PermitExpired
2022T21CM08317Commercial Addition/Alteration PermitComplete
2021T21CFW0101Special Events Fire Permit - VendorComplete
2021T21OT00869Permanent Sign PermitComplete
2021T21FC00749Fire Automatic Extinguishing System PermitComplete
2021T21OT00457Permanent Sign PermitExpired
2021T21CM06110Commercial Addition/Alteration PermitComplete
2021T21CM05041Commercial Addition/Alteration PermitComplete
2021T21CM06541Commercial Trade PermitComplete
2021T21CM06565Commercial Trade PermitComplete
2021T21OT00540Permanent Sign PermitComplete
2021T21CFW0042Special Events Fire Permit - VendorComplete
2021T20OT00774Permanent Sign PermitComplete
2020T20CFW0103Special Events Fire Permit - VendorComplete
2020T20CM06209Commercial Addition/Alteration PermitApproved
2020T20CM03117Commercial Trade PermitComplete
2020T20CFW0006Special Events Fire Permit - VendorComplete
2020T20OT00258Permanent Sign PermitComplete
2020T20FC00138Fire Automatic Extinguishing System PermitComplete
2020T20CM00383Commercial Trade PermitComplete
2020T20FC00039Fire Automatic Extinguishing System PermitComplete
2020T19CFW0099Special Events Fire Permit - VendorComplete
2019T19CM09056Commercial Addition/Alteration PermitComplete
2019T19OT01065Permanent Sign PermitExpired
2019T19CM07268Commercial Trade PermitComplete
2019T19CFW0028Special Events Fire Permit - VendorComplete
2019T19OT00503Permanent Sign PermitExpired
2019T19FC00313Fire Automatic Extinguishing System PermitComplete
2019T19FC00270Fire Automatic Extinguishing System PermitComplete
2019T18CM09617Commercial Addition/Alteration PermitComplete
2018T18CM09640Commercial Addition/Alteration PermitCanceled
2018T18CFW0099Special Events Fire Permit - VendorComplete
2018T18FO00737General Operational Fire PermitComplete
2018T18CM06064Residential Trade PermitComplete
2018T18CM06052Commercial Trade PermitComplete
2018T18OT00832Residential Addition/Alteration PermitWithdrawn
2018T18CFW0026Special Events Fire Permit - VendorComplete
2018T18FO00249General Operational Fire PermitComplete
2017T17CFW0106Special Events Fire Permit - VendorComplete
2017T16BU00819Commercial Trade PermitComplete
2017T17DV04781MULTIPLE TYPESCOMPLIAN
2017T17DV03400MULTIPLE TYPESREFERRED
2017T17FO00306General Operational Fire PermitComplete
2017T17CFW0030Special Events Fire Permit - VendorComplete
2017T17FO00295General Operational Fire PermitWithdrawn
2016T16OT01443Permanent Sign PermitComplete
2016T16CFW0099Special Events Fire Permit - VendorComplete
2016T16OT01209Permanent Sign PermitComplete
2016T16CM05260Commercial Addition/Alteration PermitComplete
2016T16CFW0030Special Events Fire Permit - VendorComplete
2016T16OT00480Annual Portable Sign ComplianceComplete
2016T16DV00438SIGN VIOLATIONCOMPLIAN
2015T15DV09688PEDDLERSCOMPLIAN
2015T15CFW0101Special Events Fire Permit - VendorComplete
2015T15OT00954Permanent Sign PermitCanceled
2015T15CM03341Commercial Trade PermitComplete
2015T15OT00581Commercial Addition/Alteration PermitComplete
2015T15CFW0031Special Events Fire Permit - VendorComplete
2015T15DV00970EMERGENCYCOMPLIAN
2014T14CFW0082Special Events Fire Permit - VendorComplete
2014T14CM05950Commercial Trade PermitComplete
2014T14DV07072EMERGENCYCOMPLIAN
2014T14OT00708Permanent Sign PermitCanceled
