Electrical permit history — 5801 E Grant Rd

5801 E Grant Rd, Tucson — built 1969, with 11 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5801 E Grant Rd

Built 1969 — 1960s commercial stock · 11 permits on record; no permitted panel/service or HVAC work among them

Parcel
11015232Q
Built
1969 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Cemetery Or Mausoleum For Profit
Parcel size
30.70 acres
Building area
4,990 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 5801 E Grant Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyPermitted — completion not confirmedA 2026 permit specifies this work (the permit description states “Modify existing fire sprinkler system & install new piping in new additions”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TF-FCP-0626-00418 — Modify existing fire sprinkler system & install new piping in new additions
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-06-25 (TF-FCP-0626-00418) — Modify existing fire sprinkler system & install new piping in new additions.

Permit history (11)

Permit history for this parcel — 8 of 11 records
DateRecordWhatStatusValue
2026-06-25expires 2027-01-22TF-FCP-0626-00418City permit recordAddition / alterationModify existing fire sprinkler system & install new piping in new additionsIssued
2025-12-08expires 2029-07-02TC-UTL-1225-00115City permit recordUtilitiesMinor DP for a building expansion in the NEC of the East Lawn Funeral HomeIssued
2025-10-06expires 2027-08-16TC-COM-1025-01809City permit recordPool / spaNEW GARAGE ADDITION, EXPANSION OF VENUE #2 AND REMODEL OF SELECT EXISTING SPACES. ASSOCIATED PERMIT - MINOR DP - TD-DEV-0825-00230In revision
2025-08-29expires 2029-07-02TD-DEV-0825-00230City permit recordDevelopment PackageRevision 1-Minor DP for a building expansion in the NEC of the East Lawn Funeral HomeIn revision
2025-07-24finaledTF-FCP-0725-00603City permit recordFire ConstructionJohnson Controls to add a cellular communicator to existing FACPComplete
2023-08-17finaledTR-UTL-0823-02295City permit recordRight-of-Way (ROW) - UtilityW.2986185-2: ACCESS OF EX HH 29784 FOR SPLICINGComplete
2023-08-15expired 2024-02-11TC-COM-0823-01994City permit recordAddition / alterationAddition of a service garage and outdoor patio. Internal TI to catering room off of patio. Note, associated DP; TD-DEV-0423-00220Withdrawn
2023-04-21expires 2026-09-17TD-DEV-0423-00220City permit recordAddition / alterationCustomer requested (REQ-0925-00537) to withdraw permitted DP in order to submit new DP plan. confirmed via email conversation with Theresa Hadley. She was offered the option to do a revision instead, but chose to withdraw the old DP and go through the process with a new DP. Addition of a two car garage accessed off of an existing garage as well as a walled patio with open trellise.Withdrawn
Show 3 older records
Permit history for this parcel — remaining 3 records
DateRecordWhatStatusValue
2023-03-03finaledTD-DEV-0323-00159City permit recordDevelopment PackageAdding open air pavilion to existing cemetery. Used Checklist for Minor Development Changes to Existing Commercial/Industrial SitesComplete
2022-12-22finaledTC-COM-1222-00359City permit recordCommercial BuildingAdding new open air pavilion to existing cemeteryComplete
2018-08-16finaledDP18-0199City permit recordDevelopment PackageE SITE/GRADING - NEW MASOLEUM- EAST LAWN PALMSComplete

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2022-11-23CE-VIO1122-00635Code enforcement caseCode enforcement caseClosed - resolved
2011-08-02T11DV06178Housing code violationWEEDSrecorded before 2023NOVERIFY

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11015232Q — 11 permits on file from 2018 to 2026 (3 addition / alteration, 3 development package, 1 utilities, 1 pool / spa) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.