Electrical permit history — 2544 E Allen Rd
2544 E Allen Rd, Tucson — built 1933, with 11 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
2544 E Allen Rd
Built 1933 — 1930s commercial stock · last permitted panel/service work 2023 (finaled)
Permanent link: Electrical permit history for 2544 E Allen Rd (aztucsonelectricalsolutions.com/property/112010340/2544-e-allen-rd-tucson-az-85716) · Public records last checked 2026-08-16
- Parcel
- 112010340
- Built
- 1933 (county record)
- Jurisdiction
- Tucson
- Zoning
- HLR-1
- Assessor use
- Club Lodge Or Fraternal Organization
- Parcel size
- 2.10 acres
- Building area
- 871 sq ft (assessor record)
- Sewer
- Connection on file (1975) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Valley of the Moon Historic District — Historic Landmark (City of Tucson)
- Service on record
- City records show the 2023 permit was finalized; the permit description states “Repair of crack in the Rabbit Hole Arch by supporting with new steel beam Bolster thin shell concrete garden walls with supporting wall and make repairs to existing walls 200 amp panel upgrade” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2023 (3 years ago). The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. SD-1023-00111 — Repair of crack in the Rabbit Hole Arch by supporting with new steel beam Bolster thin shell concrete garden walls with supporting wall and make repairs to existing walls 200 amp panel upgrade
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2025-03-03 (SD-0325-00034) — Repairs on Historic Landmark's Wizard Tower, a garden structure with 2 rooms, require a Historic Preservation design review..
Permit history (11)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-03-03finaled 2025-04-29 | SD-0325-00034Design review | Historic Preservation Zone/Historic LandmarkRepairs on Historic Landmark's Wizard Tower, a garden structure with 2 rooms, require a Historic Preservation design review. | Complete | |
| 2025-02-01finaled | TC-COM-0225-00210City permit record | Commercial BuildingRepairs on Historic Landmark's Wizard Tower, a garden structure with 2 rooms, require a Historic Preservation design review. | Complete | |
| 2025-01-29 | TC-COM-0125-00188City permit record | Commercial BuildingVOIDED WRONG PERMIT TYPE We require a Historic Design Plan Review for a repair request on the Wizard Tower, an artist-built historic structure. It is not a typical building, it is a fantasy creation for the entertainment of children. I've called it a commercial building only because there is no good description in the drop downs. We are not building new features. The valuation is based on contractor bid for the project. No trades listed in the following screen is involved. If our property wasn't a historic landmark, I don't think we'd need a permit for the repairs. | Void | |
| 2023-10-06finaled 2023-11-20 | SD-1023-00111Design review | Historic Preservation Zone/Historic LandmarkRepair of crack in the Rabbit Hole Arch by supporting with new steel beam Bolster thin shell concrete garden walls with supporting wall and make repairs to existing walls 200 amp panel upgrade | Complete | |
| 2023-06-27expired 2024-10-16 | TC-COM-0623-01583City permit record | Commercial BuildingNew 200 amp panel, underground elec lines, repairs to the exist structures | Issued | |
| 2023-06-23expired 2023-12-20 | TC-RES-0623-06098City permit record | Trade permitVOIDED NEED TO SUBMIT A COMMERCIAL TRADE PERMIT 200 amp panel upgrade | Void | |
| 2015-12-03expired 2016-06-05 | T15OT01610City permit record | SIGNSIGN | Sign-pc | |
| 2015-11-17finaled | T15CM08072City permit record | Fence / wallZON/ENG WALL UP TO 6FT W. HIST MONUMENT; | Final |
Show 3 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2015-03-24finaled | T15CM01934City permit record | COMBOREPR/REPL ROOF | Final | |
| 2014-09-05finaled | T14CM05851City permit record | COMBOREPLACE PARKING LOT LIGHTNING | Final | |
| 2014-05-23expired 2014-12-14 | T14CM03103City permit record | COMBOADD NEW METER;COMM | Expired |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (7)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-11-20 | CE-VIO1125-05112Code enforcement case | Vegetation | Closed - unfounded |
| 2024-06-10 | CE-VIO0624-02212Code enforcement case | Vegetation | Closed - resolved |
| 2010-10-06finaled | T10FR02046Code enforcement case | Code enforcement case | Complete |
| 2009-11-02finaled | T09FR03427Code enforcement case | Code enforcement case | Complete |
| 2008-04-18finaled | T08FR01002Code enforcement case | Fire | Complete |
| 2008-04-16 | T08DV03115Code enforcement case | Code enforcement case | Referred |
| 2008-03-17 | T08DV02208Code enforcement case | Electrical | Referred |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 112010340 — 11 permits on file from 2014 to 2025 (3 commercial building, 3 combo, 2 historic preservation zone/historic landmark, 1 trade permit) and 7 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.