2014T14DV03738ES: INSIDE CONTAINER VIOLATIONCOMPLIAN
2014T14DV03190ILLEGAL DUMPINGCOMPLIAN
2014T14CFW0010Special Events Fire Permit - VendorComplete
2014T14OT00299Permanent Sign PermitCanceled
2014T14CM00317Commercial Trade PermitComplete
2013T13DV09498REFUSECOMPLIAN
2013T13CFW0120Special Events Fire Permit - VendorComplete
2013T13OT01311Permanent Sign PermitCanceled
2013T13OT00867Permanent Sign PermitCanceled
2013T13CM04181Commercial Trade PermitComplete
2013T13CFW0031Special Events Fire Permit - VendorComplete
2013T13CM00277Commercial Trade PermitComplete
2012T12OT01635Permanent Sign PermitCanceled
2012T12BU01357Fire Automatic Extinguishing System PermitCanceled
2012T12CFW0078Special Events Fire Permit - VendorComplete
2012T12DV09114REFUSECOMPLIAN
2012T12CFW0044Special Events Fire Permit - VendorComplete
2012T12DV00465ILLEGAL DUMPINGNOVERIFY
2011T11CFW0120Special Events Fire Permit - VendorComplete
2011T11OT01158Permanent Sign PermitComplete
2011T11OT01234Permanent Sign PermitCanceled
2011T11OT01236Permanent Sign PermitCanceled
2011T11CFW0037Special Events Fire Permit - VendorComplete
2011T11DV02234SIGN VIOLATIONCOMPLIAN
2011T11PL00547Commercial Trade PermitComplete
2011T11OT00445Commercial Addition/Alteration PermitCanceled
2011T11DV01003SIGN VIOLATIONCOMPLIAN
2010T10OT02712Permanent Sign PermitComplete
2010T10OT02714Permanent Sign PermitComplete
2010T10OT02697Annual Portable Sign ComplianceComplete
2010T10OT02698Annual Portable Sign ComplianceComplete
2010T10CFW0045Special Events Fire Permit - VendorCanceled
2010T10OT02258Annual Portable Sign ComplianceComplete
2010T10OT01799Permanent Sign PermitComplete
2010T10OT02014Annual Portable Sign ComplianceComplete
2010T10OT01966Permanent Sign PermitComplete
2010T10EL02165Commercial Trade PermitComplete
2010T10OT01964Annual Portable Sign ComplianceComplete
2010T10OT01936Annual Portable Sign ComplianceComplete
2010T10OT01913Annual Portable Sign ComplianceComplete
2010T10OT01806Permanent Sign PermitComplete
2010T10OT01802Permanent Sign PermitComplete
2010T10OT01805Permanent Sign PermitComplete
2010T10OT01897Annual Portable Sign ComplianceComplete
2010T10OT01817Permanent Sign PermitComplete
2010T10OT01914Annual Portable Sign ComplianceComplete
2010T10OT01801Permanent Sign PermitComplete
2010T10OT01892Annual Portable Sign ComplianceComplete
2010T10OT01797Permanent Sign PermitComplete
2010T10OT01891Annual Portable Sign ComplianceComplete
2010T10OT01853Permanent Sign PermitComplete
2010T10OT01855Annual Portable Sign ComplianceComplete
2010T10BU01148Fire Automatic Extinguishing System PermitComplete
2010T10OT01411Annual Portable Sign ComplianceComplete
2010T09CM01279Commercial Addition/Alteration PermitComplete
2010T10ME00080Commercial Trade PermitComplete
2010T10OT00009Permanent Sign PermitComplete
2009T09OT02782Annual Portable Sign ComplianceCanceled
2009T09DV06531SIGN VIOLATIONCOMPLIAN
2009T09OT02134Annual Portable Sign ComplianceCanceled
2009T09OT02023Commercial Addition/Alteration PermitCanceled
2009T09DV05233SIGN VIOLATIONCOMPLIAN
2009T09DV05234SIGN VIOLATIONCOMPLIAN
2009T09CM01066Commercial Addition/Alteration PermitCanceled
2009T09DV04195SIGN VIOLATIONCOMPLIAN
