Electrical permit history — 3155 E Grant Rd

3155 E Grant Rd, Tucson — built 1970, with 22 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3155 E Grant Rd

Built 1970 — 1970s commercial stock · 22 permits on record; no permitted panel/service or HVAC work among them

Parcel
11107313C
Built
1970 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
State School Prop
Parcel size
19.83 acres
Building area
139,963 sq ft (assessor record)
Sewer
Connection on file (2003) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3155 E Grant Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 fireoper permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 fireoper permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onLast permitted 2007 (19 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T07BU00760 — 250 New Fire Sprinklers and 10' new underground
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2026-07-17 (TE-FPU-0726-00295) — P.279537-1 : ACCESS HH 14804, MH 6238, MH 8453, MH 9831, MH 6988A, & MH 6988 FOR SPLICING Please Expedite permit.

Permit history (22)

Permit history for this parcel — 8 of 22 records
DateRecordWhatStatusValue
2026-07-17TE-FPU-0726-00295City permit recordFloodplain UseP.279537-1 : ACCESS HH 14804, MH 6238, MH 8453, MH 9831, MH 6988A, & MH 6988 FOR SPLICING Please Expedite permitIssued
2026-05-25expires 2026-08-31TR-ROW-0526-00623City permit recordRight-of-Way (ROW)The Tucson Police Department will be installing camera systems at 70 locations. An excel spreadsheet has been included with all the locations and pole numbers, as well as, a traffic control plan. TPD will be utilizing a TPD marked vehicle to assist with traffic safety. This permit will serge for streetlight(s): #14870 3026 E Grant RdIssued
2026-02-05expires 2026-08-26TR-UTL-0226-00217City permit recordRight-of-Way (ROW) - UtilityP.279537-1 : ACCESS HH 14804, MH 6238, MH 8453, MH 9831, MH 6988A, & MH 6988 FOR SPLICING Please Expedite permitIssued
2025-05-05finaledTR-ROW-0525-00597City permit recordRight-of-Way (ROW)Need a lane closure and side walk detour for paving private property. Traffic Control has been approved for 24hrs for Right lane closure to accommodated Pedestrian detour routeComplete
2024-05-15finaledTR-UTL-0524-00968City permit recordRight-of-Way (ROW) - Utility20 signs to be put in ROW to provide notice to neighbors of upcoming TEP line siting hearing. Addresses/locations provided are the closest physical address to the sign ROW location. The signs will be 24x36" signs printed on corrugated plastic. We'd like to get the signs up the week of June 3 and have them up through the hearing, July 22.Complete
2024-01-11finaledTR-UTL-0124-00078City permit recordRight-of-Way (ROW) - Utility20 open house signs to be put in ROW to provide notice to neighbors of upcoming TEP open house. Addresses/locations provided are the closest physical address to the sign ROW location. The signs will be 18x24" "campaign style" (on a wire frame) type signs. We'd like to get the signs up Jan.26 or Jan.29 so they are up about two weeks prior to our open house on Feb. 8.Complete
2023-09-27TR-UTL-0923-02594City permit recordRight-of-Way (ROW) - Utility2602726 3155 E. Grant Rd 13-14-33SW Replace missing hydrant South of the lot in shoulder:6lf dirt/ mlmNeeds resubmittal
2023-01-17finaledTR-UTL-0123-00621City permit recordRight-of-Way (ROW) - UtilityTwo (2) 5x5 bellholes in blk top for crews to repair gas lineComplete
Show 14 older records
Permit history for this parcel — remaining 14 records
DateRecordWhatStatusValue
2022-11-01TF-FCP-1122-00012City permit recordFire ConstructionVOID-BELONGS TO STATE FM-Installing new fire alarm panel and cellular radio for monitoring existing fire alarm systemVoid
2020-09-09finaledT20RW04971City permit recordPool / spaN.735723 (I) - JOB WILL REQUIRE 304' OF BORING, 24 OF TRENCHING ADDRESS ON APP IS 3075 E GRANT RD ONE POT HOLE IN PAVEMENT IN DRIVEWAY, OTHERWISE WORK IS OUT OR THE ROADWAY. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION MAINTAIN PEDESTRIAN ACCESSFinal
2019-12-11finaledT19RW07494City permit recordROWN.604023 JOB WILL REQUIRE ACCESS TO MH#'S 6238, 8268, 7646, 8918, 8518, 10160, 9606, 10974, 10629, 12716, 11854, 14254, 13591, 15574, 14914, 16331 AND 11613 TO SPLICE FIBER.Final
2019-06-04finaledT19RW03143City permit recordROWCREW TO PARK IN ROW BEHIND CURB, IN ORDER TO REMOVE EXISTING OH 30 TRANSFORMERS CREW TO PARK BEHIND CURB TO REMOVE UNUSED OH TRANSFORMERS.Final
2018-08-15finaledT18FO00679City permit recordFIREOPERPLACES OF ASSEMBLY - OCC LOAD 634Final
2017-11-15finaledT17FO00981City permit recordFIREOPERWORK DINER - 1 TENT SETUP DATE 11/19/17Final
2017-10-04finaledT17FO00838City permit recordFIREOPEROCC 634 FEM - PLACES OF ASSEMBLY - ANNUAL FIRE INSPECTIONFinal
2017-04-27finaledT17RW01804City permit recordROWEXISTING PAVEMENT SAMPLING TO A DEPTH OF ONE FOOT, 4" DIAMETER, 7 LOCATIONS COUNTRY CLUB RD, GRANT RD TO FORT LOWELL RD TUCSON PAVEMENT RECONSTRUCTION - FY18 - PACKAGE 2Final
2016-02-23finaledT16EX00534City permit recordEXCAV(2) 5x5 ASPHALT/SIDEWALK ON COUNTRY CLUB SIDE OF PROPERTY TO POTHOLE GAS LINEFinal
2016-02-23finaledT16TC00438City permit recordBARRICAD(2) 5x5 ASPHALT/SIDEWALK ON COUNTRY CLUB SIDE OF PROPERTY TO POTHOLE GAS LINEFinal
2013-01-25expired 2013-03-26T13EX00083City permit recordEXCAVBORE 75' ACROSS COUNTRY CLUB AT DOOLEN MIDDLE SCHOOL & PLACE HANDHOLE FOT TUSD FIBER OPTIC IMPROVEMENT ** BORING FORM REQUIRED ** MUST MEET WITH PERMITS & CODES INSPECTOR TOM WOLFGANG AT 400-7395 FOR PRE-CONSTRUCTION MEETING PRIOR TO START OF WORK.Closed
2011-09-19finaledT11EL02472City permit recordELECTDEMO 12 SPORT LIGHT POLES FOR MIDDLE SCHOOLFinal
2007-04-06finaledT07BU00760City permit recordSPKLR250 New Fire Sprinklers and 10' new undergroundFinal
2007-02-21finaledT07BU00401City permit recordBUILDADD TO EXISTING FIRE ALARMFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11107313C — 22 permits on file from 2007 to 2026 (5 right-of-way (row) - utility, 3 row, 3 fireoper, 2 right-of-way (row)) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).