Electrical permit history — 3472 E Fort Lowell Rd
3472 E Fort Lowell Rd, Tucson — built 1960, with 26 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3472 E Fort Lowell Rd
Built 1960 — 1960s commercial stock · HVAC 2007 (finaled)
Permanent link: Electrical permit history for 3472 E Fort Lowell Rd (aztucsonelectricalsolutions.com/property/11105076b/3472-e-fort-lowell-rd-tucson-az-85716) · Public records last checked 2026-08-17
- Parcel
- 11105076B
- Built
- 1960 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Day Care/Pre-School Center Private
- Parcel size
- 0.90 acres
- Building area
- 5,463 sq ft (assessor record)
- Sewer
- Connection on file (2007, 2010) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalLikely dueLast permitted 2007 (19 years ago). City inspection record: ELECTRIC - FINAL approved 2007-09-17. Contractor of record: NICHOLS CONTRACTING CO INC *C. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T07CM01608 — REPLACE 2 1/2 TON TON HEAT PUMP & ELECTRIC
- Fire alarm & life safetyCurrentLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00660 — BAY ALARM TO INSTALL ONE (1) DMP LTE DUALCOM FIRE RADIO TO CURRENT FIRE PANE
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Solar was permitted here in 2017. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2004-04-16 | $675,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-09-24 (TF-FOP-0925-01264) — Childcare Center Annual Fire Permit.
Permit history (26)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-09-24finaled | TF-FOP-0925-01264City permit record | Fire OperationalChildcare Center Annual Fire Permit | Complete | |
| 2024-10-02finaled | TF-FOP-1024-01115City permit record | Fire OperationalAnnual inspection required by state licensing. | Complete | |
| 2023-09-13finaled | TF-FOP-0923-01499City permit record | Fire OperationalSmall Miracles Outer Limits Daycare 196 Children Annual Fire Permit | Complete | |
| 2022-08-08finaled | T22FO00672City permit record | FIREOPEROUTER LIMITS SCHOOL - 196 PEOPLE | Final | |
| 2021-04-20finaled | T21FO00244City permit record | FIREOPERSMALL MIRACLES- OUTER LIMITS SCHOOL 203 PERSONS CUSTOMER PAID TWICE REFUNDED - LASERFICHE 37686 YVETTE MONTIJO | Final | |
| 2020-10-13finaled | T20FC00660City permit record | FIRECONSBAY ALARM TO INSTALL ONE (1) DMP LTE DUALCOM FIRE RADIO TO CURRENT FIRE PANE | Final | |
| 2020-05-19finaled | T20FO00282City permit record | FIREOPERCHILDRENS ENDEAVORS/SMALL MIRACLES - OCC LOAD: 203 | Final | |
| 2019-10-28finaled | T19RW06598City permit record | ROWInstallation of small cell equipment mounted on existing Cox strand on the west side of 3472 E Ft Lowell Rd | Final |
Show 18 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2019-04-29finaled | T19FO00313City permit record | FIREOPEROCC- LOAD 172 | Final | |
| 2018-03-20finaled | T18FO00240City permit record | FIREOPERChild Day Care - 203 Occ Load | Final | |
| 2017-04-03finaled | T17CM02523City permit record | Solar PVSOLAR PV | Final | |
| 2016-11-22expired 2017-07-02 | T16CM08823City permit record | Solar PVPV SOLAR | Withdrwn | |
| 2012-05-14finaled | T12CM02671City permit record | COMBOSTEEL FRAMED MESH CANOPY OVER PLAYGROUND | Final | |
| 2012-04-03finaled | T12OT00528City permit record | SIGNA-FRAME | Final | |
| 2012-03-07finaled | T12BU00317City permit record | BUILDFIRE ALARM | Final | |
| 2012-02-09finaled | T12BU00204City permit record | BUILDFIRE ALARM | Final | |
| 2010-05-05finaled | T10CM01237City permit record | Addition / alterationCLASSROOM:ADDITION/INTERIOR REMODEL | C of o | |
| 2007-04-18finaled | T07CM01608City permit record | COMBOREPLACE 2 1/2 TON TON HEAT PUMP & ELECTRIC | Final | |
| 2007-02-08finaled | T07BU00296City permit record | BUILDKITCHEN EXHAUST HOOD | Final | |
| 2006-12-11expired 2007-02-09 | T06EX01184City permit record | EXCAVREMOVE AND REPLACE ASPHALT. 24'X20' | Closed | |
| 2005-11-14finaled | T05CM05714City permit record | Addition / alterationADDITION:OFFICE | C of o | |
| 1999-09-10 | T99BU02496City permit record | Addition / alterationADDITION:PORCH (MODULAR:DAY CARE) | Withdrwn | |
| 1999-08-19finaled | T99BU02277City permit record | BUILDFIRE ALARM | Final | |
| 1999-08-17expired 2000-02-27 | T99BU02244City permit record | SPKLRFIRE SPKR:ADD 9 | Expired | |
| 1999-05-06expired 1999-07-05 | T99EX00471City permit record | EXCAVEXCAV:TRENCH 20LF | Closed | |
| 1998-09-02finaled | T98CM03765City permit record | COMBOMODULAR:DAY CARE | C of o |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (8)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2020-05-07 | T20DV03131Code enforcement case | Code enforcement case | Noverify |
| 2016-01-19 | T16DV00279Code enforcement case | Code enforcement case | Complian |
| 2015-02-04 | T15DV00678Code enforcement case | Vegetation | Complian |
| 2014-04-11 | T14DV02317Code enforcement case | Refuse | Noverify |
| 2013-09-03 | T13DV06505Code enforcement case | Refuse | Complian |
| 2012-09-14 | T12DV08557Code enforcement case | Refuse | Complian |
| 2009-03-11finaled | T09FR00899Code enforcement case | Fire | Complete |
| 2008-10-21 | T08FR03836Code enforcement case | Code enforcement case | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 11105076B — 26 permits on file from 1998 to 2025 (5 fireoper, 4 build, 3 fire operational, 3 combo) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.