2009T09BU00862Fire Automatic Extinguishing System PermitComplete
2009T09BU00861Fire Automatic Extinguishing System PermitComplete
2009T09BU00799Fire Automatic Extinguishing System PermitComplete
2009T09OT00969Annual Portable Sign ComplianceComplete
2009T09OT00968Annual Portable Sign ComplianceComplete
2009T09DV02719SIGN VIOLATIONCOMPLIAN
2009T09DV02359SIGN VIOLATIONCOMPLIAN
2009T09DV02358SIGN VIOLATIONCOMPLIAN
2009T09DV02234SIGN VIOLATIONCOMPLIAN
2009T09BU00603Fire Automatic Extinguishing System PermitComplete
2009T09BU00602Fire Automatic Extinguishing System PermitComplete
2009T09BU00505Fire Automatic Extinguishing System PermitComplete
2009T09OT00589Annual Portable Sign ComplianceComplete
2009T09OT00590Permanent Sign PermitComplete
2009T09OT00525Permanent Sign PermitComplete
2009T09DV01230SIGN VIOLATIONCOMPLIAN
2009T09DV00739SIGN VIOLATIONCOMPLIAN
2009T09DV00725SIGN VIOLATIONCOMPLIAN
2009T08CM03470Commercial Addition/Alteration PermitCanceled
2009T08CM03469Commercial Addition/Alteration PermitComplete
2009T09DV00487SIGN VIOLATIONCOMPLIAN
2008T08OT02144Permanent Sign PermitComplete
2008T08CM02677Commercial Addition/Alteration PermitWithdrawn
2008T08OT01659Annual Portable Sign ComplianceCanceled
2008T08OT00909Permanent Sign PermitComplete
2008T08DV02477SIGN VIOLATIONCOMPLIAN
2008T08OT00392Permanent Sign PermitComplete
2008T08OT00097Permanent Sign PermitComplete
2007T07BU02394Fire Automatic Extinguishing System PermitComplete
2007T07DV11945Permanent Sign PermitComplete
2007T07CM03091Commercial Addition/Alteration PermitComplete
2007T07OT01862Permanent Sign PermitCanceled
2007T07OT01714Permanent Sign PermitComplete
2007T07OT01426Permanent Sign PermitComplete
2007T06CM06566Commercial Addition/Alteration PermitComplete
2007T07BU00253Commercial Addition/Alteration PermitComplete
2007T07BU00249Fire Automatic Extinguishing System PermitComplete
2006T06OT03241Permanent Sign PermitComplete
2006T06OT02897Permanent Sign PermitComplete
2006T06CM05704Commercial Addition/Alteration PermitComplete
2006T06CM05545Commercial Addition/Alteration PermitComplete
2006T06BU02432Commercial Addition/Alteration PermitComplete
2006T06BU02314Commercial Trade PermitComplete
2006T06OT02457Commercial Addition/Alteration PermitComplete
2006T06OT00507Commercial Addition/Alteration PermitWithdrawn
2006T06EL00064Residential Trade PermitComplete
2005T05OT02975Permanent Sign PermitComplete
2005T05OT02448Permanent Sign PermitComplete
2005T05OT02117Permanent Sign PermitComplete
2005T05OT01857Permanent Sign PermitComplete
2005T05EL01440Commercial Trade PermitCanceled
2005T05BU01608Commercial Addition/Alteration PermitWithdrawn
2005T05OT01520Permanent Sign PermitComplete
2005T05BU01559Commercial Addition/Alteration PermitComplete
2005T05OT01518Permanent Sign PermitComplete
2005T05OT01519Permanent Sign PermitComplete
2005T05OT01279Permanent Sign PermitComplete
2005T05OT01219Permanent Sign PermitComplete
2005T05EL00820Commercial Trade PermitComplete
2005T05BU00677Commercial Trade PermitComplete
2005T04CM05157Commercial Addition/Alteration PermitComplete
2004T04EL02473Commercial Trade PermitCanceled
2004T04OT02408Permanent Sign PermitComplete
2004T04CM03997Commercial Addition/Alteration PermitCanceled
