Electrical permit history — 1929 E Grant Rd

1929 E Grant Rd, Tucson — built 1961, with 29 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1929 E Grant Rd

Built 1961 — 1960s commercial stock · 29 permits on record; no permitted panel/service or HVAC work among them

Parcel
112062840
Built
1961 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Restaurant Sit Down
Parcel size
0.31 acres
Building area
3,093 sq ft (assessor record)
Sewer
Connection on file (1952) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1929 E Grant Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0923-01117 — Dedicated Function Fire Alarm system to monitor existing waterflow and tamper switches.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2021-06-30$480,000Warranty Deed
2005-02-16$415,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2023-09-19 (TF-FCP-0923-01117) — Dedicated Function Fire Alarm system to monitor existing waterflow and tamper switches..

Permit history (29)

Permit history for this parcel — 8 of 29 records
DateRecordWhatStatusValue
2023-09-19finaledTF-FCP-0923-01117City permit recordFire ConstructionDedicated Function Fire Alarm system to monitor existing waterflow and tamper switches.Complete
2023-08-02expired 2024-05-14TC-COM-0823-01878City permit recordCommercial BuildingChange in Occupancy - increasing to 150 occupants, no work occuringIssued
2023-08-02finaledTF-FOP-0823-01320City permit recordFire OperationalPlaces of Assembly 240Complete
2023-07-21finaledTF-FCP-0723-00875City permit recordFire Construction*Expedite* NEW 4" FIRELINEComplete
2023-07-21finaledTF-FCP-0723-00877City permit recordFire ConstructionNew fire sprinkler system for the existing tenant.Complete
2023-07-11finaledTR-UTL-0723-02001City permit recordRight-of-Way (ROW) - UtilityInstalling 4" Fire Protection ServiceComplete
2022-12-05expired 2024-05-26TC-COM-1222-00237City permit recordFence / wallinstall exterior pre-fab walk-in cooler and convert existing walled courtyard to exterior patio dining use.Approved
2022-10-31finaledTF-FOP-1022-00005City permit recordFire OperationalPlace of Assembly 82Complete
Show 21 older records
Permit history for this parcel — remaining 21 records
DateRecordWhatStatusValue
2022-09-01finaledT22RW03192City permit recordRight-of-Way (ROW)WO T36194. TEP TO PARK IN ROAD RIGHT OF WAY TO CHANGE OUT 1 OH TRANSFORMER AND RUN APPRX 40' OF SECO; Work Order: T36194Complete
2022-08-15finaledT22FC00569City permit recordFIRECONSINSTALL NEW FIRE SYSTEM FOR KITCHEN HOOD.Final
2022-06-28finaledT22OT00456City permit recordFence / wall1-non illum wall signComplete
2022-06-27finaledT22RW02303City permit recordRight-of-Way (ROW)EXCAVATE APPROX 6'X3' TRENCH TO REPLACE GAS SERVICE IN ALLEY LOCATED NORTH OF PROPERTY. ANY ASPHALT; Work Order: 4467208Complete
2022-05-23expired 2022-11-19T22OT00382City permit recordFence / wall1-cOFC wallsignExpired
2022-04-18DP22-0097City permit recordDevelopment PackageSITE - Mojo Restaurant.Approved
2021-12-10finaledT21CM09437City permit recordAddition / alterationRenovation of existing restaurant. No additional SF. Scope includes; Architecture, Structural, MechaComplete
2014-08-29expired 2015-03-09T14OT01118City permit recordFence / wallC OF C ON NON-CONFORMING DP 9/10/14 / 1- NON-ILLUM WALL SIGN / SIGNS INSTALLED W/O PERMIT DOUBLE FEES APPLYExpired
2012-07-11expired 2013-01-09T12OT01038City permit recordFence / wall1- ILLUM WALL SIGN 20594Expired
2011-04-04expired 2011-10-03T11OT00621City permit recordSIGN19486Sign-pc
2009-10-01expired 2010-05-02T09OT02106City permit recordSIGN17287Closed
2009-07-10expired 2010-01-18T09OT01416City permit recordC-OF-OC OF O: RESTAURANT "SABOR TROPICAL"Expired
2008-09-09T08BU01628City permit recordBUILDEXHAUST HOODWithdrwn
2006-01-12finaledT06OT00110City permit recordSIGN10423Final
2005-10-07finaledT05OT02504City permit recordSIGN9848Final
2005-06-23expired 2005-12-21T05OT01562City permit recordSITELANDSCAPE REVISION T05VL00339 T05ZV00264 CM01730Closed
2005-06-10finaledT05CM02685City permit recordCOMBOTI: RESTAURANTC of o
2005-05-25finaledT05OT01316City permit recordSIGNBANNER: 9076 RAZ MODERN RIVIERA CUISINEFinal
2005-05-02finaledT05BU01061City permit recordBUILDEXHAUST HOOD: FIRE EXTINGUISHING SYSTFinal
2005-04-26finaledT05OT01040City permit recordSIGNSIGN: 8853 RAZ MODERN RIVIERA CUISINEFinal
2005-04-19finaledT05OT00944City permit recordSIGNSIGN:#8853 RAZ MODERN RIVIERA CUISINEFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (7)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 7 of 7 records
DateRecordWhatStatus
2019-01-15T19DV00273Code enforcement caseZoningComplian
2018-07-10T18DV03974Code enforcement caseCode enforcement caseReferred
2015-04-08T15DV02722Code enforcement caseCode enforcement caseComplian
2010-05-13finaledT10FR00950Code enforcement caseCode enforcement caseComplete
2006-01-06finaledT06FR00017Code enforcement caseCode enforcement caseComplete
2005-05-16T05ZV00264Code enforcement caseCode enforcement caseComplian
2005-04-19T05VL00339Code enforcement caseWork without permitComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 112062840 — 29 permits on file from 2005 to 2023 (7 sign, 5 fence / wall, 3 fire construction, 2 fire operational) and 7 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.