Electrical permit history — 3430 N Edith Bl
3430 N Edith Bl, Tucson — built 1973, with 10 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3430 N Edith Bl
Built 1973 — 1970s commercial stock · last permitted panel/service work 2020 (finaled)
Permanent link: Electrical permit history for 3430 N Edith Bl (aztucsonelectricalsolutions.com/property/11103113a/3430-n-edith-bl-tucson-az-85716) · Public records last checked 2026-08-16
- Parcel
- 11103113A
- Built
- 1973 (county record)
- Jurisdiction
- Tucson
- Zoning
- MH-1
- Assessor use
- Multiuse Or Miscellaneous Industrial
- Parcel size
- 0.43 acres
- Building area
- 5,753 sq ft (assessor record)
- Sewer
- Connection on file (1972, 2017) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2020 permit was finalized; the permit description states “N.437821 - TRANSFER 1 MAIN CABLE, 4 AERIAL SERVICE WIRES; INSTALL BONDING ASSEMBLY, CABLE TAG; REMOVE OLD POLE ADDRESS ON APPLICATION IS 3424 N EDITH BLVD”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2020 (6 years ago). City inspection record: last recorded inspection 2020-06-11; no approved final is shown. Contractor of record: TRAFFICADE SERVICE INC. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T20RW01100 — N.437821 - TRANSFER 1 MAIN CABLE, 4 AERIAL SERVICE WIRES; INSTALL BONDING ASSEMBLY, CABLE TAG; REMOVE OLD POLE ADDRESS ON APPLICATION IS 3424 N EDITH BLVD
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2008-10-01 | $60,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2020-02-21 (T20RW01100) — N.437821 - TRANSFER 1 MAIN CABLE, 4 AERIAL SERVICE WIRES; INSTALL BONDING ASSEMBLY, CABLE TAG; REMOVE OLD POLE ADDRESS ON APPLICATION IS 3424 N EDITH BLVD.
Permit history (10)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2020-02-21finaled | T20RW01100City permit record | ROWN.437821 - TRANSFER 1 MAIN CABLE, 4 AERIAL SERVICE WIRES; INSTALL BONDING ASSEMBLY, CABLE TAG; REMOVE OLD POLE ADDRESS ON APPLICATION IS 3424 N EDITH BLVD | Final | |
| 2019-06-11finaled | T19RW03267City permit record | ROWN.491821 - Transfer 1 main cable, 4 aerial service wires; Install bonding assembly, cable tag; Remove old pole. ADDRESS ON APPLICATION- 3424 N EDITH BL | Final | |
| 2019-03-07finaled | T19RW01245City permit record | ROWN.491821 - Transfer 1 main cable, 4 aerial service wires; Install bonding assembly, cable tag; Remove old pole. ADDRESS ON APPLICATION- 3424 N EDITH BL | Final | |
| 2017-10-31finaled | T17RW04840City permit record | ROWCHANGE OVERHEAD POWER TO UNDERGROUND IN DIRT SHOULDER | Final | |
| 2017-09-27finaled | T17RW04280City permit record | ROWTEP TO REPLACE 4 POLES AND ONE ANCHOR IN RIGHT OF WAY. NO MAJOR IMPACT NO SIDEWALK IMPACT; NE OF EDITH AND KLEINDALE | Final | |
| 2017-08-22finaled | T17RW03733City permit record | ROWDRIVE FROM PL TO BACK OF CURB/STREET APPROX 19' X 10' PER STANDARD DETAILS PAG 206 | Final | |
| 2017-02-14finaled | T17CM01201City permit record | COMBONEW SFR | C of o | |
| 2010-06-17finaled | T10MH00076City permit record | MHREPLACE:MOBILE HOME W/ELECTRIC | Final |
Show 2 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2008-05-30finaled | T08BU01008City permit record | DEMODEMO MOBILE HOME | Final | |
| 2008-05-30expired 2008-11-29 | T08MH00025City permit record | MHNEW MOBILE HOME (DEMO T08BU01008) | Withdrwn |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (1)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2015-08-12 | T15DV05901Code enforcement case | Code enforcement case | Noverify |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 11103113A — 10 permits on file from 2008 to 2020 (6 row, 2 mh, 1 combo, 1 demo) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.