2004T04BU02694Fire Automatic Extinguishing System PermitComplete
2004T04BU02696Fire Automatic Extinguishing System PermitComplete
2004T04BU02697Fire Automatic Extinguishing System PermitComplete
2004T04BU02808Fire Automatic Extinguishing System PermitComplete
2004T04BU02698Fire Automatic Extinguishing System PermitComplete
2004T04BU02799Fire Automatic Extinguishing System PermitComplete
2004T04BU02645Fire Automatic Extinguishing System PermitComplete
2004T04BU02586Fire Automatic Extinguishing System PermitComplete
2004T04BU02562Fire Automatic Extinguishing System PermitComplete
2004T04BU02570Fire Automatic Extinguishing System PermitComplete
2004T04OT01953Permanent Sign PermitComplete
2004T04CM03721Commercial Addition/Alteration PermitComplete
2003T03PL02079Commercial Trade PermitComplete
2003T03OT02073Permanent Sign PermitComplete
2003T03VL00343Permanent Sign PermitComplete
2003T03OT00408Permanent Sign PermitComplete
2003T03OT00312Commercial Addition/Alteration PermitComplete
2003T03OT00130Permanent Sign PermitComplete
2002T02OT01492Permanent Sign PermitComplete
2002T02OT01442Permanent Sign PermitCanceled
2002T02ME00079Commercial Trade PermitCanceled
2002T02BU00485Fire Automatic Extinguishing System PermitComplete
2002T02OT00250Permanent Sign PermitComplete
2002T02OT00142Permanent Sign PermitComplete
2002T02OT00021Commercial Addition/Alteration PermitWithdrawn
2001T01OT01061Permanent Sign PermitWithdrawn
2001T01OT00981Permanent Sign PermitComplete
2001T01CM03721Commercial Addition/Alteration PermitComplete
2001T01PL01774Residential Trade PermitComplete
2001T01OT00347Permanent Sign PermitWithdrawn
2001T01OT00300Permanent Sign PermitCanceled
2001T01OT00301Permanent Sign PermitComplete
2001T01VL01799Permanent Sign PermitComplete
2001T01VL00457Permanent Sign PermitComplete
2000T00VL01882Permanent Sign PermitComplete
2000T00VL01626Permanent Sign PermitComplete
2000T00EL00466Commercial Trade PermitCanceled
2000T00ME00008Commercial Trade PermitComplete
1999T99PL02674Residential Trade PermitComplete
1999T99OT00330Commercial Addition/Alteration PermitComplete
1999T99EL02873Commercial Trade PermitWithdrawn
1999T99BU02089Fire Automatic Extinguishing System PermitComplete
1999T99EL01828Commercial Trade PermitCanceled
1999T99CM03211Commercial Addition/Alteration PermitComplete
1999T99PL00928Commercial Trade PermitWithdrawn
1998T98EL01918Commercial Trade PermitComplete
1998T98CM05063Commercial Addition/Alteration PermitComplete
1998T98BU02774Fire Automatic Extinguishing System PermitComplete
1998T98CM04345Commercial Addition/Alteration PermitComplete
1998T98VL00513Permanent Sign PermitComplete
1998T98VL00512Permanent Sign PermitComplete
1998T98VL00511Permanent Sign PermitComplete
1998T98VL00450Permanent Sign PermitComplete
1997T97OT00211Commercial Addition/Alteration PermitComplete
1997T97EL01535Residential Trade PermitComplete
1997T97OT00151Commercial Addition/Alteration PermitComplete
1997T97BU01173Fire Automatic Extinguishing System PermitComplete
1997T97CM00889Commercial Addition/Alteration PermitWithdrawn

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11301146Z — 239 City permits on file from 1997 to 2026 and 32 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).