Electrical permit history — 3426 E Kleindale Rd

3426 E Kleindale Rd, Tucson — built 1962, with 48 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

3426 E Kleindale Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1962 — 1960s multifamily stock · 2 open code cases · 48 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2014 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2014 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There are 2 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2021. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    There is an electrical reconnect permit from 2014. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Solar and energy potential

Roof footprint
≈ 14,247 sq ft (county building-footprint layer, 7 structures)
Usable for solar, planning estimate
≈ 10,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 110 kW — roughly 280 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 180,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$14,000–$23,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 2.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
111041550
Year constructed
1962 (county record)
Permitting authority
Tucson
Zoning
R-3
Property type
Apartments 5 - 24 Units 1 Story
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 48 building permits for this parcel dated between 1997 and 2025. By category the work is commercial building (19), plumb (12) and elect (4). 20 of them carry a final inspection; the other 28 were issued, expired or are still open, which is not the same as work completed. There are 23 code-enforcement cases recorded against the parcel, 2 of which are open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 111041550. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85716 · Commercial & industrial reports · Homes in 85716 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

Complete permit record (71 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0826-03365RefuseNotice of violation
2026CE-VIO0726-02765RefuseClosed - resolved
2026CE-VIO0426-01679Code enforcement caseClosed - resolved
2026CE-VIO0426-01677Code enforcement caseCitation
2025TC-COM-0525-01036Commercial BuildingComplete
2024TC-COM-0724-01433Commercial BuildingComplete
2024TC-COM-0424-00578Commercial BuildingVoid
2024TC-COM-0424-00579Commercial BuildingIssued
2024TC-COM-0424-00580Commercial BuildingIssued
2024TC-COM-0424-00581Commercial BuildingIssued
2024TC-COM-0424-00582Commercial BuildingVoid
2024TC-COM-0424-00583Commercial BuildingIssued
2024TC-COM-0424-00586Commercial BuildingIssued
2024TC-COM-0424-00587Commercial BuildingVoid
2024TC-COM-0424-00588Commercial BuildingIssued
2024TC-COM-0424-00589Commercial BuildingVoid
2024TC-COM-0424-00590Commercial BuildingIssued
2024TC-COM-0324-00531Commercial BuildingIssued
2024TC-COM-0324-00532Commercial BuildingIssued
2024TC-COM-0324-00533Commercial BuildingIssued
2024TC-COM-0324-00534Commercial BuildingIssued
2024TC-COM-0324-00535Commercial BuildingIssued
2023TC-COM-0223-00708Commercial BuildingExpired
2023TC-COM-0223-00709Commercial BuildingVoid
2023TC-COM-0123-00506Commercial BuildingVoid
2023TC-COM-0123-00507Commercial BuildingFees due
2022TC-RES-1122-00367Residential Building - One or Two FamilyIssued
2022T22DV06013Code enforcement caseClosed - resolved
2022T22CM07563Commercial BuildingExpired
2022DP22-0037Development PackageComplete
2021T21DV08613VegetationNoverify
2021T21DV08494Code enforcement caseComplian
2021T21DV08263Code enforcement caseComplian
2021T21BU00466DEMOFinal
2021T21DV05790Code enforcement caseComplian
2021T21DV02363Code enforcement caseVoid
2020T20DV01867ElectricalNoverify
2019T19CM08060COMBOFinal
2019T19DV04344Code enforcement caseNoverify
2017T17CM00391COMBOFinal
2016T16CM00884COMBOFinal
2014T14CM02429COMBOFinal
2014T14CM02431COMBOExpired
2014T14DV01185FireComplian
2013T13DV02301Code enforcement caseCancel
2013T13DV01644Code enforcement caseComplian
2011T11PL01773PLUMBFinal
2011T11PL01774PLUMBFinal
2011T11PL01775PLUMBFinal
2011T11PL01155PLUMBFinal
2011T11EL00728ELECTFinal
2008T08DV06508VegetationComplian
2007T07DV04672Code enforcement caseComplian
2007T07ME00235MECHFinal
2007T07EL00448ELECTExpired
2007T07DV01386Code enforcement caseComplian
2007T07PL00224PLUMBFinal
2006T06PL02302PLUMBFinal
2006T06FR02803FireComplete
2004T04PL01961PLUMBFinal
2003T03DV00489Code enforcement caseClosed
2003T03EL01052ELECTExpired
2002T02PL01840PLUMBFinal
2002T02PL01841PLUMBWithdrwn
2002T02PL01842PLUMBExpired
2002T02PL01843PLUMBExpired
2002T02VL01682Code enforcement caseClosed
2002T02VL01545Code enforcement caseClosed
2002T02EL00936ELECTFinal
2001T01VL02460Code enforcement caseComplian
1997T97PL00349PLUMBFinal

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 111041550 — 48 permits on file from 1997 to 2025 (19 commercial building, 12 plumb, 5 combo, 4 elect) and 23 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-22; the permit record is refreshed on a rolling cycle (at least every 45 days), and the assessor’s building file when the county publishes a new roll. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.