Electrical permit history — 2854 N Campbell Av

2854 N Campbell Av, Tucson — built 1960, with 82 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

2854 N Campbell Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1960 — 1960s commercial stock · 82 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 special events fire permit - vendor permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 special events fire permit - vendor permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onA newer 2025 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Replacement of an existing fire alarm control system”. Last permitted 2009 (17 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T09BU00721 — Relocate 5 sprinkler heads.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2003. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2009. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 149,865 sq ft (county building-footprint layer)
Usable for solar, planning estimate
≈ 104,900 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 1,150 kW — roughly 2,880 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,890,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$151,000–$246,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 2.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
112054140
Year constructed
1960 (assessor record)
Permitting authority
Tucson
Zoning
C-1
Property type
Neighborhood Shopping Center
Building area
69,581 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 82 building permits for this parcel dated between 1998 and 2026. By category the work is special events fire permit - vendor (29), permanent sign (18), addition / alteration (14) and fire automatic extinguishing system (8). 65 of them carry a final inspection; the other 17 were issued, expired or are still open, which is not the same as work completed. There are 2 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 112054140. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85719 · Commercial & industrial reports · Homes in 85719 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N CAMPBELL AV hold 4,143 City permits on record, 860 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (84 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TF-FOP-0526-00600Special Events Fire Permit - VendorComplete
2025TF-FOP-0525-00613Special Events Fire Permit - VendorComplete
2025TF-FCP-0125-00071Fire Alarm System PermitExpired
2024TF-FOP-1124-01353Special Events Fire Permit - VendorComplete
2024TS-PRM-1124-00486Permanent Sign PermitInspections Complete
2024TF-FOP-0424-00482Special Events Fire Permit - VendorComplete
2024TF-FOP-1223-01860Special Events Fire Permit - VendorComplete
2023TS-PRM-0923-00505Permanent Sign PermitIssued
2023TC-COM-0623-01455Commercial Addition/Alteration PermitComplete
2022TF-FOP-1122-00081Special Events Fire Permit - VendorComplete
2021T21CFW0113Special Events Fire Permit - VendorComplete
2021T21FC00532Fire Automatic Extinguishing System PermitExpired
2021T21CFW0025Special Events Fire Permit - VendorComplete
2021T21OT00415Permanent Sign PermitComplete
2021T21OT00361Permanent Sign PermitSubmitted
2021T21CM01963Commercial Addition/Alteration PermitExpired
2020T20CFW0117Special Events Fire Permit - VendorComplete
2020T20CM06202Commercial Addition/Alteration PermitApproved
2020T20CFW0011Special Events Fire Permit - VendorComplete
2020T19CFW0073Special Events Fire Permit - VendorComplete
2019T19FO00500General Operational Fire PermitComplete
2019T19CFW0001Special Events Fire Permit - VendorComplete
2018T18CFW0074Special Events Fire Permit - VendorComplete
2018T18CFW0003Special Events Fire Permit - VendorComplete
2017T17CFW0083Special Events Fire Permit - VendorComplete
2017T17CFW0002Special Events Fire Permit - VendorComplete
2016T16CFW0075Special Events Fire Permit - VendorComplete
2016T16CFW0002Special Events Fire Permit - VendorComplete
2015T15CFW0075Special Events Fire Permit - VendorComplete
2015T14CFW0069Special Events Fire Permit - VendorComplete
2015T15CFW0002Special Events Fire Permit - VendorComplete
2014T14CFW0002Special Events Fire Permit - VendorComplete
2014T14CM00329Commercial Addition/Alteration PermitComplete
2013T13CFW0081Special Events Fire Permit - VendorComplete
2013T13SA00122Zoning ComplianceComplete
2013T13CFW0005Special Events Fire Permit - VendorComplete
2012T12CFW0063Special Events Fire Permit - VendorComplete
2012T12CFW0010Special Events Fire Permit - VendorComplete
2012T12OT00500Annual Portable Sign ComplianceCanceled
2011T11CFW0148Special Events Fire Permit - VendorComplete
2011T11DV06210CLEAN CITIES INITIATIVE PGRMNOVERIFY
2011T11CFW0003Special Events Fire Permit - VendorComplete
2011T11OT00388Permanent Sign PermitCanceled
2010T10CFW0012Special Events Fire Permit - VendorCanceled
2010T10OT02498Permanent Sign PermitWithdrawn
2010T10OT01058Permanent Sign PermitComplete
2010T10OT00181Permanent Sign PermitComplete
2010T10OT00182Annual Portable Sign ComplianceCanceled
2009T09OT02153Annual Portable Sign ComplianceCanceled
2009T09OT01302Permanent Sign PermitComplete
2009T09BU00721Fire Automatic Extinguishing System PermitComplete
2009T09BU00767Commercial Trade PermitComplete
2009T09BU00617Commercial Addition/Alteration PermitComplete
2008T08CM03645Commercial Addition/Alteration PermitComplete
2008T08OT02661Permanent Sign PermitComplete
2008T08OT02662Permanent Sign PermitComplete
2008T08OT02660Permanent Sign PermitCanceled
2008T08BU01893Fire Automatic Extinguishing System PermitComplete
2008T08CM02651Commercial Addition/Alteration PermitComplete
2008T08DV01898PAINT DISTCOMPLIAN
2005T05ME00158Commercial Trade PermitComplete
2004T04BU01219Fire Automatic Extinguishing System PermitComplete
2004T04CM01521Commercial Addition/Alteration PermitComplete
2004T04OT00474Permanent Sign PermitComplete
2003T03CM01510Commercial Addition/Alteration PermitComplete
2002T02PL02421Residential Trade PermitWithdrawn
2002T02CM05504Commercial Trade PermitComplete
2002T02OT01871Commercial Addition/Alteration PermitComplete
2002T02EL02200Residential Trade PermitComplete
2002T02OT01723Permanent Sign PermitComplete
2002T02OT01731Commercial Addition/Alteration PermitWithdrawn
2002T02OT01722Permanent Sign PermitComplete
2002T02BU01422Fire Automatic Extinguishing System PermitComplete
2002T02CM00240Commercial Addition/Alteration PermitComplete
2002T02BU00293Fire Automatic Extinguishing System PermitComplete
2001T01OT00836Permanent Sign PermitCanceled
2001T01OT00442Permanent Sign PermitComplete
2001T01VL00451Permanent Sign PermitComplete
2000T00EL00169Commercial Trade PermitComplete
1999T99EL03294Commercial Trade PermitComplete
1999T99CM04621Commercial Addition/Alteration PermitCanceled
1999T99BU01858Fire Automatic Extinguishing System PermitComplete
1999T99CM02658Commercial Addition/Alteration PermitComplete
1998T98BU02345Fire Automatic Extinguishing System PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 112054140 — 82 City permits on file from 1998 to 2026 and 2 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.