Electrical permit history — 2507 N Tucson Bl
2507 N Tucson Bl, Tucson — built 1959, with 38 permits on record. Review electrical, HVAC and remodel history with links to official records.
Electrical Property Screening Report · Commercial property
2507 N Tucson Bl
A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.
Verify parcel data at official source ↗
Built 1959 — 1950s commercial stock · HVAC 2005 (finaled)
Permanent link: Electrical permit history for 2507 N Tucson Bl (aztucsonelectricalsolutions.com/property/112064260/2507-n-tucson-bl-tucson-az-85716) · Public records last checked 2026-09-22
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 state licensed facility operational fire permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalLikely dueLast permitted 2005 (21 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T05ME00476 — REPLACE 10TON GAS PACK
- Fire alarm & life safetyFinaled permit foundA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “PROVIDE AND INSTALL REQUIRED FIRE LIFE SAFETY DEVICES FOR THE CONTINUED PROTECTION AT TUCSON VA. A NEW DEDICATED FUNCTION SPRINKLER MONITORING SYSTEM WILL BE INSTALLED.”. Last permitted 2014 (12 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T14BU00327 — RELOCATE 6, EXTEND 3 FIRE SPRINKLERS
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
- Routine
A trade permit was pulled in 2019. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
Solar and energy potential
- Roof footprint
- ≈ 7,694 sq ft (county building-footprint layer)
- Usable for solar, planning estimate
- ≈ 5,400 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 60 kW — roughly 150 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 99,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset at TEP commercial rates
- $8,000–$13,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)
Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 2 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.
Get a commercial solar & switchgear analysis
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot, so no zone is shown here. That is a gap in this page, not a statement about the property. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 112064260 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 112064260
- Year constructed
- 1959 (assessor record)
- Permitting authority
- Tucson
- Zoning
- C-2
- Property type
- Office Building 1 Story
- Building area
- 6,900 sq ft
The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 38 building permits for this parcel dated between 1999 and 2026. By category the work is trade permit (12), addition / alteration (7), mayor council special exception (5) and permanent sign (3). 16 of them carry a final inspection; the other 22 were issued, expired or are still open, which is not the same as work completed. There are 3 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
Commercial building (4): 2026 TC-COM-0526-00757 · 2025 TC-COM-0625-01230 · 2025 TC-COM-0125-00173 · 2022 T22CM05917
Sign (1): 2026 TS-PRM-0826-00285
City permit record (31): 2026 TF-FCP-0526-00351 · 2026 TF-FCP-0326-00198 · 2023 TF-FOP-0423-00768 · 2023 TC-UTL-1222-00035 · 2019 T19CM00715 · 2018 T16CM07975 · 2016 T16SE00137 · 2016 T16CM02038 · 2016 T16SE00030 · 2015 T14CM02914 · 2015 T15CM02028 · 2015 T15SE00010 · 2014 T14BU00327 · 2014 T14CM00991 · 2013 T13SE00117 · 2013 T13BU00982 · 2012 T12BU01490 · 2012 T12CM02972 · 2012 T12BU00292 · 2011 T11CM02185 · 2011 T11CM03145 · 2011 T11BU00852 · 2011 T11SE00021 · 2011 T10CM03536 · 2010 T10SE00102 · 2010 T10PRE0035 · 2009 T09PRE0074 · 2008 T08CM02497 · 2006 T06CM02961 · 2005 T05ME00476 · and 1 older — search the parcel at the office below
Development package (1): 2025 TD-DEV-0925-00243
Code enforcement cases (3): 2010 T10DV08632 · 2010 T10DV06583 · 2010 T10DV06026
Special exception (1): 2009 T09SE00059
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 112064260. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All commercial property · Commercial property in 85716 · Commercial & industrial reports · Homes in 85716 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this property compares nearby
Properties on N TUCSON BL hold 1,260 City permits on record, 349 of them since 2022.
