Electrical permit history — 3888 E River Rd

3888 E River Rd, Tucson — built 1982, with 57 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3888 E River Rd

Built 1982 — 1980s commercial stock · last permitted panel/service work 2021 (permit expired without a confirmed final)

Parcel
11101035D
Built
1982 (assessor record)
Jurisdiction
Tucson
Zoning
PAD-8
Assessor use
Misc Commercial
Parcel size
27.62 acres
Building area
224,883 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
A — Special Flood Hazard Area (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2021 permit expired without a confirmed final status; the permit description states “Install 2 new 20amp electric circuits from existing 200amp single phase 40 circuit 120 / 240 volt pa”.

See the property

County aerial photograph centered on 3888 E River Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2021 permit specifies this work (the permit description states “Install 2 new 20amp electric circuits from existing 200amp single phase 40 circuit 120 / 240 volt pa”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T21CM05769 — Install 2 new 20amp electric circuits from existing 200amp single phase 40 circuit 120 / 240 volt pa
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00155 — New Sprinkler System Install
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    An ADU or casita was permitted in 2023, which means load has already been added to this property. Whether there is headroom left for anything more depends on how that was fed — a subpanel off the existing service, or its own.

  • Worth confirming

    Solar was permitted here in 2017. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Most recent permit on record for this parcel: 2026-07-15 (TF-FOP-0726-00962) — Tucson Hebrew Academy Pre School Classrooms 203 and 204.

Permit history (57)

Permit history for this parcel — 8 of 57 records
DateRecordWhatStatusValue
2026-07-15finaledTF-FOP-0726-00962City permit recordFire OperationalTucson Hebrew Academy Pre School Classrooms 203 and 204Complete
2026-05-21TF-FOP-0526-00710City permit recordPool / spaSummer Nights at the J is an opportunity for the community to enjoy good music, good company and good food by the pool. **VOID**Void
2026-05-21TF-FOP-0526-00711City permit recordPool / spaSummer Nights at the J is an opportunity for the community to enjoy good music, good company and good food by the pool. ***VOID***Void
2026-05-21expires 2026-08-31TF-FOP-0526-00712City permit recordFire OperationalJewish Community Center - Summer Nights at the JIssued
2025-08-01finaledTF-FOP-0825-01044City permit recordFire OperationalPre-K Classrooms 203 and 204 I-4Complete
2025-08-01TF-FOP-0825-01047City permit recordFire OperationalVOID - Duplicate Permit See Permit#TF-FOP-0825-01044 - Pre-K Classrooms 203 and 204Void
2025-06-30finaledTF-FOP-0625-00921City permit recordFire OperationalDPS Fire State Licensed Operational Permit Renewal.Complete
2025-06-24finaledTF-FOP-0625-00896City permit recordFire OperationalTucson Jewish Community CenterComplete

49 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2016-02-29T16DV01085Housing code violationHOMELESS CAMPSrecorded before 2023CANCEL
2010-05-17T10DV03205Housing code violationILLEGAL DUMPINGrecorded before 2023COMPLIAN

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11101035D — 57 permits on file from 2013 to 2026 (14 fire operational, 7 development package, 7 fireoper, 4 sign - annual portable) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.