Electrical permit history — 3536 E Water St

3536 E Water St, Tucson — built 1952, with 38 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

3536 E Water St

Built 1952 — 1950s multifamily stock · last permitted panel/service work 2011 (finaled)

Parcel
111081350
Built
1952 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Apartments 5 - 24 Units 1 Story
Parcel size
0.83 acres
Building area
7,804 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2011 permit was finalized; the permit description states “SERVICE UPGRADE” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 3536 E Water St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2011 (15 years ago). City inspection record: ELECTRIC - FINAL approved 2011-11-10. Contractor of record: J P B ELECTRIC INC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T11EL02871 — SERVICE UPGRADE
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 adu / casita permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onA newer 2015 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “NEW FIRE ALARM FOR R-2”. Last permitted 2009 (17 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T09BU00605 — FIRE ALARM SYSTEM
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    An ADU or casita was permitted in 2024, which means load has already been added to this property. Whether there is headroom left for anything more depends on how that was fed — a subpanel off the existing service, or its own.

  • Worth confirming

    A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2001-03-20$360,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2024-11-14 (TF-FOP-1124-01319) — Adult Treatment Living.

Permit history (38)

Permit history for this parcel — 8 of 38 records
DateRecordWhatStatusValue
2024-11-14finaledTF-FOP-1124-01319City permit recordADU / casitaAdult Treatment LivingComplete
2023-11-30finaledTF-FOP-1123-01824City permit recordADU / casitaAdult Treatment LivingComplete
2021-11-17expired 2022-05-31T21CM08965City permit recordCommercial BuildingCommercial Office Tenant ImprovementExpired
2020-05-13finaledT20RW02705City permit recordPool / spaStarting on the East side of N Sparkman and South of Water riser up TEP pole and Overlash 72' going West continue going North 264' continue East 844' contunie South 44' and Riser down. Tench/bore going South 15' to out of ROW.Final
2017-03-27T17CM02380City permit recordCOMBOA/C REPLACEMENTWithdrwn
2017-03-27T17CM02381City permit recordCOMBOA/C REPLACEMENTWithdrwn
2017-03-24finaledT17RW01352City permit recordROWREPLACING ONE POLE ON THE SOUTH SIDE OF WATER STREET APPROIMATELY 260' WEST OF RICHEY BLFinal
2017-03-10finaledT17CM01969City permit recordCOMBOELECTRICAL UPGRADE UP TO 200AMPSFinal
Show 30 older records
Permit history for this parcel — remaining 30 records
DateRecordWhatStatusValue
2017-03-10finaledT17CM01970City permit recordCOMBOELECTRICAL UPGRADE TO 200 AMPSFinal
2017-03-10finaledT17CM01971City permit recordCOMBOELECTRICAL UPGRADE UP TO 200 AMPSFinal
2017-01-20finaledT17CM00528City permit recordCOMBO2 METER PACKFinal
2017-01-20finaledT17CM00529City permit recordCOMBO2 METER PACKFinal
2016-11-01finaledT16CM08268City permit recordCOMBONEW GASL LINE FROM METER TO HOMEFinal
2016-06-01T16CM04098City permit recordCOMBOCONVERT RESIDENCE TO OUTPATIENT BEHAVIORAL HEALTHWithdrwn
2016-04-06expired 2016-10-31T16CM02522City permit recordCOMBOADD 400 SQ FT STORAGE SHEDExpired
2016-03-02finaledT16CM01613City permit recordCOMBOEXTERIOR GAS LINEFinal
2015-03-06expired 2015-10-11T15BU00241City permit recordBUILDNEW FIRE ALARM FOR R-2Expired
2012-01-25finaledT12PL00144City permit recordPLUMBREPLACE GAS LINE; DUPLXFinal
2011-11-02finaledT11EL02871City permit recordELECTSERVICE UPGRADEFinal
2011-02-22finaledT11PL00341City permit recordPLUMBREPLACE GAS LINEFinal
2009-04-27finaledT09BU00605City permit recordBUILDFIRE ALARM SYSTEMFinal
2009-01-12finaledT09BU00036City permit recordBUILDNEW FIRE ALARM SYSTEMFinal
2009-01-12finaledT09BU00037City permit recordBUILDNEW FIRE ALARM SYSTEMFinal
2009-01-12finaledT09BU00038City permit recordBUILDNEW FIRE ALARM SYSTEMFinal
2008-10-09T08EL01940City permit recordELECT200 amp all-in-one serviceWithdrwn
2004-02-23finaledT04PL00347City permit recordPLUMBREPLACE:GAS LINEFinal
2004-02-23finaledT04PL00348City permit recordPLUMBREPLACE:GAS LINEFinal
2004-02-23finaledT04PL00349City permit recordPLUMBREPLACE:GAS LINEFinal
2003-12-12finaledT03PL02098City permit recordPLUMBPLUMBING:WATER LINE APAFinal
2003-08-19expired 2004-02-18T03EL01655City permit recordELECTUPGRADE:ELECTRIC TO 200AMP (APA)Closed
2001-04-30T01OT00113City permit recordC-OF-OC OF O:TRANSITIONAL RESIDENTIAL TREATMENT PROGRAMWithdrwn
2001-04-30T01OT00114City permit recordC-OF-OC OF O:TRANSITIONAL RES. TREATMENT PROGRAMWithdrwn
2001-03-15T01OT00077City permit recordC-OF-OC OF O:TRANSITIONAL HOUSING FOR VETSWithdrwn
2001-03-15T01OT00078City permit recordC-OF-OC OF O:TRANSITIONAL HOUSING FOR VETSWithdrwn
2000-02-10finaledT00EL00359City permit recordELECTELECTRIC:UNDERGROUD WIRINGFinal
2000-02-10finaledT00EL00360City permit recordELECTELECTRIC:UNDERGROUND WIRINGFinal
2000-02-10expired 2000-08-16T00EL00361City permit recordELECTELECTRIC:UNDERGROUND WIRINGExpired
1999-10-14finaledT99PL02200City permit recordPLUMBGAS LINE:REPAIRFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (4)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 4 of 4 records
DateRecordWhatStatus
2015-10-20T15DV08026Code enforcement caseRefuseComplian
2010-11-09T10DV08101Code enforcement caseFireNoverify
2010-06-25T10DV04166Code enforcement caseCode enforcement caseCourtcmp
2000-01-26T00VL00089Code enforcement caseCode enforcement caseClosed

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 111081350 — 38 permits on file from 1999 to 2024 (11 combo, 7 plumb, 6 elect, 5 build) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.