Computed from the same public records as this report — counts and years, not an appraisal.
Complete permit record (41 entries)
Every permit and case we hold for this parcel, newest first. Each number links to the official file.
| Year | Number | Type | Status |
|---|---|---|---|
| 2026 | TC-COM-0526-00757 | Commercial Addition/Alteration Permit | Issued |
| 2026 | TS-PRM-0826-00285 | Permanent Sign Permit | Fees Due |
| 2026 | TF-FCP-0526-00351 | Fire Alarm System Permit | Issued |
| 2026 | TF-FCP-0326-00198 | Fire Automatic Extinguishing System Permit | Issued |
| 2025 | TD-DEV-0925-00243 | Development Package | Inspections |
| 2025 | TC-COM-0625-01230 | Commercial Addition/Alteration Permit | Inspections |
| 2025 | TC-COM-0125-00173 | Commercial Addition/Alteration Permit | Issued |
| 2023 | TF-FOP-0423-00768 | State Licensed Facility Operational Fire Permit | Complete |
| 2023 | TC-UTL-1222-00035 | Cell Tower Building Permit | Inspections Complete |
| 2022 | T22CM05917 | Commercial Trade Permit | Issued |
| 2019 | T19CM00715 | Commercial Trade Permit | Complete |
| 2018 | T16CM07975 | Commercial Trade Permit | Canceled |
| 2016 | T16SE00137 | Mayor Council Special Exception | Approved |
| 2016 | T16CM02038 | Commercial Trade Permit | Complete |
| 2016 | T16SE00030 | Mayor Council Special Exception | Approved |
| 2015 | T14CM02914 | Commercial Trade Permit | Complete |
| 2015 | T15CM02028 | Commercial Trade Permit | Complete |
| 2015 | T15SE00010 | Mayor Council Special Exception | Approved |
| 2014 | T14BU00327 | Fire Automatic Extinguishing System Permit | Complete |
| 2014 | T14CM00991 | Commercial Addition/Alteration Permit | Complete |
| 2013 | T13SE00117 | Mayor Council Special Exception | Approved |
| 2013 | T13BU00982 | Permanent Sign Permit | Complete |
| 2012 | T12BU01490 | Commercial Trade Permit | Complete |
| 2012 | T12CM02972 | Commercial Trade Permit | Canceled |
| 2012 | T12BU00292 | Fire Automatic Extinguishing System Permit | Complete |
| 2011 | T11CM02185 | Commercial Trade Permit | Canceled |
| 2011 | T11CM03145 | Commercial Addition/Alteration Permit | Complete |
| 2011 | T11BU00852 | Permanent Sign Permit | Complete |
| 2011 | T11SE00021 | Mayor Council Special Exception | Canceled |
| 2011 | T10CM03536 | Commercial Addition/Alteration Permit | Canceled |
| 2010 | T10DV08632 | MULTIPLE TYPES | COMPLIAN |
| 2010 | T10DV06583 | WEEDS | COMPLIAN |
| 2010 | T10DV06026 | WEEDS | NOVERIFY |
| 2010 | T10SE00102 | Zoning Examiner Special Exception | Canceled |
| 2010 | T10PRE0035 | Pre-Application Conference | Canceled |
| 2009 | T09SE00059 | Zoning Examiner Special Exception | Approved |
| 2009 | T09PRE0074 | Pre-Application Conference | Canceled |
| 2008 | T08CM02497 | Commercial Addition/Alteration Permit | Complete |
| 2006 | T06CM02961 | Commercial Trade Permit | Withdrawn |
| 2005 | T05ME00476 | Commercial Trade Permit | Complete |
| 1999 | T99EL00319 | Commercial Trade Permit | Complete |
prints this report — permits, comparisons and sources — as a clean document
How this report was built
This is a reading of public records for parcel 112064260 — 38 City permits on file from 1999 to 2026 and 3 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.
The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.